Difference between revisions of "ABSEM4H4S12"

From Technical Support Wiki
Jump to: navigation, search
 
Line 106: Line 106:
  
 
== Exploded View and Parts List ==  
 
== Exploded View and Parts List ==  
[[File:Blue2-9-12k-IDU-EV.png|left|thumb|500px|ABSEM4H4S12 Exploded View]]
+
[[File:Blue2-9-12k-IDU-EV.png|center|thumb|500px|ABSEM4H4S12 Exploded View]]
 
{| class="wikitable"
 
{| class="wikitable"
 
! Number
 
! Number

Latest revision as of 14:53, 11 April 2022

ABSEM4H4S09 is the 21 SEER 12,000 Btu indoor unit of Blue Series 2.

Blue Series 2 evaporator (12k)

Remote Control

Remote Control
# Name Description
1 ON/OFF Press to start or stop operation.
2 MODE Press to select operation mode (Auto/Cool/Dry/Fan/Heat).
3 FAN Used to select the fan speed in sequence: auto, high, medium, or low.
4 ROOM TEMPERATURE SETTING Press to raise the temperature setting. Can also be used to adjust the timer and adjust the current time.
5 ROOM TEMPERATURE SETTING Press to lower the temperature setting. Can also be used to adjust the timer and adjust the current time.
6 SMART Adjust smart settings.
7 SWING Used to stop or start vertical adjustment louver swinging and set the desired up/down airflow direction.
8 SLEEP Used to set or cancel Sleep Mode operation.
9 IFEEL Used to set IFEEL operation.
10 CLOCK Used to set the current time.
11 TIMER ON Used to turn the timer function on.
12 TIMER OFF Used to turn the timer function off.
13 SUPER Used to start/stop the super cool/heat function. (Super cooling operates at high fan speed with a default 64 F temperature setting. Super heating operates at high fan speed with a default 89 F temperature setting.)
14 DIMMER Pressing this button will dim the display on the indoor unit. Pressing any button will reverse the dimmer.

Wiring Diagram

ABSEM4H4S12 Wiring Diagram

PCB Printed Diagram

ABSEM4H4S12 PCB Printed Diagram
Number Description
1 PG Motor Interface
2 Room temperature sensor
3 Pipe temperature sensor
4 Switch buton
5 Feedback from PG Motor
6 Up & down swing
7 Left & right swing
8 Wiring control or Wifi interface
9 Display interface
10 Protective tube



Exploded View and Parts List

ABSEM4H4S12 Exploded View
Number Part Name Part Number
1 Installation Plate Assy 1465589
2 Baffle 1465666
3 Base Holder Part 1854439
4 Vertical Level Vane 1555378
5 Center Staff 1555381
6 Center Staff 1555385
7 Center Staff 1555387
8 Step Motor 1260259
9 Motor Guard 1465756
10 Level Vane 1555374
11 Cross-Flow Fan Blade 1466014
12 Bearing 1223739
13 Baffle 1465670
14 Refrigeration System 1902702
15 Motor Guard 1555386
16 Fan Motor 1857574
17 Motor Cover 1465757
18 Remote Controller 1854426
19 Electric Box Cover 1465763
20 Temperature Sensor 1387643
21 Temperature Sensor 1471151
22 Over Clamp 1839902
23 Wire Terminal Board 1852126
24 Electric Box Cover 1840039
25 Electric Joint Box Plate 1465761
26 Indoor Main Control Board Component1 1871037
27 Electric Box 1868909
28 Electric Joint Box Plate 1465762
29 Water Pipe Parts 1470426
30 Axis Sheath 1222824
31 Step Motor 1468408
32 Shell 1816270
33 Display Component 1844146
34 Ornamental Part 1826489
35 Panel 1819198
Unnumbered Filter Net 1506312

1IDU control board had a revision in March 2018.