Difference between revisions of "ABSEM4H4S09"

From Technical Support Wiki
Jump to: navigation, search
(Created page with "ABSEM4H4S09 is the 22 SEER 9,000 Btu indoor unit of ''Blue Series 2''. right|thumb|''Blue Series 2'' evaporator (9k) == Remote Control == File:RC-...")
 
 
(9 intermediate revisions by the same user not shown)
Line 1: Line 1:
ABSEM4H4S09 is the 22 SEER 9,000 Btu indoor unit of ''[[Blue Series 2]]''. [[File:Blue-evap.png|right|thumb|''Blue Series 2'' evaporator (9k)]]
+
ABSEM4H4S09 is the 22 SEER 9,000 Btu indoor unit of ''[[Blue Series 2]]''. [[File:Blue2-9-24k-evap.png|right|thumb|''Blue Series 2'' evaporator (9k)]]
 
== Remote Control ==
 
== Remote Control ==
[[File:RC-BSU.png|left|thumb|100px|Remote Control]]
+
[[File:Blue-series-2-remote.png|left|thumb|200px|Remote Control]]
 
{| class="wikitable"
 
{| class="wikitable"
 
| #
 
| #
Line 15: Line 15:
 
| Press to select operation mode (Auto/Cool/Dry/Fan/Heat).
 
| Press to select operation mode (Auto/Cool/Dry/Fan/Heat).
 
|-
 
|-
| 3  
+
| 3
| + (Raise)
+
| FAN
| Press to raise the temperature setting.
+
| Used to select the fan speed in sequence: auto, high, medium, or low.
 +
|-
 +
| 4
 +
| ROOM TEMPERATURE SETTING
 +
| Press to raise the temperature setting. Can also be used to adjust the timer and adjust the current time.  
 
|-
 
|-
| 3
+
| 5
| - (Lower)
+
| ROOM TEMPERATURE SETTING
| Press to lower the temperature setting.
+
| Press to lower the temperature setting. Can also be used to adjust the timer and adjust the current time.  
 
|-
 
|-
| 4
+
| 6
| FAN
+
| SMART
| Press to set fan speed. Rotates between Auto and Speeds 1-4.  
+
| Adjust smart settings.  
 
|-
 
|-
| 5
+
| 7
 
| SWING
 
| SWING
| Press to set swing angle.
+
| Used to stop or start vertical adjustment louver swinging and set the desired up/down airflow direction.
 +
|-
 +
| 8
 +
| SLEEP
 +
| Used to set or cancel Sleep Mode operation.
 +
|-
 +
| 9
 +
| IFEEL
 +
| Used to set IFEEL operation.
 +
|-
 +
| 10
 +
| CLOCK
 +
| Used to set the current time.
 +
|-
 +
| 11
 +
| TIMER ON
 +
| Used to turn the timer function on.
 +
|-
 +
| 12
 +
| TIMER OFF
 +
| Used to turn the timer function off.
 
|-
 
|-
| 6
+
| 13
| SLEEP
+
| SUPER
| Press to turn on sleep function.  
+
| Used to start/stop the super cool/heat function. (Super cooling operates at high fan speed with a default 64 F temperature setting. Super heating operates at high fan speed with a default 89 F temperature setting.)
 
|-
 
|-
| 7
+
| 14
| TIMER
+
| DIMMER
| Manage the on and off timer with this button.  
+
| Pressing this button will dim the display on the indoor unit. Pressing any button will reverse the dimmer.  
 
|}
 
|}
 
== Wiring Diagram ==
 
== Wiring Diagram ==
[[File:Blue-9-12k-IDU-WD.png|none|thumb|500px|ACZEM4H4R09 Wiring Diagram]]
+
[[File:Blue2-9-12k-IDU-WDF.png|none|thumb|500px|ABSEM4H4S09 Wiring Diagram]]
 +
 
 
== PCB Printed Diagram ==  
 
== PCB Printed Diagram ==  
[[File:Blue-9-12k-IDU-PCB.png|right|thumb|500px|ACZEM4H4R09 PCB Printed Diagram]]
+
[[File:Blue2-9-12k-IDU-PCB.png|right|thumb|500px|ABSEM4H4S09 PCB Printed Diagram]]
 
{| class="wikitable"
 
{| class="wikitable"
 
! Number
 
! Number
Line 48: Line 73:
 
|-
 
|-
 
| 1
 
| 1
| Live wire interface
+
| PG Motor Interface
 
|-
 
|-
 
| 2  
 
| 2  
| Fuse
+
| Room temperature sensor
 
|-
 
|-
 
| 3  
 
| 3  
| Neutral wire interface
+
| Pipe temperature sensor
 
|-
 
|-
 
| 4  
 
| 4  
| PG motor interface
+
| Switch buton
 
|-
 
|-
 
| 5  
 
| 5  
| Communication port of neutral wire and live wire
+
| Feedback from PG Motor
 
|-
 
|-
 
| 6
 
| 6
| Auto button
+
| Up & down swing
 
|-
 
|-
 
| 7  
 
| 7  
| Up & down swing interface
+
| Left & right swing  
 
|-
 
|-
 
| 8  
 
| 8  
| PG feedback interface
+
| Wiring control or Wifi interface
 
|-
 
|-
 
| 9
 
| 9
Line 75: Line 100:
 
|-
 
|-
 
| 10  
 
| 10  
| Ambient temperature sensor
+
| Protective tube
|-
 
| 11
 
| Tube temperature sensor
 
 
|}
 
|}
 
<br />
 
<br />
 
<br />
 
<br />
<br />
+
 
<br />
 
<br />
 
<br />
 
<br />
 
<br />
 
 
== Exploded View and Parts List ==  
 
== Exploded View and Parts List ==  
[[File:Blue-9-12k-IDU-EV.png|left|thumb|500px|ACZEM4H4R09 Exploded View]]
+
[[File:Blue2-9-12k-IDU-EV.png|center|thumb|500px|ABSEM4H4S09 Exploded View]]
 
{| class="wikitable"
 
{| class="wikitable"
 
! Number
 
! Number
 
! Part Name
 
! Part Name
 +
! Part Number
 
|-
 
|-
 
| 1  
 
| 1  
| Front Panel Sub-Assy
+
| Installation Plate Assy
 +
| 1465589
 
|-
 
|-
 
| 2
 
| 2
| Filter Sub-Assy
+
| Baffle
 +
| 1465666
 
|-  
 
|-  
 
| 3  
 
| 3  
| Front Case Sub-Assy
+
| Base Holder Part
 +
| 1854439
 
|-
 
|-
 
| 4  
 
| 4  
| Guide Louver
+
| Vertical Level Vane
 +
| 1555378
 
|-
 
|-
 
| 5  
 
| 5  
| Axile Bush
+
| Center Staff
 +
| 1555381
 
|-
 
|-
 
| 6
 
| 6
| Rear Grill
+
| Center Staff
 +
| 1555385
 
|-
 
|-
 
| 7  
 
| 7  
| Air Louver 2
+
| Center Staff
 +
| 1555387
 
|-
 
|-
 
| 8  
 
| 8  
| Helicoid Tongue
+
| Step Motor
 +
| 1260259
 
|-
 
|-
 
| 9  
 
| 9  
| Left Axile Bush
+
| Motor Guard
 +
| 1465756
 
|-
 
|-
 
| 10
 
| 10
| Rear Case Assy
+
| Level Vane
 +
| 1555374
 
|-
 
|-
 
| 11
 
| 11
| Ring of Bearing
+
| Cross-Flow Fan Blade
 +
| 1466014
 
|-
 
|-
 
| 12
 
| 12
| O-Gasket Sub-Assy of Bearing  
+
| Bearing  
 +
| 1223739
 
|-
 
|-
 
| 13
 
| 13
| Cross Flow Fan
+
| Baffle
 +
| 1465670
 
|-
 
|-
 
| 14
 
| 14
| Evaporator Support
+
| Refrigeration System
 +
| 1902702
 
|-
 
|-
 
| 15
 
| 15
| Evaporator Assy
+
| Motor Guard
 +
| 1555386
 
|-
 
|-
 
| 16  
 
| 16  
| Motor Press Plate
+
| Fan Motor  
 +
| 1857574
 
|-
 
|-
 
| 17
 
| 17
| Wall Mounting Frame
+
| Motor Cover
 +
| 1465757
 
|-
 
|-
 
| 18
 
| 18
| Drainage Hose
+
| Remote Controller
 +
| 1854426
 
|-
 
|-
 
| 19
 
| 19
| Fan Motor
+
| Electric Box Cover
 +
| 1465763
 
|-
 
|-
 
| 20
 
| 20
| Connecting Pipe Clamp
+
| Temperature Sensor
 +
| 1387643
 
|-
 
|-
 
| 21  
 
| 21  
| Rubber Plug (Water Tray)
+
| Temperature Sensor
 +
| 1471151
 
|-
 
|-
 
| 22  
 
| 22  
| Cable Cross Plate
+
| Over Clamp
 +
| 1839902
 
|-
 
|-
 
| 23
 
| 23
| Stepping Motor
+
| Wire Terminal Board
 +
| 1852126
 
|-
 
|-
 
| 24
 
| 24
| Crank
+
| Electric Box Cover
 +
| 1840039
 
|-
 
|-
 
| 25
 
| 25
| Screw Cover
+
| Electric Joint Box Plate 
 +
| 1465761
 
|-
 
|-
 
| 26
 
| 26
| Air Louver 1
+
| Indoor Main Control Board Component 
 +
| 1854257
 
|-
 
|-
 
| 27
 
| 27
 
| Electric Box
 
| Electric Box
 +
| 1868909
 
|-
 
|-
 
| 28  
 
| 28  
| Magnetic Ring
+
| Electric Joint Box Plate
 +
| 1465762
 
|-
 
|-
 
| 29
 
| 29
| Terminal Board
+
| Water Pipe Parts
 +
| 1470426
 
|-
 
|-
 
| 30
 
| 30
| Electric Box Cover 2
+
| Axis Sheath
 +
| 1222824
 
|-
 
|-
 
| 31  
 
| 31  
| Main Board
+
| Step Motor
 +
| 1468408
 
|-
 
|-
 
| 32
 
| 32
| Capacitor CBB61
+
| Shell
 +
| 1816270
 
|-
 
|-
 
| 33  
 
| 33  
| Jumper
+
| Display Component
 +
| 1844146
 
|-
 
|-
 
| 34
 
| 34
| Shield Cover of Electric Box
+
| Ornamental Part
 +
| 1826489
 
|-
 
|-
 
| 35
 
| 35
| Shield Cover of Electric Box Sub-Assy
+
| Panel
|-
+
| 1819198
| 36
 
| Lower Shield Sub-Assy of Electric Box
 
|-
 
| 37
 
| Electric Box  Assy
 
|-
 
| 38
 
| Display Board
 
|-
 
| 39
 
| Ambient Temperature Sensor
 
 
|-
 
|-
| 40
+
| Unnumbered
| Remote Controller
+
| Filter Net
 +
| 1506312
 
|}
 
|}

Latest revision as of 14:45, 8 April 2022

ABSEM4H4S09 is the 22 SEER 9,000 Btu indoor unit of Blue Series 2.

Blue Series 2 evaporator (9k)

Remote Control

Remote Control
# Name Description
1 ON/OFF Press to start or stop operation.
2 MODE Press to select operation mode (Auto/Cool/Dry/Fan/Heat).
3 FAN Used to select the fan speed in sequence: auto, high, medium, or low.
4 ROOM TEMPERATURE SETTING Press to raise the temperature setting. Can also be used to adjust the timer and adjust the current time.
5 ROOM TEMPERATURE SETTING Press to lower the temperature setting. Can also be used to adjust the timer and adjust the current time.
6 SMART Adjust smart settings.
7 SWING Used to stop or start vertical adjustment louver swinging and set the desired up/down airflow direction.
8 SLEEP Used to set or cancel Sleep Mode operation.
9 IFEEL Used to set IFEEL operation.
10 CLOCK Used to set the current time.
11 TIMER ON Used to turn the timer function on.
12 TIMER OFF Used to turn the timer function off.
13 SUPER Used to start/stop the super cool/heat function. (Super cooling operates at high fan speed with a default 64 F temperature setting. Super heating operates at high fan speed with a default 89 F temperature setting.)
14 DIMMER Pressing this button will dim the display on the indoor unit. Pressing any button will reverse the dimmer.

Wiring Diagram

ABSEM4H4S09 Wiring Diagram

PCB Printed Diagram

ABSEM4H4S09 PCB Printed Diagram
Number Description
1 PG Motor Interface
2 Room temperature sensor
3 Pipe temperature sensor
4 Switch buton
5 Feedback from PG Motor
6 Up & down swing
7 Left & right swing
8 Wiring control or Wifi interface
9 Display interface
10 Protective tube



Exploded View and Parts List

ABSEM4H4S09 Exploded View
Number Part Name Part Number
1 Installation Plate Assy 1465589
2 Baffle 1465666
3 Base Holder Part 1854439
4 Vertical Level Vane 1555378
5 Center Staff 1555381
6 Center Staff 1555385
7 Center Staff 1555387
8 Step Motor 1260259
9 Motor Guard 1465756
10 Level Vane 1555374
11 Cross-Flow Fan Blade 1466014
12 Bearing 1223739
13 Baffle 1465670
14 Refrigeration System 1902702
15 Motor Guard 1555386
16 Fan Motor 1857574
17 Motor Cover 1465757
18 Remote Controller 1854426
19 Electric Box Cover 1465763
20 Temperature Sensor 1387643
21 Temperature Sensor 1471151
22 Over Clamp 1839902
23 Wire Terminal Board 1852126
24 Electric Box Cover 1840039
25 Electric Joint Box Plate 1465761
26 Indoor Main Control Board Component 1854257
27 Electric Box 1868909
28 Electric Joint Box Plate 1465762
29 Water Pipe Parts 1470426
30 Axis Sheath 1222824
31 Step Motor 1468408
32 Shell 1816270
33 Display Component 1844146
34 Ornamental Part 1826489
35 Panel 1819198
Unnumbered Filter Net 1506312