ASKCI4H4R18 is the 17-16 SEER 18,000 Btu outdoor unit of the Sky Split Series.

Sky Split Series condenser (18k)

Wiring Diagram

ASKCI4H4R18 Wiring Diagram

PCB Printed Diagram

ASKCI4H4R18 Main Board Diagram
Number Description
1 Live wire input
2 Neutral wire input
3 Control power output [1-DC bus voltage, 3-GND]
4 DC Fan Motor 2
5 DC Fan Motor 1
6 Control power output [1-GND 2-18V, 3-15V]
7 Communication line [1-3.3V, 2-TX, 3-RX, 4-GND]
8 Communication line [1-pin GND, 2-pin B and 3-pin A]
9 Communication line [1-pin+12V, 2-pin B, 3-pin A, 4-pin GND]
10 High pressure switch for fan speed adjustment
11 High pressure switch for system protection
12 Low pressure switch for system protection
13 Compressor overload protection
14 Temperature Sensor
15 Electronic expansion valve line
16 Compressor electrical heater
17 Chassis electrical heater
18 4-way valve













Exploded View and Parts List

ASKCI4H4R18 Exploded View
Number Part Name
1 Front Grill
2 Front Panel
3 Axial Flow Fan
4 Chassis Sub-Assy
5 Electrical Heater
6 Drainage Hole Cap
7 Drainage Connector
8 Compressor Overload Protector (External)
9 Compressor Gasket
10 Compressor and Fittings
11 Cut Off Valve
12 Cut Off Valve Sub-Assy
13 Cut Off Valve
14 Cut Off Valve Sub-Assy
15 Pressure Protect Switch
16 Valve Support Assy
17 Right Side Plate
18 Silencer
19 Handle Assy
20 Strainer
21 Strainer
22 Strainer
23 Electronic Expansion Valve
24 Electric Expand Valve Fitting
25 4-Way Valve
26 Magnet Coil
27 Inductance
28 Rear Grill
29 Clapboard Sub-Assy
30 Condenser Assy
31 Terminal Board
32 Terminal Board
33 Supporting Board (Condenser)
34 Coping
35 Electric Box Assy
36 Main Board
37 Main Board
38 Filter Board
39 Radiator
40 Left Handle
41 Left Side Plate
42 Motor Support Assy
43 Fan Motor
44 Temperature Sensor

Piping Sizes

Liquid Side Gas Side
1/4" 1/2"

Accessories