ABXCI4H4S12

From Technical Support Wiki
Revision as of 14:05, 11 July 2019 by ACINT (talk | contribs)
Jump to: navigation, search

ABXCI4H4S12 is the 21 SEER 12,000 Btu outdoor unit of Blue Series 3.

Blue Series 3 condenser (12k)

Wiring Diagram

ABXCI4H4S12 Wiring Diagram

PCB Printed Diagram

ABSXI4H4S12 PCB Diagram
Number Description
1 Terminal of Compressor U/V/W Phase
2 Terminal of Reactor (optional)
3 Terminal of Neutral Wire, connect to the terminal panel 1(N)
4 Terminal of Live Wire, connect to the terminal panel 2(L)
5 Terminal of Signal Wire, connect to the terminal panel 3(SI)
6 Terminal of AC Fan
7 Cool Valve Terminal
8 Heater Terminal
9 4-way Valve Terminal
10 Terminal of DC Fan
11 Terminal of Electronic Expansion Valve
12 Outdoor Ambient Temperature Sensor
13 Outdoor Pipe Temperature Sensor
14 Compressor Discharge Temperature Sensor
15 Terminal of Compressor Overload Protector
16 Over Pressure Sensor
17 DRED Function




Exploded View and Parts List

ABSCI4H4S12 Exploded View
Number Part Name
1 Panel Parts
2 Propeller Fan Blade
3 Fan Motor
4 Motor Supporter Assy
5 Mounting Plate
6 Upper Board
7 Back Guard
8 Condenser Assembly
9 Base Holder Part
10 Clapboard
11 PFC Inductance
12 Pipe Assy
13 Compressor
14 Compressor Connect Wire
15 Capillary Assembly
16 2-way Valve
17 3-Way Valve
18 Right Side Board
19 Wiring Distribution Cover Assy
20 Connecting Board
21 Wire Terminal Board
22 Electric Box
23 Outdoor Main Control Board Component1
24 Electric Box Cover
25 Temperature Sensor
26 Temperature Sensor
27 Temperature Sensor
28 Sensor Mounting Plate

1ODU control board had a revision in March 2018.

Piping Sizes

Liquid Side Gas Side
1/4" 3/8"

Accessories