ABSCI4H4S09
From Technical Support Wiki
ABSCI4H4S09 is the 22 SEER 9,000 Btu outdoor unit of Blue Series 2.
Wiring Diagram
PCB Printed Diagram
Number | Description |
---|---|
1 | Terminal of Compressor U Phase |
2 | Terminal of Compressor V Phase |
3 | Terminal of Compressor W Phase |
4 | Terminal of DC Fan |
5 | Terminal of Electronic Expansion Valve |
6 | Terminal of Compressor Overload Protection |
7 | Compressor Discharge Temperature Sensor |
8 | Terminal of AC Fan |
9 | Outdoor Pipe Temperature Sensor |
10 | Outdoor Ambient Temperature Sensor |
11 | Terminal of 4-Way Valve |
12 | Terminal of Heater |
13 | Communication Wire to Terminal Block |
14 | Terminal of Neutral Wire to Terminal Block |
15 | Terminal of Live Wire to Terminal Block |
16 | Terminal of Ground Wire |
17 | Terminal of Reactor |
Terminal of Reactor |
Exploded View and Parts List
Number | Part Name |
---|---|
1 | Front Grill |
2 | Cabinet |
3 | Axial Flow Fan Sub-Assy |
4 | Fan Motor |
5 | Left Side Plate |
6 | Motor Support |
7 | Clapboard |
8 | Compressor and Fittings |
9 | Compressor Overload Protector (External) |
10 | Electric Heater (Compressor) |
11 | 4-Way Valve Assy |
12 | Top Cover Sub-Assy |
13 | Right Side Plate Sub-Assy |
14 | Condenser Assy |
15 | Handle |
16 | Valve Support |
17 | Drainage Joint |
18 | Cut Off Valve Assy |
19 | Chassis Sub-Assy |
20 | Capacitor CBB61 |
21 | Temperature Sensor |
22 | Main Board |
23 | Electric Box Sub-Assy |
24 | Electric Box Assy |
Piping Sizes
Liquid Side | Gas Side |
---|---|
1/4" | 3/8" |