ASKCI4H4R18

From Technical Support Wiki
Revision as of 12:46, 16 June 2015 by ACINT (talk | contribs)
Jump to: navigation, search

ASKCI4H4R18 is the 17-16 SEER 18,000 Btu outdoor unit of the Sky Split Series.

Sky Split Series condenser (18k)

Wiring Diagram

ASKCI4H4R18 Wiring Diagram

PCB Printed Diagram

ASKCI4H4R18 Main Board Diagram
Number Description
1 Live wire input
2 Neutral wire input
3 Control power output [1-DC bus voltage, 3-GND]
4 DC Fan Motor 2
5 DC Fan Motor 1
6 Control power output [1-GND 2-18V, 3-15V]
7 Communication line [1-3.3V, 2-TX, 3-RX, 4-GND]
8 Communication line [1-pin GND, 2-pin B and 3-pin A]
9 Communication line [1-pin+12V, 2-pin B, 3-pin A, 4-pin GND]
10 High pressure switch for fan speed adjustment
11 High pressure switch for system protection
12 Low pressure switch for system protection
13 Compressor overload protection
14 Temperature Sensor
15 Electronic expansion valve line
16 Compressor electrical heater
17 Chassis electrical heater
18 4-way valve













Exploded View and Parts List

ACZCI4H4R09 Exploded View
Number Part Name
1 Front Grill
2 Cabinet
3 Axial Flow Fan Sub-Assy
4 Fan Motor
5 Left Side Plate
6 Motor Support
7 Clapboard
8 Compressor and Fittings
9 Compressor Overload Protector (External)
10 Electric Heater (Compressor)
11 4-Way Valve Assy
12 Top Cover Sub-Assy
13 Right Side Plate Sub-Assy
14 Condenser Assy
15 Handle
16 Valve Support
17 Drainage Joint
18 Cut Off Valve Assy
19 Chassis Sub-Assy
20 Capacitor CBB61
21 Temperature Sensor
22 Main Board
23 Electric Box Sub-Assy
24 Electric Box Assy

Piping Sizes

Liquid Side Gas Side
1/4" 3/8"

Accessories