Difference between revisions of "ASKCI4H4R18"

From Technical Support Wiki
Jump to: navigation, search
(Created page with "ASKCI4H4R18 is the 17-16 SEER 18,000 Btu outdoor unit of the ''Sky Split Series''. right|thumb|''Sky Split Series'' condenser (18k) == Wiring Diag...")
 
Line 9: Line 9:
 
|-
 
|-
 
| 1
 
| 1
| Compressor UVW three phases
+
| Live wire input
 
|-
 
|-
 
| 2  
 
| 2  
| Reactor interface 2
+
| Neutral wire input
 
|-
 
|-
 
| 3  
 
| 3  
| Reactor interface 1
+
| Control power output [1-DC bus voltage, 3-GND]
 
|-
 
|-
 
| 4  
 
| 4  
| Fan interface
+
| DC Fan Motor 2
 
|-
 
|-
 
| 5  
 
| 5  
| 4-way valve interface
+
| DC Fan Motor 1
 
|-
 
|-
 
| 6
 
| 6
| Power supply neutral wire
+
| Control power output [1-GND 2-18V, 3-15V]
 
|-
 
|-
 
| 7  
 
| 7  
| Power supply neutral wire
+
| Communication line [1-3.3V, 2-TX, 3-RX, 4-GND]
 
|-
 
|-
 
| 8  
 
| 8  
| Communication wire
+
| Communication line [1-pin GND, 2-pin B and 3-pin A]
 
|-
 
|-
 
| 9
 
| 9
| Overload input
+
| Communication line [1-pin+12V, 2-pin B, 3-pin A, 4-pin GND]
 
|-
 
|-
 
| 10  
 
| 10  
| Temperature sensor interface
+
| High pressure switch for fan speed adjustment
 +
|-
 +
| 11
 +
| High pressure switch for system protection
 +
|-
 +
| 12
 +
| Low pressure switch for system protection
 +
|-
 +
| 13
 +
| Compressor overload protection
 +
|-
 +
| 14
 +
| Temperature Sensor
 +
|-
 +
| 15
 +
| Electronic expansion valve line
 +
|-
 +
| 16
 +
| Compressor electrical heater
 +
|-
 +
| 17
 +
| Chassis electrical heater
 +
|-
 +
| 18
 +
| 4-way valve
 
|}
 
|}
 
<br />
 
<br />

Revision as of 12:46, 16 June 2015

ASKCI4H4R18 is the 17-16 SEER 18,000 Btu outdoor unit of the Sky Split Series.

Sky Split Series condenser (18k)

Wiring Diagram

ASKCI4H4R18 Wiring Diagram

PCB Printed Diagram

ASKCI4H4R18 Main Board Diagram
Number Description
1 Live wire input
2 Neutral wire input
3 Control power output [1-DC bus voltage, 3-GND]
4 DC Fan Motor 2
5 DC Fan Motor 1
6 Control power output [1-GND 2-18V, 3-15V]
7 Communication line [1-3.3V, 2-TX, 3-RX, 4-GND]
8 Communication line [1-pin GND, 2-pin B and 3-pin A]
9 Communication line [1-pin+12V, 2-pin B, 3-pin A, 4-pin GND]
10 High pressure switch for fan speed adjustment
11 High pressure switch for system protection
12 Low pressure switch for system protection
13 Compressor overload protection
14 Temperature Sensor
15 Electronic expansion valve line
16 Compressor electrical heater
17 Chassis electrical heater
18 4-way valve













Exploded View and Parts List

ACZCI4H4R09 Exploded View
Number Part Name
1 Front Grill
2 Cabinet
3 Axial Flow Fan Sub-Assy
4 Fan Motor
5 Left Side Plate
6 Motor Support
7 Clapboard
8 Compressor and Fittings
9 Compressor Overload Protector (External)
10 Electric Heater (Compressor)
11 4-Way Valve Assy
12 Top Cover Sub-Assy
13 Right Side Plate Sub-Assy
14 Condenser Assy
15 Handle
16 Valve Support
17 Drainage Joint
18 Cut Off Valve Assy
19 Chassis Sub-Assy
20 Capacitor CBB61
21 Temperature Sensor
22 Main Board
23 Electric Box Sub-Assy
24 Electric Box Assy

Piping Sizes

Liquid Side Gas Side
1/4" 3/8"

Accessories