Blue Hyper Series 9K & 12K Specs
From Technical Support Wiki
| Parameter | Unit | Value | ||
|---|---|---|---|---|
| Model | ABHCI4H4S09/ABHEM4H4S09 | ABHCI4H4S12/ABHEM4H4S12 | ||
| Power Supply | Rated Voltage | V | 208/230 | 208/230 |
| Rated Frequency | Hz | 60 | 60 | |
| Phases | 1 | 1 | ||
| Cooling | Rated Capacity (Min/Max) | BTU/h | 9000 (3000~12000) | 12000 (3000~14000) |
| Input | W | 620 | 940 | |
| Rated Current | A | 2.8 | 4.3 | |
| EER2 | BTU/w | 14.5 | 12.7 | |
| SEER1 | BTU/w | 24.5 | 23 | |
| SEER2 | BTU/w | 25.5 | 23.5 | |
| Heating at 47°F | Rated Capacity (Min/Max) | BTU/h | 10000 (3000~14000) | 12000 (3000~16000) |
| Input | W | 720 | 940 | |
| Rated Current | A | 3.2 | 4.3 | |
| COP | W/W | 4.07 | 3.74 | |
| HSPF1 | BTU/w | 12 | 11 | |
| HSPF2 | BTU/w | 10.5 | 9.5 | |
| Heating at 17°F(-8.3°C) | Rated Capacity (Min/Max) | BTU/h | 5500(4500~9500) | 6800(5000~11500) |
| Heating at 5°F(-15°C) | Rated Capacity (Min/Max) | BTU/h | 7000(4000~8600) | 8400(5000~10000) |
| Heating at -5°F(-20°C) | Heating Capacity (Min/Max) | BTU/h | 8500 | 9500 |
| Heating at -13°F(-25°C) | Heating Capacity (Min/Max) | BTU/h | 7000 | 7500 |
| Heating at -22°F(-30°C) | Rated Capacity (Min/Max) | BTU/h | 4000~5500 | 5000~6000 |
| COP at 5°F(-15°C) | W/W | 2.2 | 1.98 | |
| Minimum Circuit Ampacity | A | 9 | 9 | |
| Max Fuse | A | 15 | 15 | |
| Compressor | Type | ROTARY | ROTARY | |
| Brand | GMCC | GMCC | ||
| Indoor Fan Motor | Model | DC | DC | |
| Indoor Air Flow (H/M/L) | m3/h | 620 / 520 / 430 | 640 / 550 / 430 | |