ABXCI4H4S09

From Technical Support Wiki
Revision as of 13:57, 11 July 2019 by ACINT (talk | contribs) (Created page with "ABXCI4H4S09 is the 22 SEER 9,000 Btu outdoor unit of ''Blue Series 3''. right|thumb|''Blue Series 3'' condenser (9k) == Wiring Diagram == File:B...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

ABXCI4H4S09 is the 22 SEER 9,000 Btu outdoor unit of Blue Series 3.

Blue Series 3 condenser (9k)

Wiring Diagram

ABXCI4H4S09 Wiring Diagram

PCB Printed Diagram

ABXCI4H4S09 PCB Diagram
Number Description
1 Terminal of Compressor U Phase
2 Terminal of Compressor V Phase
3 Terminal of Compressor W Phase
4 Terminal of DC Fan
5 Terminal of Electronic Expansion Valve
6 Terminal of Compressor Overload Protection
7 Compressor Discharge Temperature Sensor
8 Terminal of AC Fan
9 Outdoor Pipe Temperature Sensor
10 Outdoor Ambient Temperature Sensor
11 Terminal of 4-Way Valve
12 Terminal of Heater
13 Communication Wire to Terminal Block
14 Terminal of Neutral Wire to Terminal Block
15 Terminal of Live Wire to Terminal Block
16 Terminal of Ground Wire
17 Terminal of Reactor
Terminal of Reactor




Exploded View and Parts List

ABSCI4H4S09 Exploded View
Number Part Name
1 Panel Parts
2 Propeller Fan Blade
3 Fan Motor
4 Motor Supporter
5 Mounting Plate
6 Upper Board
7 Back Guard
8 Condenser Assembly
9 Base Holder Part
10 Clapboard
11 PFC Inductance
12 Compressor Tube Assy (Cooling Only Models)
13 Compressor
14 Compressor Connect Wire
15 Valve Seat
16 Capillary Assembly
17 2-Way Valve
18 3-Way Valve
19 Right Side Board
20 Wiring Distribution Cover Assy
21 Fixed Board
22 Electric Box
23 Connecting Board
24 Wire Terminal Board
25 Outdoor Main Control Board Component
26 Electric Box Cover
27 Temperature Sensor
28 Temperature Sensor
29 Temperature Sensor

Piping Sizes

Liquid Side Gas Side
1/4" 3/8"

Accessories