Difference between revisions of "A16CM4H4R42"
From Technical Support Wiki
(Created page with "A16CM4H4R42 is the 16 SEER, 42,000 Btu quint zone multi split unit. thumb|right|Multi Split Condenser == Wiring Diagram== File:Multi-42K-ODU-WD.jpg|...") |
|||
| Line 16: | Line 16: | ||
|- | |- | ||
| 3 | | 3 | ||
| − | | | + | | Front Side Plat Sub-Assy |
|- | |- | ||
| 4 | | 4 | ||
| − | | | + | | Sensor Sub-Assy |
|- | |- | ||
| 5 | | 5 | ||
| − | | | + | | Chassis Sub-Assy |
|- | |- | ||
| 6 | | 6 | ||
| − | | | + | | Insulated Board (Cover of Electric Box) |
|- | |- | ||
| 7 | | 7 | ||
| − | | | + | | Pressure Protect Switch |
|- | |- | ||
| 8 | | 8 | ||
| − | | | + | | Compressor Mounting Plate Sub-Assy |
|- | |- | ||
| 9 | | 9 | ||
| − | | Compressor | + | | Compressor and Fittings |
|- | |- | ||
| 10 | | 10 | ||
| − | | | + | | Connection Pipe |
|- | |- | ||
| 11 | | 11 | ||
| − | | | + | | Gas-Liquid Separator Sub-Assy |
|- | |- | ||
| 12 | | 12 | ||
| − | | | + | | Bidirection Accumulator |
|- | |- | ||
| 13 | | 13 | ||
| − | | | + | | Connecting Pipe of "U" Shape |
|- | |- | ||
| 14 | | 14 | ||
| − | | | + | | Right Side Plate Sub-Assy |
|- | |- | ||
| 15 | | 15 | ||
| − | | | + | | Strainer A |
|- | |- | ||
| 16 | | 16 | ||
| − | | | + | | Cut-Off Valve |
|- | |- | ||
| 17 | | 17 | ||
| Line 61: | Line 61: | ||
|- | |- | ||
| 18 | | 18 | ||
| − | | | + | | Strainer A |
|- | |- | ||
| 19 | | 19 | ||
| − | | | + | | Valve Support Assy |
|- | |- | ||
| 20 | | 20 | ||
| − | | | + | | Oil Separator |
|- | |- | ||
| 21 | | 21 | ||
| − | | | + | | Tube Clip |
|- | |- | ||
| 22 | | 22 | ||
| − | | | + | | Strainer A |
|- | |- | ||
| 23 | | 23 | ||
| − | | | + | | 4-Way Valve |
|- | |- | ||
| 24 | | 24 | ||
| − | | | + | | Handle |
|- | |- | ||
| 25 | | 25 | ||
| − | | | + | | 4-Way Valve Assy |
|- | |- | ||
| 26 | | 26 | ||
| − | | | + | | Pressure Protect Switch |
|- | |- | ||
| 27 | | 27 | ||
| − | | | + | | Discharge Tube Sub-Assy |
|- | |- | ||
| 28 | | 28 | ||
| − | | | + | | inhalation Tub Sub-Assy |
|- | |- | ||
| 29 | | 29 | ||
| − | | | + | | Capillary Sub-Assy (Oil Separator) |
|- | |- | ||
| 30 | | 30 | ||
| − | | | + | | Condenser Assy |
|- | |- | ||
| 31 | | 31 | ||
| − | | | + | | Rear Grill |
|- | |- | ||
| 32 | | 32 | ||
| Line 109: | Line 109: | ||
|- | |- | ||
| 34 | | 34 | ||
| − | | | + | | Reactor Sub-Assy |
|- | |- | ||
| 35 | | 35 | ||
| − | | | + | | Cover of Reactor Box |
|- | |- | ||
| 36 | | 36 | ||
| − | | | + | | PFC Inductance |
|- | |- | ||
| 37 | | 37 | ||
| − | | | + | | Reactor Box |
| + | |- | ||
| + | | 38 | ||
| + | | Capacitor | ||
| + | |- | ||
| + | | 39 | ||
| + | | Electric Box | ||
| + | |- | ||
| + | | 40 | ||
| + | | Main Board | ||
| + | |- | ||
| + | | 41 | ||
| + | | Radiator | ||
| + | |- | ||
| + | | 42 | ||
| + | | Electric Box Sub-Assy | ||
| + | |- | ||
| + | | 43 | ||
| + | | Terminal Board | ||
| + | |- | ||
| + | | 44 | ||
| + | | Electric Box Assy | ||
| + | |- | ||
| + | | 45 | ||
| + | | Motor Support Sub-Assy | ||
| + | |- | ||
| + | | 46 | ||
| + | | Left Side Plate | ||
| + | |- | ||
| + | | 47 | ||
| + | | Condenser Support Plate | ||
| + | |- | ||
| + | | 48 | ||
| + | | Clapboard | ||
| + | |- | ||
| + | | 49 | ||
| + | | Fan Motor | ||
| + | |- | ||
| + | | 50 | ||
| + | | Axial Flow Fan | ||
|} | |} | ||
== Piping Sizes == | == Piping Sizes == | ||
Latest revision as of 13:58, 1 October 2014
A16CM4H4R42 is the 16 SEER, 42,000 Btu quint zone multi split unit.
Wiring Diagram
Exploded View and Parts List
| Number | Part Name |
|---|---|
| 1 | Front Grill |
| 2 | Cabinet |
| 3 | Front Side Plat Sub-Assy |
| 4 | Sensor Sub-Assy |
| 5 | Chassis Sub-Assy |
| 6 | Insulated Board (Cover of Electric Box) |
| 7 | Pressure Protect Switch |
| 8 | Compressor Mounting Plate Sub-Assy |
| 9 | Compressor and Fittings |
| 10 | Connection Pipe |
| 11 | Gas-Liquid Separator Sub-Assy |
| 12 | Bidirection Accumulator |
| 13 | Connecting Pipe of "U" Shape |
| 14 | Right Side Plate Sub-Assy |
| 15 | Strainer A |
| 16 | Cut-Off Valve |
| 17 | Cut-Off Valve |
| 18 | Strainer A |
| 19 | Valve Support Assy |
| 20 | Oil Separator |
| 21 | Tube Clip |
| 22 | Strainer A |
| 23 | 4-Way Valve |
| 24 | Handle |
| 25 | 4-Way Valve Assy |
| 26 | Pressure Protect Switch |
| 27 | Discharge Tube Sub-Assy |
| 28 | inhalation Tub Sub-Assy |
| 29 | Capillary Sub-Assy (Oil Separator) |
| 30 | Condenser Assy |
| 31 | Rear Grill |
| 32 | Electric Box Cover |
| 33 | Top Cover |
| 34 | Reactor Sub-Assy |
| 35 | Cover of Reactor Box |
| 36 | PFC Inductance |
| 37 | Reactor Box |
| 38 | Capacitor |
| 39 | Electric Box |
| 40 | Main Board |
| 41 | Radiator |
| 42 | Electric Box Sub-Assy |
| 43 | Terminal Board |
| 44 | Electric Box Assy |
| 45 | Motor Support Sub-Assy |
| 46 | Left Side Plate |
| 47 | Condenser Support Plate |
| 48 | Clapboard |
| 49 | Fan Motor |
| 50 | Axial Flow Fan |
Piping Sizes
| Liquid Side | Gas Side | Evaporators |
|---|---|---|
| 1/4" | 3/8" | A16EM4H4R09 A16EM4H4R12 |
| 1/4" | 1/2" | A16EM4H4R18 |
Malfunction Indicator
Note: When several malfunctions occur at the same time, they will be displayed in circulation and every malfunction is displayed for 5 seconds.
| NO. | Malfunction description | LED1 | LED2 | LED3 | LED4 |
| 0 | Normal stop | off | off | off | off |
| 1 | Compressor run | on | off | off | off |
| 2 | Compressor overload protection | blinking | off | off | off |
| 3 | Discharge protection | off | on | off | off |
| 4 | Outdoor unit overload protection | on | on | off | off |
| 5 | High pressure protection | blinking | on | off | off |
| 6 | Over current protection | off | blinking | off | off |
| 7 | IMP protection | on | blinking | off | off |
| 8 | IMP overheating protection | blinking | blinking | off | off |
| 9 | PFC protection (including PFC overheating protection) | off | off | on | off |
| 10 | Phase current protection | on | off | on | off |
| 11 | Over voltage protection | blinking | off | on | off |
| 12 | Insufficient voltage protection | off | on | on | off |
| 13 | Start failure | on | on | on | off |
| 14 | Compressor desynchronizing | blinking | on | on | off |
| 15 | Compressor phase-lacking protection | off | blinking | on | off |
| 16 | Compressor phase current detection malfunction | on | blinking | on | off |
| 17 | Memory chip mistake | blinking | blinking | on | off |
| 18 | DC power supply short-circuit | off | off | blinking | off |
| 19 | Defrosting | on | off | blinking | off |
| 20 | Oil return | blinking | off | blinking | off |
| 21 | Complete unit frequency restriction protection | off | on | blinking | off |
| 22 | Complete unit frequency dropping protection | on | on | blinking | off |
| 23 | Unit A frequency restriction or frequency dropping protection | blinking | on | blinking | off |
| 24 | Unit B frequency restriction or frequency dropping protection | off | blinking | blinking | off |
| 25 | Unit C frequency restriction or frequency dropping protection | on | blinking | blinking | off |
| 26 | Unit D frequency restriction or frequency dropping protection | blinking | blinking | blinking | off |
| 27 | Outdoor ambient temperature sensor protection | off | off | off | on |
| 28 | Outdoor tube temperature sensor protection | on | off | off | on |
| 29 | Discharge temperature sensor protection | blinking | off | off | on |
| 30 | IPM thermal resistance malfunction | off | on | off | on |
| 31 | Unit A liquid pipe temperature sensor malfunction | on | on | off | on |
| 32 | Unit A gas pipe temperature sensor malfunction | blinking | on | off | on |
| 33 | Unit B liquid pipe temperature sensor malfunction | off | blinking | off | on |
| 34 | Unit B gas pipe temperature sensor malfunction | on | blinking | off | on |
| 35 | Unit C liquid pipe temperature sensor malfunction | blinking | blinking | off | on |
| 36 | Unit C gas pipe temperature sensor malfunction | off | off | on | on |
| 37 | Unit D liquid pipe temperature sensor malfunction | on | off | on | on |
| 38 | Unit D gas pipe temperature sensor malfunction | blinking | off | on | on |
| 39 | Unit A mode conflict | off | on | on | on |
| 40 | Unit B mode conflict | on | on | on | on |
| 41 | Unit C mode conflict | blinking | on | on | on |
| 42 | Unit D mode conflict | off | blinking | on | on |
| 43 | Communication failure with Unit A | on | blinking | on | on |
| 44 | Communication failure with Unit B | blinking | blinking | on | on |
| 45 | Communication failure with Unit C | off | off | blinking | on |
| 46 | Communication failure with Unit D | on | off | blinking | on |
| 47 | Unit A freeze protection | blinking | off | blinking | on |
| 48 | Unit B freeze protection | off | on | blinking | on |
| 49 | Unit C freeze protection | on | on | blinking | on |
| 50 | Unit D freeze protection | blinking | on | blinking | on |
| 51 | Unit A overheating prevention protection | off | blinking | blinking | on |
| 52 | Unit B overheating prevention protection | on | blinking | blinking | on |
| 53 | Unit C overheating prevention protection | blinking | blinking | blinking | on |
| 54 | Unit D overheating prevention protection | off | off | off | blinking |
| 55 | Unit A communication wire misconnection or expansion valve malfunction | on | off | off | blinking |
| 56 | Unit B communication wire misconnection or expansion valve malfunction | blinking | off | off | blinking |
| 57 | Unit C communication wire misconnection or expansion valve malfunction | off | on | off | blinking |
| 58 | Unit D communication wire misconnection or expansion valve malfunction | on | on | off | blinking |
Common Troubleshooting
The following outline solutions for malfunctions that are either not indicated by the LEDs or cover more than one malfunction number in the above table.
- Capacity Charging Malfunction
- Anti-High Temperature and Overload Malfunction
- Temperature Sensor Malfunction
- Start Failure Malfunction
- Communication Malfunction
- Compressor Overload/Discharge Protection Malfunction