Line 205: | Line 205: | ||
| blinking | | blinking | ||
| blinking | | blinking | ||
+ | | off | ||
|- | |- | ||
+ | | 27 | ||
+ | | Outdoor ambient temperature sensor protection | ||
+ | | off | ||
+ | | off | ||
+ | | off | ||
+ | | on | ||
+ | |- | ||
+ | | 28 | ||
+ | | Outdoor tube temperature sensor protection | ||
+ | | on | ||
+ | | off | ||
+ | | off | ||
+ | | on | ||
+ | |- | ||
+ | | 29 | ||
+ | | Discharge temperature sensor protection | ||
+ | | blinking | ||
+ | | off | ||
+ | | off | ||
+ | | on | ||
+ | |- | ||
+ | | 30 | ||
+ | | IPM thermal resistance malfunction | ||
+ | | off | ||
+ | | on | ||
+ | | off | ||
+ | | on | ||
+ | |- | ||
+ | | 31 | ||
+ | | Unit A liquid pipe temperature sensor malfunction | ||
+ | | on | ||
+ | | on | ||
+ | | off | ||
+ | | on | ||
+ | |- | ||
+ | | 32 | ||
+ | | Unit A gas pipe temperature sensor malfunction | ||
+ | | blinking | ||
+ | | on | ||
+ | | off | ||
+ | | on | ||
+ | |- | ||
+ | | 33 | ||
+ | | Unit B liquid pipe temperature sensor malfunction | ||
+ | | off | ||
+ | | blinking | ||
+ | | off | ||
+ | | on | ||
+ | |- | ||
+ | | 34 | ||
+ | | Unit B gas pipe temperature sensor malfunction | ||
+ | | on | ||
+ | | blinking | ||
+ | | off | ||
+ | | on | ||
+ | |- | ||
+ | | 35 | ||
+ | | Unit C liquid pipe temperature sensor malfunction | ||
+ | | blinking | ||
+ | | blinking | ||
+ | | off | ||
+ | | on | ||
+ | |- | ||
+ | | 36 | ||
+ | | Unit C gas pipe temperature sensor malfunction | ||
+ | | off | ||
+ | | off | ||
+ | | on | ||
+ | | on | ||
+ | |- | ||
+ | | 37 | ||
+ | | Unit D liquid pipe temperature sensor malfunction | ||
+ | | on | ||
+ | | off | ||
+ | | on | ||
+ | | on | ||
+ | |- | ||
+ | | 38 | ||
+ | | Unit D gas pipe temperature sensor malfunction | ||
+ | | blinking | ||
+ | | off | ||
+ | | on | ||
+ | | on | ||
+ | |- | ||
+ | | 39 | ||
+ | | Unit A mode conflict | ||
+ | | off | ||
+ | | on | ||
+ | | on | ||
+ | | on | ||
+ | |- | ||
+ | | 40 | ||
+ | | Unit B mode conflict | ||
+ | | on | ||
+ | | on | ||
+ | | on | ||
+ | | on | ||
+ | |- | ||
+ | | 41 | ||
+ | | Unit C mode conflict | ||
+ | | blinking | ||
+ | | on | ||
+ | | on | ||
+ | | on | ||
+ | |- | ||
+ | | 42 | ||
+ | | Unit D mode conflict | ||
+ | | off | ||
+ | | blinking | ||
+ | | on | ||
+ | | on | ||
+ | |- | ||
+ | | 43 | ||
+ | | Communication failure with Unit A | ||
+ | | on | ||
+ | | blinking | ||
+ | | on | ||
+ | | on | ||
+ | |- | ||
+ | | 44 | ||
+ | | Communication failure with Unit B | ||
+ | | blinking | ||
+ | | blinking | ||
+ | | on | ||
+ | | on | ||
+ | |- | ||
+ | | 45 | ||
+ | | Communication failure with Unit C | ||
+ | | off | ||
+ | | off | ||
+ | | blinking | ||
+ | | on | ||
+ | |- | ||
+ | | 46 | ||
+ | | Communication failure with Unit D | ||
+ | | on | ||
+ | | off | ||
+ | | blinking | ||
+ | | on | ||
+ | |- | ||
+ | | 47 | ||
+ | | Unit A freeze protection | ||
+ | | blinking | ||
+ | | off | ||
+ | | blinking | ||
+ | | on | ||
+ | |- | ||
+ | | 48 | ||
+ | | Unit B freeze protection | ||
+ | | off | ||
+ | | on | ||
+ | | blinking | ||
+ | | on | ||
+ | |- | ||
+ | | 49 | ||
+ | | Unit C freeze protection | ||
+ | | on | ||
+ | | on | ||
+ | | blinking | ||
+ | | on | ||
+ | |- | ||
+ | | 50 | ||
+ | | Unit D freeze protection | ||
+ | | blinking | ||
+ | | on | ||
+ | | blinking | ||
+ | | on | ||
+ | |- | ||
+ | | 51 | ||
+ | | Unit A overheating prevention protection | ||
+ | | off | ||
+ | | blinking | ||
+ | | blinking | ||
+ | | on | ||
+ | |- | ||
+ | | 52 | ||
+ | | Unit B overheating prevention protection | ||
+ | | on | ||
+ | | blinking | ||
+ | | blinking | ||
+ | | on | ||
+ | |- | ||
+ | | 53 | ||
+ | | Unit C overheating prevention protection | ||
+ | | blinking | ||
+ | | blinking | ||
+ | | blinking | ||
+ | | on | ||
+ | |- | ||
+ | | 54 | ||
+ | | Unit D overheating prevention protection | ||
+ | | off | ||
+ | | off | ||
+ | | off | ||
+ | | blinking | ||
+ | |- | ||
+ | | 55 | ||
+ | | Unit A communication wire misconnection or expansion valve malfunction | ||
+ | | on | ||
+ | | off | ||
+ | | off | ||
+ | | blinking | ||
+ | |- | ||
+ | | 56 | ||
+ | | Unit B communication wire misconnection or expansion valve malfunction | ||
+ | | blinking | ||
+ | | off | ||
+ | | off | ||
+ | | blinking | ||
+ | |- | ||
+ | | 57 | ||
+ | | Unit C communication wire misconnection or expansion valve malfunction | ||
+ | | off | ||
+ | | on | ||
+ | | off | ||
+ | | blinking | ||
+ | |- | ||
+ | | 58 | ||
+ | | Unit D communication wire misconnection or expansion valve malfunction | ||
+ | | on | ||
+ | | on | ||
+ | | off | ||
+ | | blinking | ||
|} | |} | ||
== Warranty Information == | == Warranty Information == |
Revision as of 15:29, 11 November 2013
This is the support page for the Air-Con multi split line. Here you will find information pertaining to common issues with the multi split units.
Indoor Units
Outdoor Units
Malfunction Indicators
NO. | Malfunction description | LED1 | LED2 | LED3 | LED4 |
0 | Normal stop | off | off | off | off |
1 | Compressor run | on | off | off | off |
2 | Compressor overload protection | blinking | off | off | off |
3 | Discharge protection | off | on | off | off |
4 | Outdoor unit overload protection | on | on | off | off |
5 | High pressure protection | blinking | on | off | off |
6 | Over current protection | off | blinking | off | off |
7 | IMP protection | on | blinking | off | off |
8 | IMP overheating protection | blinking | blinking | off | off |
9 | PFC protection (including PFC overheating protection) | off | off | on | off |
10 | Phase current protection | on | off | on | off |
11 | Over voltage protection | blinking | off | on | off |
12 | Insufficient voltage protection | off | on | on | off |
13 | Start failure | on | on | on | off |
14 | Compressor desynchronizing | blinking | on | on | off |
15 | Compressor phase-lacking protection | off | blinking | on | off |
16 | Compressor phase current detection malfunction | on | blinking | on | off |
17 | Memory chip mistake | blinking | blinking | on | off |
18 | DC power supply short-circuit | off | off | blinking | off |
19 | Defrosting | on | off | blinking | off |
20 | Oil return | blinking | off | blinking | off |
21 | Complete unit frequency restriction protection | off | on | blinking | off |
22 | Complete unit frequency dropping protection | on | on | blinking | off |
23 | Unit A frequency restriction or frequency dropping protection | blinking | on | blinking | off |
24 | Unit B frequency restriction or frequency dropping protection | off | blinking | blinking | off |
25 | Unit C frequency restriction or frequency dropping protection | on | blinking | blinking | off |
26 | Unit D frequency restriction or frequency dropping protection | blinking | blinking | blinking | off |
27 | Outdoor ambient temperature sensor protection | off | off | off | on |
28 | Outdoor tube temperature sensor protection | on | off | off | on |
29 | Discharge temperature sensor protection | blinking | off | off | on |
30 | IPM thermal resistance malfunction | off | on | off | on |
31 | Unit A liquid pipe temperature sensor malfunction | on | on | off | on |
32 | Unit A gas pipe temperature sensor malfunction | blinking | on | off | on |
33 | Unit B liquid pipe temperature sensor malfunction | off | blinking | off | on |
34 | Unit B gas pipe temperature sensor malfunction | on | blinking | off | on |
35 | Unit C liquid pipe temperature sensor malfunction | blinking | blinking | off | on |
36 | Unit C gas pipe temperature sensor malfunction | off | off | on | on |
37 | Unit D liquid pipe temperature sensor malfunction | on | off | on | on |
38 | Unit D gas pipe temperature sensor malfunction | blinking | off | on | on |
39 | Unit A mode conflict | off | on | on | on |
40 | Unit B mode conflict | on | on | on | on |
41 | Unit C mode conflict | blinking | on | on | on |
42 | Unit D mode conflict | off | blinking | on | on |
43 | Communication failure with Unit A | on | blinking | on | on |
44 | Communication failure with Unit B | blinking | blinking | on | on |
45 | Communication failure with Unit C | off | off | blinking | on |
46 | Communication failure with Unit D | on | off | blinking | on |
47 | Unit A freeze protection | blinking | off | blinking | on |
48 | Unit B freeze protection | off | on | blinking | on |
49 | Unit C freeze protection | on | on | blinking | on |
50 | Unit D freeze protection | blinking | on | blinking | on |
51 | Unit A overheating prevention protection | off | blinking | blinking | on |
52 | Unit B overheating prevention protection | on | blinking | blinking | on |
53 | Unit C overheating prevention protection | blinking | blinking | blinking | on |
54 | Unit D overheating prevention protection | off | off | off | blinking |
55 | Unit A communication wire misconnection or expansion valve malfunction | on | off | off | blinking |
56 | Unit B communication wire misconnection or expansion valve malfunction | blinking | off | off | blinking |
57 | Unit C communication wire misconnection or expansion valve malfunction | off | on | off | blinking |
58 | Unit D communication wire misconnection or expansion valve malfunction | on | on | off | blinking |