ACZEM4H4R18 is the 15 SEER 18,000 Btu indoor unit of the Blue Series.

Blue Series evaporator (18k)

Remote Control

Remote Control
# Name Description
1 ON/OFF Press to start or stop operation.
2 MODE Press to select operation mode (Auto/Cool/Dry/Fan/Heat).
3 + (Raise) Press to raise the temperature setting.
3 - (Lower) Press to lower the temperature setting.
4 FAN Press to set fan speed. Rotates between Auto and Speeds 1-4.
5 SWING Press to set swing angle.
6 SLEEP Press to turn on sleep function.
7 TIMER Manage the on and off timer with this button.

Wiring Diagram

ACZEM4H4R18 Wiring Diagram

PCB Printed Diagram

ACZEM4H4R18 PCB Printed Diagram
Number Description
1 Live wire interface
2 Fuse
3 Neutral wire interface
4 PG motor interface
5 Communication port of neutral wire and live wire
6 Auto button
7 Up & down swing interface
8 PG feedback interface
9 Display interface
10 Ambient temperature sensor
11 Tube temperature sensor









Exploded View and Parts List

ACZEM4H4R12 Exploded View
Number Part Name
1 Front Panel Sub-Assy
2 Filter Sub-Assy
3 Front Case Sub-Assy
4 Guide Louver
5 Axile Bush
6 Rear Grill
7 Air Louver 2
8 Helicoid Tongue
9 Left Axile Bush
10 Rear Case Assy
11 Ring of Bearing
12 O-Gasket Sub-Assy of Bearing
13 Cross Flow Fan
14 Evaporator Support
15 Evaporator Assy
16 Motor Press Plate
17 Wall Mounting Frame
18 Drainage Hose
19 Fan Motor
20 Connecting Pipe Clamp
21 Rubber Plug (Water Tray)
22 Cable Cross Plate
23 Stepping Motor
24 Crank
25 Screw Cover
26 Air Louver 1
27 Electric Box
28 Magnetic Ring
29 Terminal Board
30 Electric Box Cover 2
31 Main Board
32 Capacitor CBB61
33 Jumper
34 Shield Cover of Electric Box
35 Shield Cover of Electric Box Sub-Assy
36 Lower Shield Sub-Assy of Electric Box
37 Electric Box Assy
38 Display Board
39 Ambient Temperature Sensor
40 Remote Controller