ABXCI4H4S12

From Technical Support Wiki
Revision as of 13:06, 15 July 2019 by ACINT (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

ABXCI4H4S12 is the 21 SEER 12,000 Btu outdoor unit of Blue Series 3.

Blue Series 3 condenser (12k)

Wiring Diagram

ABXCI4H4S12 Wiring Diagram

PCB Printed Diagram

ABSXI4H4S12 PCB Diagram
Number Description
1 Terminal of Compressor U/V/W Phase
2 Terminal of Reactor (optional)
3 Terminal of Neutral Wire, connect to the terminal panel 1(N)
4 Terminal of Live Wire, connect to the terminal panel 2(L)
5 Terminal of Signal Wire, connect to the terminal panel 3(SI)
6 Terminal of AC Fan
7 Cool Valve Terminal
8 Heater Terminal
9 4-way Valve Terminal
10 Terminal of DC Fan
11 Terminal of Electronic Expansion Valve
12 Outdoor Ambient Temperature Sensor
13 Outdoor Pipe Temperature Sensor
14 Compressor Discharge Temperature Sensor
15 Terminal of Compressor Overload Protector
16 Over Pressure Sensor
17 DRED Function




Exploded View and Parts List

ABXCI4H4S12 Exploded View
Number Part Name
1 Panel Parts
2 Propeller Fan Blade
3 Fan Motor
4 Motor Supporter Assy
5 Mounting Plate
6 Upper Board
7 Back Guard
8 Condenser Assembly
9 Base Holder Part
10 Clapboard
11 PFC Inductance
12 4-Way Valve Assembly
13 4-Way Valve Coil
14 4-Way Valve
15 Compressor
16 Compressor Connect Wire
17 Capillary Assembly
18 1/4" 2-Way Valve
19 3/8" 3-Way Valve
20 Right Side Board
21 Wiring Distribution Cover Assy
22 Fixed Board
23 Connecting Board
24 Wire Terminal Board
25 Electric Box
26 Outdoor Main Control Board Component
27 Electric Box Cover
28 Temperature Sensor
29 Temperature Sensor
30 Temperature Sensor
31 Sensor Mounting Plate


Piping Sizes

Liquid Side Gas Side
1/4" 3/8"

Accessories