TD Prime Heat Pump Specs
From Technical Support Wiki
Specification Table of the Heat Pump TD Prime ducted units.
| Outdoor Model | ATDCI4H4G24 | ATDCI4H4G36 | ATDCI4H4G48 | ATDCI4H4G60 | |||
|---|---|---|---|---|---|---|---|
| Outdoor Power Supply | V/Ph/Hz | 208-203V/1Ph/60Hz | 208-203V/1Ph/60Hz | 208-203V/1Ph/60Hz | 208-203V/1Ph/60Hz | ||
| Cooling | Capacity | Btu/h | 24000 | 34500 | 47000 | 56000 | |
| W | 7033 | 10110 | 13774 | 16411 | |||
| EER | Btu/Wh | 11.6 | 11.6 | 11.6 | 10.8 | ||
| SEER | Btu/Wh | 17.5 | 17.5 | 17.5 | 17.5 | ||
| Heating | Capacity | Btu/h | 24000 | 34000 | 46500 | 55000 | |
| W | 7033 | 10110 | 13627 | 16118 | |||
| COP | Btu/Wh | 13.0 | 11.9 | 12.9 | 11.5 | ||
| HSPF | Btu/Wh | 9.5 | 9.0 | 9.5 | 9.5 | ||
| Min. Circuit Ampacity (IU/OU) | A | 3.5/17.7 | 5.1/24.2 | 7.5/31.9 | 7.5/36.5 | ||
| Compressor | Type | GMCC Twin-rotary DC | Mitsubishi Twin-rotary DC | ||||
| Outdoor Dimension | Unit (WxHxD) | inch | 29x25x29 | 29x25x29 | 29x33x29 | 29x33x29 | |
| Packaging (WxHxD) | inch | 30x26x30 | 30x26x30 | 30x35x30 | 30x35x30 | ||
| Indoor Model | ATDEM4H4G24 | ATDEM4H4G36 | ATDEM4H4G48 | ATDEM4H4G60 | |||
| Cooling | Capacity | Btu/h | 24000 | 34500 | 47000 | 56000 | |
| SEER | 17.5 | 17.5 | 17.5 | 17.5 | |||
| Heating | Capacity | Btu/h | 24000 | 34000 | 46500 | 55000 | |
| HSPF | 9.5 | 9.0 | 9.5 | 9.5 | |||
| Indoor Max Current | A | 0.91 | 1.35 | 2.39 | 2.43 | ||
| Indoor Air Flow | CFM | 780 | 1300 | 1500 | 1750 | ||
| ESP | Pa | 25 | 37 | 50 | 50 | ||
| Indoor Dimension | Unit (WxHxD) | inch | 20x46x22 | 20x46x22 | 22x53x24 | 22x53x24 | |
| Packaging (WxHxD) | inch | 23x48x26 | 23x48x26 | 26x55x28 | 26x55x28 | ||