Capacity (BTU/h) Pipe Size Standard Length (ft) Max Elevation (ft) Max Length (ft) Additional Refrigerant (oz/ft)
Gas Liquid
5k~14k 3/8" 1/4" 25 23 50 0.70
1/2" 1/4" 25 23 50 0.70
18k~28k 1/2" 1/4" 25 50 98 0.70
5/8" 1/4" 25 50 98 0.70
5/8" 3/8" 25 50 98 1.05
30k~38k 5/8" 3/8" 25 50 98 1.05
3/4" 3/8" 25 50 98 1.76