Blue Hyper Series 18K & 24K Specs

From Technical Support Wiki
Revision as of 16:00, 24 April 2023 by ACINT (talk | contribs) (Created page with "{| class="wikitable" |- ! scope="col" colspan="2" | Parameter ! scope="col" | Unit ! scope="col" colspan="2" | Value |- ! scope="row" colspan="2" | Model | | ABHCI4H4S18/ABHE...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search
Parameter Unit Value
Model ABHCI4H4S18/ABHEM4H4S18 ABHCI4H4S24/ABHEM4H4S24
Power Supply Rated Voltage V 208/230 208/230
Rated Frequency Hz 60 60
Phases 1 1
Cooling Rated Capacity (Min/Max) BTU/h 18000(4500~20000) 24000 (5500~25000)
Input W 1360 1920
Rated Current A 6.0 8.5
EER2 BTU/w 13.2 12.5
SEER1 BTU/w 20.5 21
SEER2 BTU/w 20.5 21
Heating at 47°F Rated Capacity (Min/Max) BTU/h 19000 (5500~23000) 26000 (6000~27000)
Input W 1620 2500
Rated Current A 7.2 11.2
COP W/W 3.51 3.05
HSPF1 BTU/w 10.5 11.5
HSPF2 BTU/w 9.5 10
Heating at 17°F(-8.3°C) Rated Capacity (Min/Max) BTU/h 10500(8000~17500) 15500(10000~21000)
Heating at 5°F(-15°C) Rated Capacity (Min/Max) BTU/h 13300(8000~15500) 18200(10000~22800)
Heating at -5°F(-20°C) Heating Capacity (Min/Max) BTU/h 15000 19500
Heating at -13°F(-25°C) Heating Capacity (Min/Max) BTU/h 14000 15000
Heating at -22°F(-30°C) Rated Capacity (Min/Max) BTU/h 9000~12000 10000~15000
COP at 5°F(-15°C) W/W 1.85 1.75
Minimum Circuit Ampacity A 9 9
Max Fuse A 15 15
Compressor Type ROTARY ROTARY
Brand GMCC GMCC
Indoor Fan Motor Model DC DC
Indoor Air Flow (H/M/L) m3/h 620 / 520 / 430 640 / 550 / 430
Indoor Air Flow (H/M/L) CFM 365 / 306 / 253 377 / 324 / 253
Indoor Sound Pressure (SH/H/M/L/SL) dB(A) 42/39/35/32/29 42/40/36/32/29
Indoor Unit Dimension (WxDxH) mm 850×270×206 850×270×206
Dimension (WxDxH) inch 33 1/2x10 5/8 x8 1/8 33 1/2x10 5/8 x8 1/8
Packing (WxDxH) mm 900×335×260 900×335×260
Packing (WxDxH) inch 35 7/16x13 3/16x10 2/8 35 7/16x13 3/16x10 2/8
Net/Gross Weight kg 8.5/10.5 8.5/10.5
Net/Gross Weight lbs 18.7/23.1 18.7/23.1
Outdoor Fan Motor Model DC DC
Outdoor Air Flow m3/h 1900 1900
Outdoor Air Flow CFM 1120 1120
Outdoor Noise Level dB(A) 53 53
Outdoor Unit Dimension (WxDxH) mm 810x280x585 810x280x585
Dimension (WxDxH) inch 31 7/8x11x23 31 7/8x11x23
Packing (WxDxH) mm 940x385x640 940x385x640
Packing (WxDxH) inch 37x15 3/16x25 3/16 37x15 3/16x25 3/16
Net/Gross Weight kg 33/36 33/36
Net/Gross Weight lbs 72.6/79.2 72.6/79.2
Refrigerant Type R410A R410A
Design Pressure PSIG 550/340PSIG 550/340PSIG
Refrigerant Piping Liquid Side/ Gas Side mm(inch) Φ6.35/Φ9.52(1/4"/3/8") Φ6.35/Φ9.52(1/4"/3/8")
Max. Refrigerant Pipe Length m 20 20
Max. Refrigerant Pipe Length ft 66 66
Max. Difference In Level m 10 10
Max. Difference In Level ft 33 33
Operation Temperature Indoor (Cooling/Heating) °C 17~32/0~30 17~32/0~30
Indoor (Cooling/Heating) °F 62~90/32~86 62~90/32~86
Outdoor (Cooling/Heating) °C -15~46/-30~24 -15~46/-30~24
Outdoor (Cooling/Heating) °F 5~115/-22~75 5~115/-22~75