ASKCI4H4R18
From Technical Support Wiki
ASKCI4H4R18 is the 17-16 SEER 18,000 Btu outdoor unit of the Sky Split Series.
Wiring Diagram
PCB Printed Diagram
Number | Description |
---|---|
1 | Live wire input |
2 | Neutral wire input |
3 | Control power output [1-DC bus voltage, 3-GND] |
4 | DC Fan Motor 2 |
5 | DC Fan Motor 1 |
6 | Control power output [1-GND 2-18V, 3-15V] |
7 | Communication line [1-3.3V, 2-TX, 3-RX, 4-GND] |
8 | Communication line [1-pin GND, 2-pin B and 3-pin A] |
9 | Communication line [1-pin+12V, 2-pin B, 3-pin A, 4-pin GND] |
10 | High pressure switch for fan speed adjustment |
11 | High pressure switch for system protection |
12 | Low pressure switch for system protection |
13 | Compressor overload protection |
14 | Temperature Sensor |
15 | Electronic expansion valve line |
16 | Compressor electrical heater |
17 | Chassis electrical heater |
18 | 4-way valve |
Exploded View and Parts List
Number | Part Name |
---|---|
1 | Front Grill |
2 | Cabinet |
3 | Axial Flow Fan Sub-Assy |
4 | Fan Motor |
5 | Left Side Plate |
6 | Motor Support |
7 | Clapboard |
8 | Compressor and Fittings |
9 | Compressor Overload Protector (External) |
10 | Electric Heater (Compressor) |
11 | 4-Way Valve Assy |
12 | Top Cover Sub-Assy |
13 | Right Side Plate Sub-Assy |
14 | Condenser Assy |
15 | Handle |
16 | Valve Support |
17 | Drainage Joint |
18 | Cut Off Valve Assy |
19 | Chassis Sub-Assy |
20 | Capacitor CBB61 |
21 | Temperature Sensor |
22 | Main Board |
23 | Electric Box Sub-Assy |
24 | Electric Box Assy |
Piping Sizes
Liquid Side | Gas Side |
---|---|
1/4" | 3/8" |