Difference between revisions of "AMXEK4H4S18"

From Technical Support Wiki
Jump to: navigation, search
 
Line 71: Line 71:
 
! Part Description
 
! Part Description
 
|-
 
|-
 
+
| 1
 +
| Base Plate
 +
|-
 +
| 2
 +
| Bottom Plate
 +
|-
 +
| 3
 +
| Water Drain
 +
|-
 +
| 4
 +
| Evaporator
 +
|-
 +
| 5
 +
| Supporting
 +
|-
 +
| 6
 +
| Electric Box Cover
 +
|-
 +
| 7
 +
| Seal Plate
 +
|-
 +
| 8
 +
| Right Side Board
 +
|-
 +
| 9
 +
| Water Position Switch
 +
|-
 +
| 10
 +
| Temperature Sensor
 +
|-
 +
| 11
 +
| Temperature Sensor
 +
|-
 +
| 12
 +
| Fan Board
 +
|-
 +
| 13
 +
| Motor Supporter
 +
|-
 +
| 14
 +
| Fan Snail Shell
 +
|-
 +
| 15
 +
| Fan
 +
|-
 +
| 16
 +
| Bearing
 +
|-
 +
| 17
 +
| Axes
 +
|-
 +
| 18
 +
| Crosshead
 +
|-
 +
| 19
 +
| Hooking
 +
|-
 +
| 20
 +
| Connecting Rod
 +
|-
 +
| 21
 +
| Hooking
 +
|-
 +
| 22
 +
| DC Motor
 +
|-
 +
| 23
 +
| Elec Joint Box
 +
|-
 +
| 24
 +
| Electric Box
 +
|-
 +
| 25
 +
| Main Control Board
 +
|-
 
|}
 
|}
 
== PCB Printed Diagram ==  
 
== PCB Printed Diagram ==  
 
[[File:MP-Duct-Type-IDU-PCB.png|right|thumb|500px|AMXEK4H4S18 PCB Printed Diagram]]
 
[[File:MP-Duct-Type-IDU-PCB.png|right|thumb|500px|AMXEK4H4S18 PCB Printed Diagram]]

Latest revision as of 17:12, 30 September 2019

AMXEK4H4S18 is the 18,000 Btu duct type indoor unit of Multi Plus Series.

Multi Plus evaporator (18k)

Remote Control

Remote Control
# Name Description
1 ON/OFF Press to start or stop operation.
2 MODE Press to select operation mode (Auto/Cool/Dry/Fan/Heat).
3 FAN Used to select the fan speed in sequence: auto, high, medium, or low.
4 ROOM TEMPERATURE SETTING Press to raise the temperature setting. Can also be used to adjust the timer and adjust the current time.
5 ROOM TEMPERATURE SETTING Press to lower the temperature setting. Can also be used to adjust the timer and adjust the current time.
6 SMART Adjust smart settings.
7 SWING Used to stop or start vertical adjustment louver swinging and set the desired up/down airflow direction.
8 SLEEP Used to set or cancel Sleep Mode operation.
9 IFEEL Used to set IFEEL operation.
10 CLOCK Used to set the current time.
11 TIMER ON Used to turn the timer function on.
12 TIMER OFF Used to turn the timer function off.
13 SUPER Used to start/stop the super cool/heat function. (Super cooling operates at high fan speed with a default 64 F temperature setting. Super heating operates at high fan speed with a default 89 F temperature setting.)
14 DIMMER Pressing this button will dim the display on the indoor unit. Pressing any button will reverse the dimmer.

Wiring Diagram

AMXEK4H4S18 Wiring Diagram

Exploded View and Parts List

AMXEK4H4S18 Exploded View
Number Part Description
1 Base Plate
2 Bottom Plate
3 Water Drain
4 Evaporator
5 Supporting
6 Electric Box Cover
7 Seal Plate
8 Right Side Board
9 Water Position Switch
10 Temperature Sensor
11 Temperature Sensor
12 Fan Board
13 Motor Supporter
14 Fan Snail Shell
15 Fan
16 Bearing
17 Axes
18 Crosshead
19 Hooking
20 Connecting Rod
21 Hooking
22 DC Motor
23 Elec Joint Box
24 Electric Box
25 Main Control Board

PCB Printed Diagram

AMXEK4H4S18 PCB Printed Diagram