ASKCI4H4R18
From Technical Support Wiki
ASKCI4H4R18 is the 17-16 SEER 18,000 Btu outdoor unit of the Sky Split Series.
Wiring Diagram
PCB Printed Diagram
Number | Description |
---|---|
1 | Live wire input |
2 | Neutral wire input |
3 | Control power output [1-DC bus voltage, 3-GND] |
4 | DC Fan Motor 2 |
5 | DC Fan Motor 1 |
6 | Control power output [1-GND 2-18V, 3-15V] |
7 | Communication line [1-3.3V, 2-TX, 3-RX, 4-GND] |
8 | Communication line [1-pin GND, 2-pin B and 3-pin A] |
9 | Communication line [1-pin+12V, 2-pin B, 3-pin A, 4-pin GND] |
10 | High pressure switch for fan speed adjustment |
11 | High pressure switch for system protection |
12 | Low pressure switch for system protection |
13 | Compressor overload protection |
14 | Temperature Sensor |
15 | Electronic expansion valve line |
16 | Compressor electrical heater |
17 | Chassis electrical heater |
18 | 4-way valve |
Exploded View and Parts List
Number | Part Name |
---|---|
1 | Front Grill |
2 | Front Panel |
3 | Axial Flow Fan |
4 | Chassis Sub-Assy |
5 | Electrical Heater |
6 | Drainage Hole Cap |
7 | Drainage Connector |
8 | Compressor Overload Protector (External) |
9 | Compressor Gasket |
10 | Compressor and Fittings |
11 | Cut Off Valve |
12 | Cut Off Valve Sub-Assy |
13 | Cut Off Valve |
14 | Cut Off Valve Sub-Assy |
15 | Pressure Protect Switch |
16 | Valve Support Assy |
17 | Right Side Plate |
18 | Silencer |
19 | Handle Assy |
20 | Strainer |
21 | Strainer |
22 | Strainer |
23 | Electronic Expansion Valve |
24 | Electric Expand Valve Fitting |
25 | 4-Way Valve |
26 | Magnet Coil |
27 | Inductance |
28 | Rear Grill |
29 | Clapboard Sub-Assy |
30 | Condenser Assy |
31 | Terminal Board |
32 | Terminal Board |
33 | Supporting Board (Condenser) |
34 | Coping |
35 | Electric Box Assy |
36 | Main Board |
37 | Main Board |
38 | Filter Board |
39 | Radiator |
40 | Left Handle |
41 | Left Side Plate |
42 | Motor Support Assy |
43 | Fan Motor |
44 | Temperature Sensor |
Piping Sizes
Liquid Side | Gas Side |
---|---|
1/4" | 1/2" |