TD Prime Heat Pump Specs

From Technical Support Wiki
Revision as of 14:46, 7 April 2022 by ACINT (talk | contribs)
Jump to: navigation, search

Specification Table of the Heat Pump TD Prime ducted units.

Outdoor Model ATDCI4H4G24 ATDCI4H4G36 ATDCI4H4G48 ATDCI4H4G60
Outdoor Power Supply V/Ph/Hz 208-203V/1Ph/60Hz 208-203V/1Ph/60Hz 208-203V/1Ph/60Hz 208-203V/1Ph/60Hz
Cooling Capacity Btu/h 24000 34500 47000 56000
W 7033 10110 13774 16411
EER Btu/Wh 11.6 11.6 11.6 10.8
SEER Btu/Wh 17.5 17.5 17.5 17.5
Heating Capacity Btu/h 24000 34000 46500 55000
W 7033 10110 13627 16118
COP Btu/Wh 13.0 11.9 12.9 11.5
HSPF Btu/Wh 9.5 9.0 9.5 9.5
Min. Circuit Ampacity (IU/OU) A 3.5/17.7 5.1/24.2 7.5/31.9 7.5/36.5
Max Fuse/Breaker (IU/OU) A 15/30 15/40 15/50 15/60
Cooling Operation Range °F 64~118 64~118 64~118 64~118
°C 18~47 18~47 18~47 18~47
Cooling Operation Range °F 5~109 5~109 5~109 5~109
°C -15~42 -15~42 -15~42 -15~42
Compressor Type GMCC Twin-rotary DC Mitsubishi Twin-rotary DC
Outdoor Dimension Unit (WxHxD) inch 29x25x29 29x25x29 29x33x29 29x33x29
Packaging (WxHxD) inch 30x26x30 30x26x30 30x35x30 30x35x30
Indoor Model ATDEM4H4G24 ATDEM4H4G36 ATDEM4H4G48 ATDEM4H4G60
Cooling Capacity Btu/h 24000 34500 47000 56000
SEER 17.5 17.5 17.5 17.5
Heating Capacity Btu/h 24000 34000 46500 55000
HSPF 9.5 9.0 9.5 9.5
Indoor Max Current A 0.91 1.35 2.39 2.43
Indoor Air Flow CFM 780 1300 1500 1750
m3/h 1325 2208 2548 2973
Indoor Noise Level dB(A) 63 66 67 68
ESP Pa 25 37 50 50
Indoor Dimension Unit (WxHxD) inch 20x46x22 20x46x22 22x53x24 22x53x24
Packaging (WxHxD) inch 23x48x26 23x48x26 26x55x28 26x55x28