Difference between revisions of "Multi Plus IDU Combination Table"

From Technical Support Wiki
Jump to: navigation, search
Line 1: Line 1:
{| class="wikitable sortable"
+
{| class="wikitable"
 
|-
 
|-
 
! ODU Model
 
! ODU Model

Revision as of 12:43, 22 June 2020

ODU Model Combination of IDUs Cooling Capacity Heating Capacity
A B C D Total Capacity (BTU/h) Power Input (W) (A) SEER EER A B C D Total Capacity (BTU/h) Power Input (W) (A) SCOP cop
BTU/h BTU/h BTU/h BTU/h NOM MIN MAX NOM MIN MAX W/W BTU/h BTU/h BTU/h BTU/h NOM MIN MAX NOM MIN MAX W/W
AMSCI4H4S18 09+09 9000 9000 18000 7500 24000 1440 510 2610 6.5 22.0 3.66 9000 9000 18000 5800 28700 1530 450 3150 6.9 11.0 3.45
09+12 8500 9500 18000 7500 24000 1440 510 2610 6.5 22.0 3.66 8500 9500 18000 5800 28700 1530 450 3150 6.9 11.0 3.45
12+12 9000 9000 18000 7500 24000 1440 510 2610 6.5 22.0 3.66 9000 9000 18000 5800 28700 1530 450 3150 6.9 11.0 3.45
AMSCI4H4S24 09+09 8900 8900 17800 7200 24000 1645 400 2200 7.6 18.0 3.17 8900 8900 17800 4400 25000 1715 400 3400 7.9 9.50 3.04