Difference between revisions of "ABSEM4H4S09"
From Technical Support Wiki
(Created page with "ABSEM4H4S09 is the 22 SEER 9,000 Btu indoor unit of ''Blue Series 2''. right|thumb|''Blue Series 2'' evaporator (9k) == Remote Control == File:RC-...") |
|||
(9 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | ABSEM4H4S09 is the 22 SEER 9,000 Btu indoor unit of ''[[Blue Series 2]]''. [[File: | + | ABSEM4H4S09 is the 22 SEER 9,000 Btu indoor unit of ''[[Blue Series 2]]''. [[File:Blue2-9-24k-evap.png|right|thumb|''Blue Series 2'' evaporator (9k)]] |
== Remote Control == | == Remote Control == | ||
− | [[File: | + | [[File:Blue-series-2-remote.png|left|thumb|200px|Remote Control]] |
{| class="wikitable" | {| class="wikitable" | ||
| # | | # | ||
Line 15: | Line 15: | ||
| Press to select operation mode (Auto/Cool/Dry/Fan/Heat). | | Press to select operation mode (Auto/Cool/Dry/Fan/Heat). | ||
|- | |- | ||
− | | 3 | + | | 3 |
− | | | + | | FAN |
− | | Press to raise the temperature setting. | + | | Used to select the fan speed in sequence: auto, high, medium, or low. |
+ | |- | ||
+ | | 4 | ||
+ | | ROOM TEMPERATURE SETTING | ||
+ | | Press to raise the temperature setting. Can also be used to adjust the timer and adjust the current time. | ||
|- | |- | ||
− | | | + | | 5 |
− | | | + | | ROOM TEMPERATURE SETTING |
− | | Press to lower the temperature setting. | + | | Press to lower the temperature setting. Can also be used to adjust the timer and adjust the current time. |
|- | |- | ||
− | | | + | | 6 |
− | | | + | | SMART |
− | | | + | | Adjust smart settings. |
|- | |- | ||
− | | | + | | 7 |
| SWING | | SWING | ||
− | | | + | | Used to stop or start vertical adjustment louver swinging and set the desired up/down airflow direction. |
+ | |- | ||
+ | | 8 | ||
+ | | SLEEP | ||
+ | | Used to set or cancel Sleep Mode operation. | ||
+ | |- | ||
+ | | 9 | ||
+ | | IFEEL | ||
+ | | Used to set IFEEL operation. | ||
+ | |- | ||
+ | | 10 | ||
+ | | CLOCK | ||
+ | | Used to set the current time. | ||
+ | |- | ||
+ | | 11 | ||
+ | | TIMER ON | ||
+ | | Used to turn the timer function on. | ||
+ | |- | ||
+ | | 12 | ||
+ | | TIMER OFF | ||
+ | | Used to turn the timer function off. | ||
|- | |- | ||
− | | | + | | 13 |
− | | | + | | SUPER |
− | | | + | | Used to start/stop the super cool/heat function. (Super cooling operates at high fan speed with a default 64 F temperature setting. Super heating operates at high fan speed with a default 89 F temperature setting.) |
|- | |- | ||
− | | | + | | 14 |
− | | | + | | DIMMER |
− | | | + | | Pressing this button will dim the display on the indoor unit. Pressing any button will reverse the dimmer. |
|} | |} | ||
== Wiring Diagram == | == Wiring Diagram == | ||
− | [[File: | + | [[File:Blue2-9-12k-IDU-WDF.png|none|thumb|500px|ABSEM4H4S09 Wiring Diagram]] |
+ | |||
== PCB Printed Diagram == | == PCB Printed Diagram == | ||
− | [[File: | + | [[File:Blue2-9-12k-IDU-PCB.png|right|thumb|500px|ABSEM4H4S09 PCB Printed Diagram]] |
{| class="wikitable" | {| class="wikitable" | ||
! Number | ! Number | ||
Line 48: | Line 73: | ||
|- | |- | ||
| 1 | | 1 | ||
− | | | + | | PG Motor Interface |
|- | |- | ||
| 2 | | 2 | ||
− | | | + | | Room temperature sensor |
|- | |- | ||
| 3 | | 3 | ||
− | | | + | | Pipe temperature sensor |
|- | |- | ||
| 4 | | 4 | ||
− | | | + | | Switch buton |
|- | |- | ||
| 5 | | 5 | ||
− | | | + | | Feedback from PG Motor |
|- | |- | ||
| 6 | | 6 | ||
− | | | + | | Up & down swing |
|- | |- | ||
| 7 | | 7 | ||
− | | | + | | Left & right swing |
|- | |- | ||
| 8 | | 8 | ||
− | | | + | | Wiring control or Wifi interface |
|- | |- | ||
| 9 | | 9 | ||
Line 75: | Line 100: | ||
|- | |- | ||
| 10 | | 10 | ||
− | | | + | | Protective tube |
− | |||
− | |||
− | |||
|} | |} | ||
<br /> | <br /> | ||
<br /> | <br /> | ||
− | + | ||
− | |||
− | |||
− | |||
− | |||
− | |||
== Exploded View and Parts List == | == Exploded View and Parts List == | ||
− | [[File: | + | [[File:Blue2-9-12k-IDU-EV.png|center|thumb|500px|ABSEM4H4S09 Exploded View]] |
{| class="wikitable" | {| class="wikitable" | ||
! Number | ! Number | ||
! Part Name | ! Part Name | ||
+ | ! Part Number | ||
|- | |- | ||
| 1 | | 1 | ||
− | | | + | | Installation Plate Assy |
+ | | 1465589 | ||
|- | |- | ||
| 2 | | 2 | ||
− | | | + | | Baffle |
+ | | 1465666 | ||
|- | |- | ||
| 3 | | 3 | ||
− | | | + | | Base Holder Part |
+ | | 1854439 | ||
|- | |- | ||
| 4 | | 4 | ||
− | | | + | | Vertical Level Vane |
+ | | 1555378 | ||
|- | |- | ||
| 5 | | 5 | ||
− | | | + | | Center Staff |
+ | | 1555381 | ||
|- | |- | ||
| 6 | | 6 | ||
− | | | + | | Center Staff |
+ | | 1555385 | ||
|- | |- | ||
| 7 | | 7 | ||
− | | | + | | Center Staff |
+ | | 1555387 | ||
|- | |- | ||
| 8 | | 8 | ||
− | | | + | | Step Motor |
+ | | 1260259 | ||
|- | |- | ||
| 9 | | 9 | ||
− | | | + | | Motor Guard |
+ | | 1465756 | ||
|- | |- | ||
| 10 | | 10 | ||
− | | | + | | Level Vane |
+ | | 1555374 | ||
|- | |- | ||
| 11 | | 11 | ||
− | | | + | | Cross-Flow Fan Blade |
+ | | 1466014 | ||
|- | |- | ||
| 12 | | 12 | ||
− | | | + | | Bearing |
+ | | 1223739 | ||
|- | |- | ||
| 13 | | 13 | ||
− | | | + | | Baffle |
+ | | 1465670 | ||
|- | |- | ||
| 14 | | 14 | ||
− | | | + | | Refrigeration System |
+ | | 1902702 | ||
|- | |- | ||
| 15 | | 15 | ||
− | | | + | | Motor Guard |
+ | | 1555386 | ||
|- | |- | ||
| 16 | | 16 | ||
− | | Motor | + | | Fan Motor |
+ | | 1857574 | ||
|- | |- | ||
| 17 | | 17 | ||
− | | | + | | Motor Cover |
+ | | 1465757 | ||
|- | |- | ||
| 18 | | 18 | ||
− | | | + | | Remote Controller |
+ | | 1854426 | ||
|- | |- | ||
| 19 | | 19 | ||
− | | | + | | Electric Box Cover |
+ | | 1465763 | ||
|- | |- | ||
| 20 | | 20 | ||
− | | | + | | Temperature Sensor |
+ | | 1387643 | ||
|- | |- | ||
| 21 | | 21 | ||
− | | | + | | Temperature Sensor |
+ | | 1471151 | ||
|- | |- | ||
| 22 | | 22 | ||
− | | | + | | Over Clamp |
+ | | 1839902 | ||
|- | |- | ||
| 23 | | 23 | ||
− | | | + | | Wire Terminal Board |
+ | | 1852126 | ||
|- | |- | ||
| 24 | | 24 | ||
− | | | + | | Electric Box Cover |
+ | | 1840039 | ||
|- | |- | ||
| 25 | | 25 | ||
− | | | + | | Electric Joint Box Plate |
+ | | 1465761 | ||
|- | |- | ||
| 26 | | 26 | ||
− | | | + | | Indoor Main Control Board Component |
+ | | 1854257 | ||
|- | |- | ||
| 27 | | 27 | ||
| Electric Box | | Electric Box | ||
+ | | 1868909 | ||
|- | |- | ||
| 28 | | 28 | ||
− | | | + | | Electric Joint Box Plate |
+ | | 1465762 | ||
|- | |- | ||
| 29 | | 29 | ||
− | | | + | | Water Pipe Parts |
+ | | 1470426 | ||
|- | |- | ||
| 30 | | 30 | ||
− | | | + | | Axis Sheath |
+ | | 1222824 | ||
|- | |- | ||
| 31 | | 31 | ||
− | | | + | | Step Motor |
+ | | 1468408 | ||
|- | |- | ||
| 32 | | 32 | ||
− | | | + | | Shell |
+ | | 1816270 | ||
|- | |- | ||
| 33 | | 33 | ||
− | | | + | | Display Component |
+ | | 1844146 | ||
|- | |- | ||
| 34 | | 34 | ||
− | | | + | | Ornamental Part |
+ | | 1826489 | ||
|- | |- | ||
| 35 | | 35 | ||
− | | | + | | Panel |
− | | | + | | 1819198 |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | Unnumbered |
− | | | + | | Filter Net |
+ | | 1506312 | ||
|} | |} |
Latest revision as of 14:45, 8 April 2022
ABSEM4H4S09 is the 22 SEER 9,000 Btu indoor unit of Blue Series 2.
Remote Control
# | Name | Description |
1 | ON/OFF | Press to start or stop operation. |
2 | MODE | Press to select operation mode (Auto/Cool/Dry/Fan/Heat). |
3 | FAN | Used to select the fan speed in sequence: auto, high, medium, or low. |
4 | ROOM TEMPERATURE SETTING | Press to raise the temperature setting. Can also be used to adjust the timer and adjust the current time. |
5 | ROOM TEMPERATURE SETTING | Press to lower the temperature setting. Can also be used to adjust the timer and adjust the current time. |
6 | SMART | Adjust smart settings. |
7 | SWING | Used to stop or start vertical adjustment louver swinging and set the desired up/down airflow direction. |
8 | SLEEP | Used to set or cancel Sleep Mode operation. |
9 | IFEEL | Used to set IFEEL operation. |
10 | CLOCK | Used to set the current time. |
11 | TIMER ON | Used to turn the timer function on. |
12 | TIMER OFF | Used to turn the timer function off. |
13 | SUPER | Used to start/stop the super cool/heat function. (Super cooling operates at high fan speed with a default 64 F temperature setting. Super heating operates at high fan speed with a default 89 F temperature setting.) |
14 | DIMMER | Pressing this button will dim the display on the indoor unit. Pressing any button will reverse the dimmer. |
Wiring Diagram
PCB Printed Diagram
Number | Description |
---|---|
1 | PG Motor Interface |
2 | Room temperature sensor |
3 | Pipe temperature sensor |
4 | Switch buton |
5 | Feedback from PG Motor |
6 | Up & down swing |
7 | Left & right swing |
8 | Wiring control or Wifi interface |
9 | Display interface |
10 | Protective tube |
Exploded View and Parts List
Number | Part Name | Part Number |
---|---|---|
1 | Installation Plate Assy | 1465589 |
2 | Baffle | 1465666 |
3 | Base Holder Part | 1854439 |
4 | Vertical Level Vane | 1555378 |
5 | Center Staff | 1555381 |
6 | Center Staff | 1555385 |
7 | Center Staff | 1555387 |
8 | Step Motor | 1260259 |
9 | Motor Guard | 1465756 |
10 | Level Vane | 1555374 |
11 | Cross-Flow Fan Blade | 1466014 |
12 | Bearing | 1223739 |
13 | Baffle | 1465670 |
14 | Refrigeration System | 1902702 |
15 | Motor Guard | 1555386 |
16 | Fan Motor | 1857574 |
17 | Motor Cover | 1465757 |
18 | Remote Controller | 1854426 |
19 | Electric Box Cover | 1465763 |
20 | Temperature Sensor | 1387643 |
21 | Temperature Sensor | 1471151 |
22 | Over Clamp | 1839902 |
23 | Wire Terminal Board | 1852126 |
24 | Electric Box Cover | 1840039 |
25 | Electric Joint Box Plate | 1465761 |
26 | Indoor Main Control Board Component | 1854257 |
27 | Electric Box | 1868909 |
28 | Electric Joint Box Plate | 1465762 |
29 | Water Pipe Parts | 1470426 |
30 | Axis Sheath | 1222824 |
31 | Step Motor | 1468408 |
32 | Shell | 1816270 |
33 | Display Component | 1844146 |
34 | Ornamental Part | 1826489 |
35 | Panel | 1819198 |
Unnumbered | Filter Net | 1506312 |