Difference between revisions of "Platinum Series Troubleshooting (9K & 12K)"

From Technical Support Wiki
Jump to: navigation, search
Line 18: Line 18:
 
| Green Indicator
 
| Green Indicator
 
|-  
 
|-  
 +
|1
 +
| High pressure protection of system
 +
| E1
 +
| Off 3s and blink once
 +
|
 +
|
 +
|
 +
|
 +
|
 +
| During cooling and drying operation, all loads except the indoor fan stop operation. During heating operation, the entire unit stops.
 +
|
 +
* Refrigerant was superabundant;
 +
* Poor heat exchange (including filth blockage of heat exchanger and bad radiating environment);
 +
* Ambient temperature is too high.
 +
|-
 +
| 2
 +
|
 
|}
 
|}

Revision as of 15:13, 13 November 2013

NO. Malfunction Name Display Method of Indoor Unit Display Method of Outdoor Unit A/C Status Possible Causes
Dual-8 Code Display Indicator Display Indicator Display
Operation Indicator Cooling Indicator Heating Indicator Yellow Indicator Red Indicator Green Indicator
1 High pressure protection of system E1 Off 3s and blink once During cooling and drying operation, all loads except the indoor fan stop operation. During heating operation, the entire unit stops.
  • Refrigerant was superabundant;
  • Poor heat exchange (including filth blockage of heat exchanger and bad radiating environment);
  • Ambient temperature is too high.
2