ABXCI4H4S24 is the 21 SEER 24,000 Btu outdoor unit of Blue Series 3.

Blue Series 3 condenser (24k)

Wiring Diagram

ABXCI4H4S24 Wiring Diagram

PCB Printed Diagram

ABXCI4H4S24 PCB Diagram
Number Description
1 Terminal of Reactor
2 Terminal of Compressor (White)
3 Terminal of DC Fan (White)
4 Heat Sink Temperature Sensor (White)
5 Pressure Protector (Black)
6 Compressor Discharge Temperature Sensor (Yellow)
7 Outdoor Ambient Temperature Sensor (White)
8 Outdoor Pipe Temperature Sensor (Red)
9 Terminal of Compressor Overload Protector (White)
10 Terminal of Electronic Expansion Valve (White)
11 DRED Function
12 Terminal of AC Fan (White)
13 Cool Valve Terminal
14 Heater Terminal
15 4-way Valve Terminal (Black)
16 Terminal of Signal Wire to Terminal Block
17 Terminal of Live Wire to Terminal Block
18 Terminal of Neutral Wire to Terminal Block




Exploded View and Parts List

ABXCI4H4S24 Exploded View
Number Part Name
1 Handle
2 Panel Parts
3 Base Holder Part
4 PFC Inductance
6 Propeller Fan Blade
7 Condenser Assembly
8 Fan Motor
9 Motor Supporter
10 Mounting Plate
11 Compressor
12 Compressor Overload Protector
13 5/8" 3-Way Valve
14 3/8" 2-Way Valve
15 Electronic Expansion Valve Assembly
16 Controller Component
17 Clapboard Part
18 Back Guard
19 Valve Seat
20 Right Side Board Part
21 Handle
22 4-Way Reversing Valve Assembly
23 4-Way Valve
24 4-Way Valve Coil
25 Wire Terminal Board
27 Electric Box
28 Wiring Distribution Cover
29 Temperature Sensor
30 Temperature Sensor
31 Temperature Sensor
32 Strong Electricity Connect Wire
33 Top Plate Part

Piping Sizes

Liquid Side Gas Side
3/8" 5/8"

Accessories