ABSCI4H4S09
From Technical Support Wiki
ABSCI4H4S09 is the 22 SEER 9,000 Btu outdoor unit of Blue Series 2.
Wiring Diagram
PCB Printed Diagram
| Number | Description |
|---|---|
| 1 | Terminal of Compressor U Phase |
| 2 | Terminal of Compressor V Phase |
| 3 | Terminal of Compressor W Phase |
| 4 | Terminal of DC Fan |
| 5 | Terminal of Electronic Expansion Valve |
| 6 | Terminal of Compressor Overload Protection |
| 7 | Compressor Discharge Temperature Sensor |
| 8 | Terminal of AC Fan |
| 9 | Outdoor Pipe Temperature Sensor |
| 10 | Outdoor Ambient Temperature Sensor |
| 11 | Terminal of 4-Way Valve |
| 12 | Terminal of Heater |
| 13 | Communication Wire to Terminal Block |
| 14 | Terminal of Neutral Wire to Terminal Block |
| 15 | Terminal of Live Wire to Terminal Block |
| 16 | Terminal of Ground Wire |
| 17 | Terminal of Reactor |
| Terminal of Reactor |
Exploded View and Parts List
| Number | Part Name |
|---|---|
| 1 | Front Grill |
| 2 | Cabinet |
| 3 | Axial Flow Fan Sub-Assy |
| 4 | Fan Motor |
| 5 | Left Side Plate |
| 6 | Motor Support |
| 7 | Clapboard |
| 8 | Compressor and Fittings |
| 9 | Compressor Overload Protector (External) |
| 10 | Electric Heater (Compressor) |
| 11 | 4-Way Valve Assy |
| 12 | Top Cover Sub-Assy |
| 13 | Right Side Plate Sub-Assy |
| 14 | Condenser Assy |
| 15 | Handle |
| 16 | Valve Support |
| 17 | Drainage Joint |
| 18 | Cut Off Valve Assy |
| 19 | Chassis Sub-Assy |
| 20 | Capacitor CBB61 |
| 21 | Temperature Sensor |
| 22 | Main Board |
| 23 | Electric Box Sub-Assy |
| 24 | Electric Box Assy |
Piping Sizes
| Liquid Side | Gas Side |
|---|---|
| 1/4" | 3/8" |