ABXCI4H4S24
From Technical Support Wiki
Revision as of 14:13, 11 July 2019 by ACINT (talk | contribs) (Created page with "ABXCI4H4S24 is the 21 SEER 24,000 Btu outdoor unit of ''Blue Series 3''. right|thumb|''Blue Series 3'' condenser (24k) == Wiring Diagram == File...")
ABXCI4H4S24 is the 21 SEER 24,000 Btu outdoor unit of Blue Series 3.
Wiring Diagram
PCB Printed Diagram
File:Blue3-23k-ODU-PCB.jpg
ABXCI4H4S24 PCB Diagram
| Number | Description |
|---|---|
| 1 | Terminal of Reactor |
| 2 | Terminal of Compressor (White) |
| 3 | Terminal of DC Fan (White) |
| 4 | Heat Sink Temperature Sensor (White) |
| 5 | Pressure Protector (Black) |
| 6 | Compressor Discharge Temperature Sensor (Yellow) |
| 7 | Outdoor Ambient Temperature Sensor (White) |
| 8 | Outdoor Pipe Temperature Sensor (Red) |
| 9 | Terminal of Compressor Overload Protector (White) |
| 10 | Terminal of Electronic Expansion Valve (White) |
| 11 | DRED Function |
| 12 | Terminal of AC Fan (White) |
| 13 | Cool Valve Terminal |
| 14 | Heater Terminal |
| 15 | 4-way Valve Terminal (Black) |
| 16 | Terminal of Signal Wire to Terminal Block |
| 17 | Terminal of Live Wire to Terminal Block |
| 18 | Terminal of Neutral Wire to Terminal Block |
Exploded View and Parts List
| Number | Part Name |
|---|---|
| 1 | Panel Parts |
| 2 | Propeller Fan Blade |
| 3 | Fan Motor |
| 4 | Motor Supporter Assy |
| 5 | Mounting Plate |
| 6 | Upper Board |
| 7 | Back Guard |
| 8 | Condenser Assembly |
| 9 | Base Holder Part |
| 10 | Clapboard |
| 11 | PFC Inductance |
| 12 | Compressor Tube Assembly (cooling Only Models) |
| 13 | Compressor |
| 14 | Compressor Connect Wire |
| 15 | Electronic Expansion Valve Assy |
| 16 | 2-way Valve |
| 17 | 3-Way Valve |
| 18 | Right Side Board |
| 19 | Main Controlling Board Component |
| 20 | Wired Terminal Board |
| 21 | Discharge Temperature Sensor |
| 22 | Temperature Sensor |
| 23 | Ambient Temperature Sensor |
Piping Sizes
| Liquid Side | Gas Side |
|---|---|
| 3/8" | 5/8" |