| 2
 +
| Antifreezing protection
 +
| E2
 +
| Off 3s and blink twice
 +
|
 +
|
 +
| On
 +
| Off
 +
| On
 +
| Off
 +
| During cooling and drying operation, compressor and outdoor fan stop while indoor fan operates.
 +
|
 +
* Poor air-return in indoor unit;
 +
* Fan speed is abnormal;
 +
* Evaporator is dirty;
 
|-
 
|-

Revision as of 17:37, 1 May 2014

NO. Malfunction Name Display Method of Indoor Unit Display Method of Outdoor Unit A/C Status Possible Causes
Dual-8 Code Display Indicator Display Indicator Display
Operation Indicator Cooling Indicator Heating Indicator D40/D5 D41/D6 D42/D16 D43/D30
1 System High Pressure Protection E1 3s off blink once off blinking blinking blinking During cooling and drying operation, all loads except the indoor fan stop operation. During heating operation, the entire unit stops.
  • Refrigerant was superabundant;
  • Poor heat exchange (including filth blockage of heat exchanger and bad radiating environment);
  • Ambient temperature is too high.
2 Antifreezing protection E2 Off 3s and blink twice On Off On Off During cooling and drying operation, compressor and outdoor fan stop while indoor fan operates.
  • Poor air-return in indoor unit;
  • Fan speed is abnormal;
  • Evaporator is dirty;