ABSCI4H4S12

From Technical Support Wiki
Revision as of 15:12, 7 April 2017 by ACINT (talk | contribs)
Jump to: navigation, search

ABSCI4H4S09 is the 21 SEER 12,000 Btu outdoor unit of Blue Series 2.

Blue Series 2 condenser (12k)

Wiring Diagram

ABSCI4H4S12 Wiring Diagram

PCB Printed Diagram

ABSCI4H4S12 PCB Diagram
Number Description
1 Terminal of Compressor U Phase
2 Terminal of Compressor V Phase
3 Terminal of Compressor W Phase
4 Terminal of DC Fan
5 Terminal of Electronic Expansion Valve
6 Terminal of Compressor Overload Protection
7 Compressor Discharge Temperature Sensor
8 Terminal of AC Fan
9 Outdoor Pipe Temperature Sensor
10 Outdoor Ambient Temperature Sensor
11 Terminal of 4-Way Valve
12 Terminal of Heater
13 Communication Wire to Terminal Block
14 Terminal of Neutral Wire to Terminal Block
15 Terminal of Live Wire to Terminal Block
16 Terminal of Ground Wire
17 Terminal of Reactor
Terminal of Reactor




Exploded View and Parts List

ABSCI4H4S12 Exploded View
Number Part Name
1 Panel Parts
2 Propeller Fan Blade
3 Fan Motor
4 Motor Supporter Assy
5 Mounting Plate
6 Upper Board
7 Back Guard
8 Condenser Assembly
9 Base Holder Part
10 Clapboard
11 PFC Inductance
12 Pipe Assy
13 Compressor
14 Compressor Connect Wire
15 Capillary Assembly
16 2-way Valve
17 3-Way Valve
18 Right Side Board
19 Wiring Distribution Cover Assy
20 Connecting Board
21 Wire Terminal Board
22 Electric Box
23 Outdoor Main Control Board Component
24 Electric Box Cover
25 Temperature Sensor
26 Temperature Sensor
27 Temperature Sensor
28 Sensor Mounting Plate

Piping Sizes

Liquid Side Gas Side
1/4" 3/8"

Accessories