ACZCI4H4R09 is the 15 SEER 9,000 Btu outdoor unit of the Blue Series.

Blue Series condenser (9k)

Wiring Diagram

ACZCI4H4R09 Wiring Diagram

PCB Printed Diagram

ACZCI4H4R09 PCB Diagram
Number Description
1 Compressor UVW three phases
2 Reactor interface 2
3 Reactor interface 1
4 Fan interface
5 4-way valve interface
6 Power supply neutral wire
7 Power supply neutral wire
8 Communication wire
9 Overload input
10 Temperature sensor interface















Exploded View and Parts List

ACZCI4H4R09 Exploded View
Number Part Name
1 Front Grill
2 Cabinet
3 Chassis Sub-Assy
4 Compressor Gasket
5 Electrical Heater (Compressor)
6 Compressor and Fittings
7 Valve Support
8 Valve
9 Valve
10 Valve Cover
11 Cable Cross Plate 1
12 Cable Cross Plate 2
13 Right Side Plate
14 Cover of Pass Wire
15 4-Way Valve Assy
16 Magnet Coil
17 Temp Sensor Sleeving
18 Electric Expansion Valve Sub-Assy
19 Magnet Coil
20 Rear Grill
21 Condenser Assy
22 Compressor Overload Protector (External)
23 Clapboard Sub-Assy
24 Top Cover Plate
25 Cover of Reactor Box
26 Reactor
27 Reactor
28 Motor Support Spot Welding Sub-Assy
29 Fan Motor
30 Axial Flow Fan
31 Electric Box Cover Sub-Assy
32 Magnetic Ring
33 Main Board
34 Radiator
35 Electric Box 1
36 Terminal Board
37 Wire Clamp
38 Electric Box Assy
39 Temperature Sensor

Piping Sizes

Liquid Side Gas Side
1/4" 3/8"

Accessories