Line 278: | Line 278: | ||
* Replace the outdoor control board | * Replace the outdoor control board | ||
|- | |- | ||
− | + | | 45 | |
+ | | IPM fault | ||
+ | | Please refer to "drive board fault codes" for more information | ||
+ | | Please refer to "drive board fault codes" for more information | ||
+ | |- | ||
+ | | 46 | ||
+ | | IPM and control board communication fault | ||
+ | | | ||
+ | * The cable between the control board and the driver board is loose | ||
+ | * The cable between the control board and the driver board has failed | ||
+ | * The driver board has failed | ||
+ | * The control board has failed | ||
+ | | | ||
+ | * Reconnect the cable between the control board and the driver board | ||
+ | * Replace the communication cable between the control board and the driver board | ||
+ | * Replace the driver board | ||
+ | * Replace the control board | ||
+ | |- | ||
+ | | 47 | ||
+ | | Discharge temperature too high fault | ||
+ | | | ||
+ | * Insufficient amount of refrigerant | ||
+ | * The refrigerant of the unit is not enough due to additional length of the installation pipe | ||
+ | * Throttling service has failed | ||
+ | * The outdoor ambient temperature is too high | ||
+ | | | ||
+ | * Check for refrigerant leaks. Fix leak and re-add refrigerant | ||
+ | * Add refrigerant according to additional installation pipe length | ||
+ | * Replace the throttling service (such as capillary, expansion valve) | ||
+ | |- | ||
+ | | 48 | ||
+ | | Outdoor DC fan motor fault (upper fan motor) | ||
+ | | | ||
+ | * The wiring of the upper DC fan motor is loose | ||
+ | * The cord of the upper DC fan motor has failed | ||
+ | * The upper DC fan motor has failed | ||
+ | * The drive circuit of the upper DC fan motor has failed | ||
+ | * The outdoor fan has been blocked | ||
+ | | | ||
+ | * Reconnect the wiring of the upper DC fan motor | ||
+ | * Replace the upper DC fan motor | ||
+ | * Replace the driver board of the fan motor | ||
+ | * Check the outdoor fan and ensure the outdoor fan can run normally | ||
+ | |- | ||
+ | | 49 | ||
+ | | Outdoor DC fan motor fault (lower fan motor) | ||
+ | | | ||
+ | * The wiring of the lower DC fan motor is loose | ||
+ | * The cord of the lower DC fan motor has failed | ||
+ | * The lower DC fan motor has failed | ||
+ | * The drive circuit of the lower DC fan motor has failed | ||
+ | * The outdoor fan has been blocked | ||
+ | | | ||
+ | * Reconnect the wiring of the lower DC fan motor | ||
+ | * Replace the lower DC fan motor | ||
+ | * Replace the driver board of the fan motor | ||
+ | * Check the outdoor fan and ensure the outdoor fan can run normally | ||
+ | |- | ||
+ | | 91 | ||
+ | | The unit turned off due to the IPM board over heating fault | ||
+ | | | ||
+ | * The outdoor ambient temperature is too high | ||
+ | * The speed of the outdoor fan motor is too low | ||
+ | * The outdoor unit has been installed incorrectly | ||
+ | * The supply power is too low | ||
+ | | | ||
+ | * Check the fan capacitor, and replace the fan capacitor if it has failed | ||
+ | * Reinstall the outdoor unit by referring to the installation user manual | ||
+ | |- | ||
+ | | 96 | ||
+ | | The refrigerant of the unit is not enough fault | ||
+ | | Insufficient amount of refrigerant | ||
+ | | | ||
+ | * Check for leaks | ||
+ | * Charge refrigerant to recommended levels | ||
+ | |- | ||
+ | | 97 | ||
+ | | 4-way valve communication failure fault | ||
+ | | | ||
+ | * The wiring of the 4-way valve coil is loose | ||
+ | * The 4-way valve coil has failed | ||
+ | * The 4-way valve has failed | ||
+ | * The driver board of the 4-way valve has failed | ||
+ | | | ||
+ | * Reconnect the wiring of the 4-way valve | ||
+ | * Replace the 4-way valve coil | ||
+ | * Replace the 4-way valve | ||
+ | * Replace the driver board of the 4-way valve | ||
|} | |} | ||
Go back to [[Multi Plus]] page | Go back to [[Multi Plus]] page |
Revision as of 12:59, 26 September 2019
Fault Code | Fault Description | Possible Reason for Fault | Potential Fixes |
---|---|---|---|
1 | Outdoor Ambient Temperature Sensor Fault |
|
|
2 | Outdoor Coil Temperature Sensor Fault |
|
|
3 | The Unit Over-Current Turn Off Fault |
|
|
4 | EEprom Data Error |
|
|
5 | Cooling Freezing
Protection (the indoor coil temperature is too low) or Heating Overload (indoor coil temperature is too high) |
|
|
7 | Communication fault between the indoor unit and outdoor unit |
outdoor unit is poor
|
|
13 | Compressor overheat protector device |
|
overload protector
protector
board |
14 | The high pressure switch operates or the unit turns off for high pressure protection |
|
|
15 | Low pressure switch protection or the unit turned off for low pressure protection |
|
board |
16 | Overload protection in cooling mode | System Overload | Refer to "Overload in Cooling Mode addendum" |
17 | Discharge temperature sensor fault |
|
|
18 | AC voltage is abnormal |
|
|
19 | Suction temperature sensor fault |
|
|
22 | Defrosting sensor fault |
|
|
23 | Expansion valve A tube (thin) sensor fault |
|
|
24 | Expansion valve B tube (thin) sensor fault |
|
|
25 | Expansion valve C tube (thin) sensor fault |
|
|
26 | Expansion valve D tube (thin) sensor fault |
|
|
27 | Expansion valve A tube (thick) sensor fault |
|
|
28 | Expansion valve B tube (thick) sensor fault |
|
|
29 | Expansion valve C tube (thick) sensor fault |
|
|
30 | Expansion valve D tube (thick) sensor fault |
|
|
45 | IPM fault | Please refer to "drive board fault codes" for more information | Please refer to "drive board fault codes" for more information |
46 | IPM and control board communication fault |
|
|
47 | Discharge temperature too high fault |
|
|
48 | Outdoor DC fan motor fault (upper fan motor) |
|
|
49 | Outdoor DC fan motor fault (lower fan motor) |
|
|
91 | The unit turned off due to the IPM board over heating fault |
|
|
96 | The refrigerant of the unit is not enough fault | Insufficient amount of refrigerant |
|
97 | 4-way valve communication failure fault |
|
|