Revision as of 13:53, 25 September 2019

Type Up to 3 Indoor Units Up to 4 Indoor Units
Model Name AMSCI4H4S24 AMSCI4H4S36
Gas R410A R410A
Capacity Cooling Capacity 95°F BTU/h 24000 32000
Heating Rated Capacity 47°F BTU/h 24000 36000
17°F BTU/h 15400 22800
Heating Maximum Capacity 17°F BTU/h 26000 40000
5°F BTU/h 24000 36000
Cooling 95°F BTU/h 24000(8000-30200) 32000(12000-42000)
Heating 47°F BTU/h 24000(5200-37000) 36000(8000-52000)
Air Flow m3/h 4000 5000
CFM 2350 2941
EER 95°F BTU/Wh 12.5 12.5
COP 47°F BTU/Wh 3.66 3.37
SEER BTU/Wh 22.0 21.0
HSPF BTU/Wh 11.0 11.0
Noise Level (Max) dB(A) 59 59
Operating Range Cooling °F 14-114.8 14-114.8
Heating °F (-13)-75.2 (-13)-75.2
Compressor Model Model EATF250D22UMT EATF400D42UMTA
Brand GMCC GMCC