Blue Hyper Series 9K & 12K Specs

From Technical Support Wiki
Revision as of 15:19, 24 April 2023 by ACINT (talk | contribs)
Jump to: navigation, search
Parameter Unit Value
Model ABHCI4H4S09/ABHEM4H4S09 ABHCI4H4S12/ABHEM4H4S12
Power Supply Rated Voltage V 208/230 208/230
Rated Frequency Hz 60 60
Phases 1 1
Cooling Rated Capacity (Min/Max) BTU/h 9000 (3000~12000) 12000 (3000~14000)
Input W 620 940
Rated Current A 2.8 4.3
EER2 BTU/w 14.5 12.7
SEER1 BTU/w 24.5 23
SEER2 BTU/w 25.5 23.5
Heating at 47°F Rated Capacity (Min/Max) BTU/h 10000 (3000~14000) 12000 (3000~16000)
Input W 720 940
Rated Current A 3.2 4.3
COP W/W 4.07 3.74
HSPF1 BTU/w 12 11
HSPF2 BTU/w 10.5 9.5
Heating at 17°F(-8.3°C) Rated Capacity (Min/Max) BTU/h 5500(4500~9500) 6800(5000~11500)
Heating at 5°F(-15°C) Rated Capacity (Min/Max) BTU/h 7000(4000~8600) 8400(5000~10000)
Heating at -5°F(-20°C) Heating Capacity (Min/Max) BTU/h 8500 9500
Heating at -13°F(-25°C) Heating Capacity (Min/Max) BTU/h 7000 7500
Heating at -22°F(-30°C) Rated Capacity (Min/Max) BTU/h 4000~5500 5000~6000
COP at 5°F(-15°C) W/W 2.2 1.98
Minimum Circuit Ampacity A 9 9
Max Fuse A 15 15
Compressor Type ROTARY ROTARY
Brand GMCC GMCC
Indoor Fan Motor Model DC DC
Indoor Air Flow (H/M/L) m3/h 620 / 520 / 430 640 / 550 / 430