ACZEM4H4R18
From Technical Support Wiki
ACZEM4H4R18 is the 15 SEER 18,000 Btu indoor unit of the Blue Series.
Remote Control
# | Name | Description |
1 | ON/OFF | Press to start or stop operation. |
2 | MODE | Press to select operation mode (Auto/Cool/Dry/Fan/Heat). |
3 | + (Raise) | Press to raise the temperature setting. |
3 | - (Lower) | Press to lower the temperature setting. |
4 | FAN | Press to set fan speed. Rotates between Auto and Speeds 1-4. |
5 | SWING | Press to set swing angle. |
6 | SLEEP | Press to turn on sleep function. |
7 | TIMER | Manage the on and off timer with this button. |
Wiring Diagram
PCB Printed Diagram
Number | Description |
---|---|
1 | Live wire interface |
2 | Neutral wire interface |
3 | Fuse |
4 | PG motor |
5 | Auto button |
6 | Up and down swing terminal interface |
7 | PG feedback |
8 | IDU and ODU communication interface |
9 | Display terminal interface |
10 | Jumper |
11 | Ambient temperature sensor |
12 | Tube temperature sensor |
Exploded View and Parts List
Number | Part Name |
---|---|
1 | Front Panel Sub-Assy |
2 | Filter Sub-Assy |
3 | Screw Cover |
4 | Front Case Sub-Assy |
5 | Guide Louver |
6 | Air Louver 1 |
7 | Helicoid Tongue |
8 | Left Axile Bush |
9 | Rear Case Assy |
10 | Rubber Plug (Water Tray) |
11 | O-Gasket of Cross Fan Bearing |
12 | O-Gasket Sub-Assy of Bearing |
13 | Evaporator Support |
14 | Evaporator Assy |
15 | Wall Mounting Frame |
16 | Cross Flow Fan |
17 | Motor Press Plate |
18 | Fan Motor |
19 | Pipe Clamp |
20 | Drainage Hose |
21 | Step Motor |
22 | Crank |
23 | Display Board |
24 | Air Louver 2 |
25 | Electric Box Assy |
26 | Lower Shield of Electric Box |
27 | Electric Box |
28 | Axile Bush |
29 | Terminal Board |
30 | Jumper |
31 | Electric Box Cover 2 |
32 | Main Board |
33 | Shield Cover of Electric Box |
34 | Electric Box Cover 1 |
35 | Remote Controller |
36 | Temperature Sensor |
37 | Temperature Sensor |