Difference between revisions of "MHI KXZ ODU1"
From Technical Support Wiki
| Line 50: | Line 50: | ||
| colspan="3" style="text-align: center;" | 3 Phase 380V, 60Hz | | colspan="3" style="text-align: center;" | 3 Phase 380V, 60Hz | ||
|- | |- | ||
| + | | colspan="4" | Starting Current | ||
| + | | A | ||
| + | | colspan="6" style="text-align: center;" | 5 | ||
| + | |- | ||
| + | | colspan="4" | Max Current | ||
| + | | A | ||
| + | | colspan="2" style="text-align: center;" | 23 | ||
| + | | 23.3 | ||
| + | | colspan="3" style="text-align: center;" | 13.5 | ||
| + | |- | ||
| + | | colspan="2" rowspan="2" | Nominal Capacity | ||
| + | | colspan="2" | Cooling | ||
| + | | rowspan="2" | kW | ||
| + | | 11.2 | ||
| + | | 14.0 | ||
| + | | 15.5 | ||
| + | | 11.2 | ||
| + | | 14.0 | ||
| + | | 15.5 | ||
| + | |- | ||
| + | | colspan="2" | Heating | ||
| + | | 12.5 | ||
| + | | 16.0 | ||
| + | | 16.3 | ||
| + | | 12.5 | ||
| + | | 16.0 | ||
| + | | 16.3 | ||
| + | |- | ||
| + | |||
|} | |} | ||
Revision as of 20:34, 19 November 2018
This is the support page for the Micro Model Heat Pump outdoor units for MHI VRF air conditioners.
| Micro Model Heat Pump Systems (FDC) | |
| Voltage | 220V-380V |
|---|---|
| Capacities (kW) | 11.2-15.5 |
| Heat Pump? | Yes |
Model Numbers
- FDC112KXEN6
- FDC140KXEN6
- FDC155KXEN6
- FDC112KXES6
- FDC140KXES6
- FDC155KXES6
Specifications
| Item | Unit | FDC112KXEN6 | FDC140KXEN6 | FDC155KXEN6 | FDC112KXES6 | FDC140KXES6 | FDC155KXES6 | |||
|---|---|---|---|---|---|---|---|---|---|---|
| Nominal Horse Power | 4HP | 5HP | 6HP | 4HP | 5HP | 6HP | ||||
| Power Source | 1 Phase 220V, 60Hz | 3 Phase 380V, 60Hz | ||||||||
| Starting Current | A | 5 | ||||||||
| Max Current | A | 23 | 23.3 | 13.5 | ||||||
| Nominal Capacity | Cooling | kW | 11.2 | 14.0 | 15.5 | 11.2 | 14.0 | 15.5 | ||
| Heating | 12.5 | 16.0 | 16.3 | 12.5 | 16.0 | 16.3 | ||||