Difference between revisions of "Serene Plus Series Error Codes"
From Technical Support Wiki
(Created page with "{| class="wikitable" |- ! Code ! Reason ! Remark |- | E0 | IDU & ODU communication failure. | Check wiring between indoor and outdoor unit. |- |}") |
|||
| Line 8: | Line 8: | ||
| IDU & ODU communication failure. | | IDU & ODU communication failure. | ||
| Check wiring between indoor and outdoor unit. | | Check wiring between indoor and outdoor unit. | ||
| + | |- | ||
| + | | E1 | ||
| + | | IDU room temperature sensor failure. | ||
| + | | Check IDU room temperature sensor and IDU PCB. | ||
| + | |- | ||
| + | | E2 | ||
| + | | IDU coil temperature sensor failure. | ||
| + | | Check IDU coil tempeature sensor and IDU PCB. | ||
| + | |- | ||
| + | | E3 | ||
| + | | ODU coil temperature sensor failure. | ||
| + | | Check ODU coil temperature sensor and ODU PCB. | ||
| + | |- | ||
| + | | E4 | ||
| + | | AC cooling system abnormal. | ||
| + | | Check for refrigerant leakage, 2-way or 3-way valve blockage, etc. | ||
| + | |- | ||
| + | | E5 | ||
| + | | IDU/ODU mismatch failure. | ||
| + | | IDU and ODU model number mismatch. | ||
| + | |- | ||
| + | | E6 | ||
| + | | IDU PG fan motor / DC fan motor abnormality. | ||
| + | | Check fan motor, fan blade and PCB. | ||
| + | |- | ||
| + | | E7 | ||
| + | | ODU ambient temperature sensor failure. | ||
| + | | Check ODU ambient temperature sensor and ODU PCB. | ||
| + | |- | ||
| + | | E8 | ||
| + | | ODU discharge temperature sensor failure. | ||
| + | | Check ODU discharge temperature sensor and ODU PCB. | ||
| + | |- | ||
| + | | E9 | ||
| + | | IPM / Compressor driving control abnormal. | ||
| + | | Check ODU PCB and compressor. | ||
| + | |- | ||
| + | | EA | ||
| + | | ODU current test circuit failure. | ||
| + | | Check ODU PCB. | ||
| + | |- | ||
| + | | Eb | ||
| + | | Communication abnormal between IDU PCB and IDU display board. | ||
| + | | Check display board and IDU PCB. | ||
| + | |- | ||
| + | | EE | ||
| + | | ODU EEPROM failure. | ||
| + | | Check ODU PCB or re-power AC unit. | ||
| + | |- | ||
| + | | EF | ||
| + | | ODU DC fan motor failure. | ||
| + | | Check ODU fan motor or ODU PCB. | ||
| + | |- | ||
| + | | EU | ||
| + | | ODU voltage test circuit abnormal. | ||
| + | | Check ODU PCB. | ||
| + | |- | ||
| + | | P0 | ||
| + | | IPM module protection | ||
| + | | Check ODU PCB. | ||
| + | |- | ||
| + | | P1 | ||
| + | | Over / under voltage protection. | ||
| + | | Check ODU PCB and power supply. | ||
|- | |- | ||
|} | |} | ||
Revision as of 15:25, 15 January 2026
| Code | Reason | Remark |
|---|---|---|
| E0 | IDU & ODU communication failure. | Check wiring between indoor and outdoor unit. |
| E1 | IDU room temperature sensor failure. | Check IDU room temperature sensor and IDU PCB. |
| E2 | IDU coil temperature sensor failure. | Check IDU coil tempeature sensor and IDU PCB. |
| E3 | ODU coil temperature sensor failure. | Check ODU coil temperature sensor and ODU PCB. |
| E4 | AC cooling system abnormal. | Check for refrigerant leakage, 2-way or 3-way valve blockage, etc. |
| E5 | IDU/ODU mismatch failure. | IDU and ODU model number mismatch. |
| E6 | IDU PG fan motor / DC fan motor abnormality. | Check fan motor, fan blade and PCB. |
| E7 | ODU ambient temperature sensor failure. | Check ODU ambient temperature sensor and ODU PCB. |
| E8 | ODU discharge temperature sensor failure. | Check ODU discharge temperature sensor and ODU PCB. |
| E9 | IPM / Compressor driving control abnormal. | Check ODU PCB and compressor. |
| EA | ODU current test circuit failure. | Check ODU PCB. |
| Eb | Communication abnormal between IDU PCB and IDU display board. | Check display board and IDU PCB. |
| EE | ODU EEPROM failure. | Check ODU PCB or re-power AC unit. |
| EF | ODU DC fan motor failure. | Check ODU fan motor or ODU PCB. |
| EU | ODU voltage test circuit abnormal. | Check ODU PCB. |
| P0 | IPM module protection | Check ODU PCB. |
| P1 | Over / under voltage protection. | Check ODU PCB and power supply. |