Difference between revisions of "ABXEM4H4S24"

From Technical Support Wiki
Jump to: navigation, search
 
Line 1: Line 1:
ABXEM4H4S09 is the 21 SEER 24,000 Btu indoor unit of ''[[Blue Series 3]]''. [[File:BS3-IDU.png|right|thumb|''Blue Series 3'' evaporator (24k)]]
+
ABXEM4H4S24 is the 21 SEER 24,000 Btu indoor unit of ''[[Blue Series 3]]''. [[File:BS3-IDU.png|right|thumb|''Blue Series 3'' evaporator (24k)]]
 
== Remote Control ==
 
== Remote Control ==
 
[[File:Blue-series-2-remote.png|left|thumb|200px|Remote Control]]
 
[[File:Blue-series-2-remote.png|left|thumb|200px|Remote Control]]

Latest revision as of 14:44, 27 September 2019

ABXEM4H4S24 is the 21 SEER 24,000 Btu indoor unit of Blue Series 3.

Blue Series 3 evaporator (24k)

Remote Control

Remote Control
# Name Description
1 ON/OFF Press to start or stop operation.
2 MODE Press to select operation mode (Auto/Cool/Dry/Fan/Heat).
3 FAN Used to select the fan speed in sequence: auto, high, medium, or low.
4 ROOM TEMPERATURE SETTING Press to raise the temperature setting. Can also be used to adjust the timer and adjust the current time.
5 ROOM TEMPERATURE SETTING Press to lower the temperature setting. Can also be used to adjust the timer and adjust the current time.
6 SMART Adjust smart settings.
7 SWING Used to stop or start vertical adjustment louver swinging and set the desired up/down airflow direction.
8 SLEEP Used to set or cancel Sleep Mode operation.
9 IFEEL Used to set IFEEL operation.
10 CLOCK Used to set the current time.
11 TIMER ON Used to turn the timer function on.
12 TIMER OFF Used to turn the timer function off.
13 SUPER Used to start/stop the super cool/heat function. (Super cooling operates at high fan speed with a default 64 F temperature setting. Super heating operates at high fan speed with a default 89 F temperature setting.)
14 DIMMER Pressing this button will dim the display on the indoor unit. Pressing any button will reverse the dimmer.

Wiring Diagram

ABXEM4H4S24 Wiring Diagram

PCB Printed Diagram

ABXEM4H4S24 PCB Printed Diagram
Number Description
1 Interface of DC Motor (White)
2 Wiring Control Interface (White)
3 Room Temperature Sensor (Yellow)
4 Pipe Temperature Sensor (Black)
5 Humidity Detection Interface (White)
6 Panel Board Switch Interface (White)
7 Up & Down Swing (Red)
8 Left & Right Swing (White)
9 Switch Button
10 IFD Interface
11 Display Interface
12 Out Input Interface (Red)
13 WiFi Interface
14 Protective Tube



Exploded View and Parts List

ABXEM4H4S24 Exploded View
Number Part Name
1 Installation Plate Assy
2 Base Holder Part
3 Step Motor
4 Center Staff
5 Motor Guard
6 Vertical Level Vane
7 Center Staff
8 Vertical Level Vane
9 Vertical Level Vane
10 Level Vane
11 Axis Sheath
12 Cross-Flow Fan Blade
13 Bearing
14 Baffle
15 Refrigeration System
16 Shell
17 Display Component
18 Panel
19 Ornamental Part
20 Temperature Sensor
21 Temperature Sensor
22 Fan Motor
23 Motor Cover
24 Motor Guard
25 Baffle
26 Baffle
27 Water Pipe Parts
28 Step Motor
29 Elec Joint Box Plate
30 Electric Box
31 Indoor Main Control Board Component
32 Electric Box Cover
33 Electric Box Cover
34 Wire Terminal Board
35 Over Clamp
36 Wiring Distribution Cover Assy
37 Remote Controller
38 Filter Net