ACZEM4H4R24

From Technical Support Wiki
Revision as of 18:07, 29 April 2014 by ACINT (talk | contribs)
Jump to: navigation, search

ACZEM4H4R24 is the 15 SEER 24,000 Btu indoor unit of the Blue Series.

Blue Series evaporator (24k)

Remote Control

Remote Control
# Name Description
1 ON/OFF Press to start or stop operation.
2 MODE Press to select operation mode (Auto/Cool/Dry/Fan/Heat).
3 + (Raise) Press to raise the temperature setting.
3 - (Lower) Press to lower the temperature setting.
4 FAN Press to set fan speed. Rotates between Auto and Speeds 1-4.
5 SWING Press to set swing angle.
6 SLEEP Press to turn on sleep function.
7 TIMER Manage the on and off timer with this button.

Wiring Diagram

ACZEM4H4R24 Wiring Diagram

PCB Printed Diagram

ACZEM4H4R24 PCB Printed Diagram
Number Description
1 DC fan interface
2 Auto button
3 Up and down swing terminal interface
4 Display terminal interface
5 Jumper cap
6 Ambient temperature sensor
7 Tube temperature sensor
8 IDU and ODU communication interface
9 Live wire interface
10 Fuse
11 Neutral wire interface
12 Earth wire terminal interface










Exploded View and Parts List

ACZEM4H4R24 Exploded View
Number Part Name
1 Front Panel Sub-Assy
2 Filter Sub-Assy
3 Screw Cover
4 Front Case-Assy
5 Air Louver
6 Helicoid Tongue
7 Left Axile Bush
8 Rear Case Assy
9 Rubber Plug (Water Tray)
10 Ring of Bearing
11 O-Gasket Sub-Assy of Bearing
12 Cross Flow Fan
13 Evaporator Support
14 Evaporator Assy
15 Wall Mounting Frame
16 Motor Press Plate
17 Fan Motor
18 Connecting Pipe Clamp
19 Drainage Hose
20 Step Motor
21 Crank
22 Display Board
23 Mesh Enclosure (Air Outlet)
24 Guide Louver
25 Axile Bush
26 Electric Box
27 Terminal Board
28 Electric Box Cover 2
29 Front Case
30 Main Board
31 Shield Cover of Electric Box
32 Electric Box Cover 1
33 Jumper
34 Electric Box-Assy
35 Ambient Temperature Sensor
36 Temperature Sensor
37 Remote Controller