MHI VRF FDU

From Technical Support Wiki
Revision as of 14:50, 31 October 2018 by ACINT (talk | contribs)
Jump to: navigation, search

This is the support page for the Duct Connected High Static Pressure indoor unit (FDU) for MHI VRF air conditioners.

Mitsubishi Heavy Industries VRF
Duct Connected High Static Pressure (FDU)
Blue2-Logo.png
Voltage 220V
Capacities (kW) 4.5-16.0
Heat Pump? Yes

Model Numbers

  • FDU45KXE6F
  • FDU56KXE6F
  • FDU71KXE6F
  • FDU90KXE6F
  • FDU112KXE6F
  • FDU140KXE6F
  • FDU160KXE6F
  • FDU224KXE6F
  • FDU280KXE6F

Specifications

Item Unit FDU45KXE6F FDU56KXE6F FDU71KXE6F FDU90KXE6F FDU112KXE6F FDU140KXE6F FDU160KXE6F
Nominal Cooling Capacity kW 4.5 5.6 7.1 9.0 11.2 14.0 16.0
Nominal Heating Capacity kW 5.0 6.3 8.0 10.0 12.5 16.0 18.0
Power Source 1 Phase 220V, 60Hz
Power Consumption Cooling kW 0.10 0.24 0.31 0.35 0.42
Heating 0.10 0.24 0.31 0.35 0.42
Sound Power Level dB(A) 60 65 ---
Sound Pressure Level dB(A) Hi: 32 Me: 29 Lo: 26 Hi: 33 Me: 29 Lo: 25 Hi: 38 Me: 36 Lo: 30 Hi: 40 Me: 34 Lo: 29 Hi: 40 Me: 35 Lo: 30
Exterior Dimensions H x W x D mm 280x750x635 280x950x635 280x1370x740
Net Weight kg 29 34 54
Air Flow (Standard) m3/min Hi: 10 Me: 9 Lo: 8 Hi: 19 Me: 15 Lo: 10 Hi: 28 Me: 25 Lo: 19 Hi: 32 Me: 26 Lo: 20 Hi: 35 Me: 28 Lo: 22
Maximum External Static Pressure Pa 200
Outside Air Intake Possible
Air Filter Procure Locally
Remote Control (option) wired: RC-EX3, RC-E5, RCH-E3 wireless: RCN-KIT4-E2
Refrigerant Piping Size mm (in) Liquid Line: ⌀6.35 (1/4") Gas Line: ⌀12.7 (1/2") Liquid Line: ⌀9.52 (3/8") Gas Line: ⌀15.88 (5/8")
Item Unit FDU224KXE6F FDU280KXE6F
Nominal Cooling Capacity kW 22.4 28.0
Nominal Heating Capacity kW 25.0 31.5
Power Source 1 Phase 220V, 60Hz
Power Consumption Cooling kW 1.16 1.16
Heating 1.16 1.16
Sound Power Level dB(A) ----
Sound Power Level dB(A) Hi: 50 Me: 47 Lo: 45
Exterior Dimensions H x W x D mm 379x1600x893
Net Weight kg 89
Air Flow m3/min Hi: 72 Me: 64 Lo: 56
Maximum External Static Pressure Pa 200
Outside Air Intake Possible (on Return Duct)
Air Filter Procure locally
Remote Control (option) wired: RC-EX3, RC-E5, RCH-E3 wireless: RCN-KIT4-E2