Difference between revisions of "SD Premium Specifications"
From Technical Support Wiki
| Line 29: | Line 29: | ||
| 1 | | 1 | ||
| 1 | | 1 | ||
| + | |- | ||
| + | !scope="row" colspan="2" | Cooling Capacity (Min~Max) | ||
| + | | Btu/h | ||
| + | | 24000(6700-26000) | ||
| + | | 36000(11800-368000) | ||
| + | | 56000(13000-57000) | ||
| + | |- | ||
| + | !scope="row" colspan="2" | Heating Capacity (Min~Max) | ||
| + | | Btu/h | ||
| + | | 24000(6700-26000) | ||
| + | | 36000(8900-38200) | ||
| + | | 56000(13000-57000) | ||
| + | |- | ||
| + | !scope="row" colspan="2" | Cooling Power Input | ||
| + | | W | ||
| + | | 2200 | ||
| + | | 3730 | ||
| + | | 6570 | ||
| + | |- | ||
| + | !scope="row" colspan="2" | Heating Power Input | ||
| + | | W | ||
| + | | 2000 | ||
| + | | 3200 | ||
| + | | 5470 | ||
| + | |- | ||
| + | !scope="row" colspan="2" | Cooling Current Input | ||
| + | | A | ||
| + | | 9.6 | ||
| + | | 16.5 | ||
| + | | 29.5 | ||
| + | |- | ||
| + | !scope="row" colspan="2" | Heating Current Input | ||
| + | | A | ||
| + | | 8.7 | ||
| + | | 14.1 | ||
| + | | 23 | ||
| + | |- | ||
| + | !scope="row" colspan="2" | Min. Circuit Ampacity | ||
| + | | A | ||
| + | | 15 | ||
| + | | 23 | ||
| + | | 25 | ||
| + | |- | ||
| + | !scope="row" colspan="2" | Max Fuse/Breaker | ||
| + | | A | ||
| + | | 25 | ||
| + | | 35 | ||
| + | | 50 | ||
| + | |- | ||
| + | !scope="row" colspan="2" | Power Cable | ||
| + | | No.xAWG | ||
| + | | OU 3X12/IU 3X16 | ||
| + | | OU 3X10/IU 3X16 | ||
| + | | OU 3X10/IU 3X14 | ||
| + | |- | ||
| + | !scope="row" colspan="2" | Communication Cable | ||
| + | | No.xAWG | ||
| + | | 4X16 | ||
| + | | 4X16 | ||
| + | | 4X16 | ||
| + | |- | ||
| + | !scope="row" colspan="2" | EER | ||
| + | | Btu/Wh | ||
| + | | 10.9 | ||
| + | | 9.55 | ||
| + | | 8.55 | ||
| + | |- | ||
| + | !scope="row" colspan="2" | COP | ||
| + | | Btu/Wh | ||
| + | | 11.95 | ||
| + | | 11.26 | ||
| + | | 10.24 | ||
| + | |- | ||
| + | !scope="row" colspan="2" | SEER | ||
| + | | Btu/Wh | ||
| + | | 18 | ||
| + | | 18 | ||
| + | | 17.5 | ||
| + | |- | ||
| + | !scope="row" colspan="2" | HSPF | ||
| + | | Btu/Wh | ||
| + | | 10 | ||
| + | | 11 | ||
| + | | 9.5 | ||
| + | |- | ||
| + | !scope="row" colspan="2" rowspan="2" | Moisture Removal | ||
| + | | L/h | ||
| + | | 2.2 | ||
| + | | 4.5 | ||
| + | | 7 | ||
| + | |- | ||
| + | | Pts/h | ||
| + | | 4.64 | ||
| + | | 9.5 | ||
| + | | 14.8 | ||
| + | |- | ||
| + | !scope="row" colspan="2" rowspan="2" | Cooling Operating Range | ||
| + | | °F | ||
| + | | 5~118 | ||
| + | | 5~118 | ||
| + | | 5~118 | ||
| + | |- | ||
| + | | °C | ||
| + | | -15~48 | ||
| + | | -15~48 | ||
| + | | -15~48 | ||
| + | |- | ||
| + | !scope="row" colspan="2" rowspan="2" | Heating Operating Range | ||
| + | | °F | ||
| + | | -13~75 | ||
| + | | -13~75 | ||
| + | | -13~75 | ||
| + | |- | ||
| + | | °C | ||
| + | | -25~24 | ||
| + | | -25~24 | ||
| + | | -25~24 | ||
| + | |- | ||
| + | !scope="row" colspan="1" rowspan="13" | Indoor Unit | ||
| + | !scope="row" colspan="1" rowspan="2" | Air Flow | ||
| + | | CFM | ||
| + | | 852 | ||
| + | | 941 | ||
| + | | 1647 | ||
| + | |- | ||
| + | | m<sup>3/h | ||
| + | | 1450 | ||
| + | | 1600 | ||
| + | | 2800 | ||
| + | |- | ||
|} | |} | ||
Revision as of 15:34, 20 November 2020
| Parameter | Unit | Value | |||
|---|---|---|---|---|---|
| Model | ASDCI4H4S24/ASDEM4H4S24 | ASDEM4H4S36/ASDEM4H4S36 | ASDEM4H4S60/ASDEM4H4S60 | ||
| Power Supply | Rated Voltage | V | 208/230 | 208/230 | 208/230 |
| Rated Frequency | Hz | 60 | 60 | 60 | |
| Phases | 1 | 1 | 1 | ||
| Cooling Capacity (Min~Max) | Btu/h | 24000(6700-26000) | 36000(11800-368000) | 56000(13000-57000) | |
| Heating Capacity (Min~Max) | Btu/h | 24000(6700-26000) | 36000(8900-38200) | 56000(13000-57000) | |
| Cooling Power Input | W | 2200 | 3730 | 6570 | |
| Heating Power Input | W | 2000 | 3200 | 5470 | |
| Cooling Current Input | A | 9.6 | 16.5 | 29.5 | |
| Heating Current Input | A | 8.7 | 14.1 | 23 | |
| Min. Circuit Ampacity | A | 15 | 23 | 25 | |
| Max Fuse/Breaker | A | 25 | 35 | 50 | |
| Power Cable | No.xAWG | OU 3X12/IU 3X16 | OU 3X10/IU 3X16 | OU 3X10/IU 3X14 | |
| Communication Cable | No.xAWG | 4X16 | 4X16 | 4X16 | |
| EER | Btu/Wh | 10.9 | 9.55 | 8.55 | |
| COP | Btu/Wh | 11.95 | 11.26 | 10.24 | |
| SEER | Btu/Wh | 18 | 18 | 17.5 | |
| HSPF | Btu/Wh | 10 | 11 | 9.5 | |
| Moisture Removal | L/h | 2.2 | 4.5 | 7 | |
| Pts/h | 4.64 | 9.5 | 14.8 | ||
| Cooling Operating Range | °F | 5~118 | 5~118 | 5~118 | |
| °C | -15~48 | -15~48 | -15~48 | ||
| Heating Operating Range | °F | -13~75 | -13~75 | -13~75 | |
| °C | -25~24 | -25~24 | -25~24 | ||
| Indoor Unit | Air Flow | CFM | 852 | 941 | 1647 |
| m3/h | 1450 | 1600 | 2800 | ||