ACZCH4H4R18
From Technical Support Wiki
Revision as of 17:35, 29 April 2014 by ACINT (talk | contribs) (Created page with "ACZCI4H4R12 is the 15 SEER 12,000 Btu outdoor unit of the ''Blue Series''. right|thumb|''Blue Series'' condenser (18k) == Wiring Diagram == File...")
ACZCI4H4R12 is the 15 SEER 12,000 Btu outdoor unit of the Blue Series.
Wiring Diagram
PCB Printed Diagram
Number | Description |
---|---|
1 | Compressor wiring connection terminal |
2 | ODU heat exchanger middle copper pipe temp sensor terminal |
3 | Compressor overload protection terminal |
4 | ODU temp sensor terminal |
5 | EXV terminal |
6 | Outdoor fan terminal |
7 | Four-way valve terminal |
8 | Chasis electric heating wiring terminal |
9 | Communication cable with IDU |
10 | Power supply live wire |
11 | Ground wire |
12 | Power supply neutral wire |
13 | PFC inductance wire |
Exploded View and Parts List
Number | Part Name |
---|---|
1 | Front Grill |
2 | Cabinet |
3 | Axial Flow Fan Sub-Assy |
4 | Fan Motor |
5 | Left Side Plate |
6 | Motor Support |
7 | Clapboard |
8 | Compressor and Fittings |
9 | Compressor Overload Protector (External) |
10 | Electric Heater (Compressor) |
11 | 4-Way Valve Assy |
12 | Top Cover Sub-Assy |
13 | Right Side Plate Sub-Assy |
14 | Condenser Assy |
15 | Handle |
16 | Valve Support |
17 | Drainage Joint |
18 | Cut Off Valve Assy |
19 | Chassis Sub-Assy |
20 | Capacitor CBB61 |
21 | Temperature Sensor |
22 | Main Board |
23 | Electric Box Sub-Assy |
24 | Electric Box Assy |
Piping Sizes
Liquid Side | Gas Side |
---|---|
1/4" | 3/8" |