User contributions
- 20:59, 11 November 2013 diff hist +193 A16EM4H4R09
- 20:55, 11 November 2013 diff hist +1,812 A16EM4H4R09 →Error Codes
- 20:31, 11 November 2013 diff hist +30 A16EM4H4R09 →Error Codes
- 20:29, 11 November 2013 diff hist -4 A16EM4H4R09 →Error Codes
- 20:29, 11 November 2013 diff hist +341 N A16EM4H4R09 Created page with "A16EM4H4R09 is the 16 SEER, 9,000 Btu indoor unit for the Air-Con Multi Splits. == Error Codes == {| class = "wikitable" | rowspan="2"|Malfunction Name | rowspan="2"|Dual-8 ..."
- 19:43, 11 November 2013 diff hist +229 Air-Con Multi Split
- 19:16, 11 November 2013 diff hist +68 Air-Con Multi Split
- 19:15, 11 November 2013 diff hist 0 N File:Multi-featured.png current
- 19:14, 11 November 2013 diff hist -4,705 Air-Con Multi Split Replaced content with "This is the support page for the Air-Con multi split line. Here you will find information pertaining to common issues with the multi split units. == Indoor Units == * A..."
- 19:14, 11 November 2013 diff hist 0 A16CM4H4R36
- 19:13, 11 November 2013 diff hist +5,774 N A16CM4H4R39 Created page with "A16CM4H4R39 is the 16 SEER, 36,000 Btu dual zone multi split unit. == Malfunction Indicator == Note: When several malfunctions occur at the same time, they will be displayed..."
- 19:12, 11 November 2013 diff hist +5,774 N A16CM4H4R36 Created page with "A16CM4H4R36 is the 16 SEER, 36,000 Btu dual zone multi split unit. == Malfunction Indicator == Note: When several malfunctions occur at the same time, they will be displayed..."
- 19:12, 11 November 2013 diff hist +5,774 N A16CM4H4R24 Created page with "A16CM4H4R24 is the 16 SEER, 24,000 Btu dual zone multi split unit. == Malfunction Indicator == Note: When several malfunctions occur at the same time, they will be displayed..."
- 19:11, 11 November 2013 diff hist +311 N Compressor Desynchronizing Malfunction (Multi ODU) Created page with "When troubleshooting this malfunction these are the main points you should look out for: * If the pressure of the system is too high; * If the electric expansion valve is work..." current
- 19:11, 11 November 2013 diff hist 0 N File:Multi-ODU-CDM-Flowchart.png current
- 19:09, 11 November 2013 diff hist +305 N Compressor Overload/Discharge Protection Malfunction (Multi ODU) Created page with "When troubleshooting this malfunction these are the main points you should look out for: * If the electric expansion valve is connected correctly or is broken; * If there is a..." current
- 19:09, 11 November 2013 diff hist 0 N File:Multi-ODU-COM-Flowchart.png current
- 19:07, 11 November 2013 diff hist +151 Communication Malfunction (Multi ODU) current
- 19:07, 11 November 2013 diff hist 0 N File:Multi-ODU-CTM2-Flowchart.png current
- 17:47, 11 November 2013 diff hist +4 Start Failure Malfunction (Multi ODU) current
- 17:47, 11 November 2013 diff hist 0 N File:Multi-ODU-SFM-Flowchart.png current
- 17:46, 11 November 2013 diff hist +66 Start Failure Malfunction (Multi ODU)
- 17:44, 11 November 2013 diff hist +340 N Communication Malfunction (Multi ODU) Created page with "When troubleshooting this malfunction these are the main points you should look out for: * If the connection wire between the indoor unit and outdoor unit is connected well. I..."
- 17:42, 11 November 2013 diff hist -70 Start Failure Malfunction (Multi ODU)
- 17:42, 11 November 2013 diff hist +361 N Start Failure Malfunction (Multi ODU) Created page with "When troubleshooting this malfunction these are the main points you should look out for: * If the connection wire of the compressor is connected properly; * If the stop durati..."
- 17:41, 11 November 2013 diff hist 0 N File:Multi-ODU-CTM-Flowchart.png current
- 17:23, 11 November 2013 diff hist +316 N Temperature Sensor Malfunction (Multi ODU) Created page with "When troubleshooting this malfunction these are the main points you should look out for: * If the temperature sensor is damaged or broken; * If the terminal of the temperature..." current
- 17:23, 11 November 2013 diff hist 0 N File:Multi-ODU-TSM-Flowchart.png current
- 17:19, 11 November 2013 diff hist +320 N Anti-High Temperature and Overload Malfunction (Multi ODU) Created page with "When troubleshooting this malfunction these are the main points you should look out for: * If the outdoor ambient temperature is within normal range; * If the outdoor fan is r..." current
- 17:18, 11 November 2013 diff hist 0 N File:Multi-ODU-AHT-Flowchart.png current
- 17:09, 11 November 2013 diff hist +267 N Capacity Charging Malfunction (Multi ODU) Created page with "When troubleshooting this malfunction these are the main points you should look out for: * Is the induction connection wire connected and working properly? * Is the main PC bo..." current
- 17:09, 11 November 2013 diff hist 0 N File:Multi-ODU-CCM-Flowchart.png current
- 17:02, 11 November 2013 diff hist +255 N PFC Protection Malfunction (Multi ODU) Created page with "When troubleshooting this malfunction these are the main points you should look out for: * Is the power supply normal? * Is the induction connection wire connected and working..." current
- 17:01, 11 November 2013 diff hist 0 N File:Multi-ODU-NO9-Flowchart.png current
- 16:56, 11 November 2013 diff hist +36 A16CM4H4R18
- 16:55, 11 November 2013 diff hist +682 A16CM4H4R18
- 16:47, 11 November 2013 diff hist +55 A16CM4H4R18
- 16:38, 11 November 2013 diff hist +43 A16CM4H4R18
- 16:32, 11 November 2013 diff hist +546 N IMP Protection Malfunction(Multi ODU) Created page with "When troubleshooting this malfunction these are the main points you should look out for: * Is the input voltage of the unit within normal range? * Is the compressor's connect..." current
- 16:29, 11 November 2013 diff hist +12 A16CM4H4R18
- 16:25, 11 November 2013 diff hist +30 A16CM4H4R18
- 16:22, 11 November 2013 diff hist 0 N File:Multi-ODU-NO7-Flowchart.png current
- 15:48, 11 November 2013 diff hist +7 A16CM4H4R18 →Malfunction Indicator
- 15:47, 11 November 2013 diff hist +4,909 N A16CM4H4R18 Created page with "A16CM4H4R18 is the 16 SEER, 18,000 Btu dual zone multi split unit. == Malfunction Indicator == Note: When several malfunctions occur at the same time, they will be displayed..."
- 15:29, 11 November 2013 diff hist +2,625 Air-Con Multi Split
- 14:54, 11 November 2013 diff hist +2,274 Air-Con Multi Split
- 13:41, 11 November 2013 diff hist +108 N Error DF (Bronze Series) Created page with "Error DF indicates a Defrost error. Once the defrost state has be fixed, it will continue normal operations." current
- 16:02, 8 November 2013 diff hist +94 Bronze Series
- 14:31, 8 November 2013 diff hist +210 Bronze Series
- 21:28, 7 November 2013 diff hist +194 N A13EM4H4G24 Created page with "A13CH4H4G24 is the 13 SEER 24,000 Btu mini split in the ''Bronze Series'' line. right|thumb|''Bronze Series'' evaporator (24k) == Remote Cont..."