Difference between revisions of "Air-Con Multi Split"
From Technical Support Wiki
Line 157: | Line 157: | ||
== Error Codes == | == Error Codes == | ||
{| class="wikitable" | {| class="wikitable" | ||
− | + | | Error Code | |
− | + | | Error Description | |
|- | |- | ||
|U8 | |U8 |
Revision as of 18:23, 28 June 2017
As we transition to the more efficient 22-21 SEER Multi Splits, please pardon our dust as we rebuild this wiki page to reflect our new units. All information on the 16 SEER units are now under the Legacy Support menu. Thank you.
This is the support page for the 22-21 SEER Air-Con Multi Split line. If you're looking for our 16 SEER models please visit the Air-Con Multi Split 16 SEER page.
Indoor Units (Wall Mount Type)
Indoor Units (Cassette Type)
Indoor Units (Ducted Type)
Indoor Units (Floor & Ceiling Type)
Outdoor Units
Possible Combinations
These are the recommended indoor-outdoor unit combinations.
Zones | Outdoor Unit | Indoor Units | Indoor Units | Indoor Units | Indoor Units | Indoor Units | Indoor Units | Indoor Units | Indoor Units |
Dual Zone | A16CM4H4R18 | A16EM4H4R09 | A16EM4H4R09 | A16EM4H4R18 | |||||
A16EM4H4R09 | A16EM4H4R12 | ||||||||
Tri Zone | A16CM4H4R24 | A16EM4H4R09 | A16EM4H4R09 | A16EM4H4R12 | A16EM4H4R09 | A16EM4H4R18 | |||
A16EM4H4R09 | A16EM4H4R09 | A16EM4H4R12 | A16EM4H4R12 | ||||||
A16EM4H4R09 | |||||||||
Quad Zone |
|
A16EM4H4R09 | A16EM4H4R12 | A16EM4H4R12 | A16EM4H4R09 | A16EM4H4R18 | |||
A16EM4H4R09 | A16EM4H4R12 | A16EM4H4R12 | A16EM4H4R09 | A16EM4H4R18 | |||||
A16EM4H4R09 | A16EM4H4R12 | A16EM4H4R09 | A16EM4H4R18 | ||||||
A16EM4H4R09 | |||||||||
Quint Zone | A16CM4H4R42 | A16EM4H4R09 | A16EM4H4R12 | A16EM4H4R09 | A16EM4H4R09 | A16EM4H4R09 | A16EM4H4R12 | A16EM4H4R18 | A16EM4H4R09 |
A16EM4H4R09 | A16EM4H4R12 | A16EM4H4R09 | A16EM4H4R09 | A16EM4H4R09 | A16EM4H4R12 | A16EM4H4R18 | A16EM4H4R12 | ||
A16EM4H4R09 | A16EM4H4R12 | A16EM4H4R12 | A16EM4H4R12 | A16EM4H4R09 | A16EM4H4R12 | A16EM4H4R12 | A16EM4H4R18 | ||
A16EM4H4R09 | A16EM4H4R12 | A16EM4H4R18 | A16EM4H4R12 | A16EM4H4R12 | A16EM4H4R09 | ||||
A16EM4H4R09 |
- Note: Each indoor unit combination is viewed as a column.
- Note: Both quad zone outdoor units are capable of the same combinations but make your judgement on the correct one to use based on room size.
- Note: There are more possible combinations than those listed above. Please use proper capacity judgment when making multi-split combinations.
Error Codes
Error Code | Error Description |
U8 | Zero Cross Detection Circuit Malfunction (Indoor Unit) |
Document Downloads
- Outdoor Unit User Manual
- Indoor Unit User Manual
- Outdoor Unit Service Manual
- Indoor Unit Service Manual
- Multi Split Submittal Sheet
Warranty Information
Each Multi Split unit set has a warranty of 1 year for parts and 5 years for the compressor. If you need more information, please visit the Air-Con Warranty Policy page.