Difference between revisions of "ASKEL4H4R18"

From Technical Support Wiki
Jump to: navigation, search
 
(One intermediate revision by the same user not shown)
Line 68: Line 68:
 
|}
 
|}
 
== Wiring Diagram ==
 
== Wiring Diagram ==
[[File:Blue-9-12k-IDU-WD.png|none|thumb|500px|ACZEM4H4R09 Wiring Diagram]]
+
[[File:SSM-FCIDU-WD.png|none|thumb|500px|ASKEL4H4R18 Wiring Diagram]]
== PCB Printed Diagram ==
 
[[File:Blue-9-12k-IDU-PCB.png|right|thumb|500px|ACZEM4H4R09 PCB Printed Diagram]]
 
{| class="wikitable"
 
! Number
 
! Description
 
|-
 
| 1
 
| Live wire interface
 
|-
 
| 2
 
| Fuse
 
|-
 
| 3
 
| Neutral wire interface
 
|-
 
| 4
 
| PG motor interface
 
|-
 
| 5
 
| Communication port of neutral wire and live wire
 
|-
 
| 6
 
| Auto button
 
|-
 
| 7
 
| Up & down swing interface
 
|-
 
| 8
 
| PG feedback interface
 
|-
 
| 9
 
| Display interface
 
|-
 
| 10
 
| Ambient temperature sensor
 
|-
 
| 11
 
| Tube temperature sensor
 
|}
 
<br />
 
<br />
 
<br />
 
<br />
 
<br />
 
<br />
 
<br />
 
<br />
 
 
== Exploded View and Parts List ==  
 
== Exploded View and Parts List ==  
[[File:Blue-9-12k-IDU-EV.png|left|thumb|500px|ACZEM4H4R09 Exploded View]]
+
[[File:SSM-18KFCIDU-EV.png|left|thumb|500px|ASKEL4H4R18 Exploded View]]
 
{| class="wikitable"
 
{| class="wikitable"
 
! Number
 
! Number
Line 123: Line 76:
 
|-
 
|-
 
| 1  
 
| 1  
| Front Panel Sub-Assy
+
| Temperature Sensor
 
|-
 
|-
 
| 2
 
| 2
| Filter Sub-Assy
+
| Room Sensor
 
|-  
 
|-  
 
| 3  
 
| 3  
| Front Case Sub-Assy
+
| Connection Board
 
|-
 
|-
 
| 4  
 
| 4  
| Guide Louver
+
| Right Cover Plate
 
|-
 
|-
 
| 5  
 
| 5  
| Axile Bush
+
| Plate Board of Water Releasing Flume
 
|-
 
|-
 
| 6
 
| 6
| Rear Grill
+
| Installation Supporting Frame
 
|-
 
|-
 
| 7  
 
| 7  
| Air Louver 2
+
| Axile Bush
 
|-
 
|-
 
| 8  
 
| 8  
| Helicoid Tongue
+
| Right Side Plate Sub-Assy
 
|-
 
|-
 
| 9  
 
| 9  
| Left Axile Bush
+
| Water Releasing Flume
 
|-
 
|-
 
| 10
 
| 10
| Rear Case Assy
+
| Connected Board (Evaporator)
 
|-
 
|-
 
| 11
 
| 11
| Ring of Bearing
+
| Air Louver
 
|-
 
|-
 
| 12
 
| 12
| O-Gasket Sub-Assy of Bearing
+
| Guide Louver Supporter Sub-Assy
 
|-
 
|-
 
| 13
 
| 13
| Cross Flow Fan
+
| Rotating Shaft
 
|-
 
|-
 
| 14
 
| 14
| Evaporator Support
+
| Front Connection Board
 
|-
 
|-
 
| 15
 
| 15
| Evaporator Assy
+
| Guide Louver
 
|-
 
|-
 
| 16  
 
| 16  
| Motor Press Plate
+
| Supporter 
 
|-
 
|-
 
| 17
 
| 17
| Wall Mounting Frame
+
| Fixed Mount
 
|-
 
|-
 
| 18
 
| 18
| Drainage Hose
+
| Display Board
 
|-
 
|-
 
| 19
 
| 19
| Fan Motor
+
| Evaporator Assy
 
|-
 
|-
 
| 20
 
| 20
| Connecting Pipe Clamp
+
| Rear Side Plate Assy
 
|-
 
|-
 
| 21  
 
| 21  
| Rubber Plug (Water Tray)
+
| Rotating Shaft
 
|-
 
|-
 
| 22  
 
| 22  
| Cable Cross Plate
+
| Connecting Rod
 
|-
 
|-
 
| 23
 
| 23
| Stepping Motor
+
| Rotating Shaft
 
|-
 
|-
 
| 24
 
| 24
| Crank
+
| Stepping Motor
 
|-
 
|-
 
| 25
 
| 25
| Screw Cover
+
| Installation Supporting Frame
 
|-
 
|-
 
| 26
 
| 26
| Air Louver 1
+
| Left Side Plate Sub-Assy
 
|-
 
|-
 
| 27
 
| 27
| Electric Box
+
| Electric Box Assy
 
|-
 
|-
 
| 28  
 
| 28  
| Magnetic Ring
+
| Main Board
 
|-
 
|-
 
| 29
 
| 29
| Terminal Board
+
| Left Cover Plate
 
|-
 
|-
 
| 30
 
| 30
| Electric Box Cover 2
+
| Terminal Board
 
|-
 
|-
 
| 31  
 
| 31  
| Main Board
+
| Terminal Board  
 
|-
 
|-
 
| 32
 
| 32
| Capacitor CBB61
+
| Remote Controller
 
|-
 
|-
 
| 33  
 
| 33  
| Jumper
+
| Mid-Clapboard Sub-Assy
 
|-
 
|-
 
| 34
 
| 34
| Shield Cover of Electric Box
+
| Support of Motor Bearing
 
|-
 
|-
 
| 35
 
| 35
| Shield Cover of Electric Box Sub-Assy
+
| O-Gasket of Bearing
 
|-
 
|-
 
| 36
 
| 36
| Lower Shield Sub-Assy of Electric Box
+
| Rotary Axis Sub-Assy
 
|-
 
|-
 
| 37
 
| 37
| Electric Box  Assy
+
| Centrifugal Fan
 
|-
 
|-
 
| 38
 
| 38
| Display Board
+
| Joint Stack
 
|-
 
|-
 
| 39  
 
| 39  
| Ambient Temperature Sensor
+
| Supporter
 
|-
 
|-
 
| 40
 
| 40
| Remote Controller
+
| Bar Clasp Sub-Assy
 +
|-
 +
| 41
 +
| Fan Motor
 +
|-
 +
| 42
 +
| Supporter
 +
|-
 +
| 43
 +
| Rear Connection Board
 +
|-
 +
| 44
 +
| Front Volute Casing
 +
|-
 +
| 45
 +
| Rear Volute Casing
 +
|-
 +
| 46
 +
| Water Tray Assy
 +
|-
 +
| 47
 +
| Top Cover Board Sub-Assy
 +
|-
 +
| 48
 +
| Front Grill Sub-Assy
 +
|-
 +
| 49
 +
| Drainage Pipe Sub-Assy
 
|}
 
|}

Latest revision as of 13:19, 17 June 2015

ASKEL4H4R18 is the 17 SEER 18,000 Btu Floor & Ceiling indoor unit of the Sky Split Series.

Sky Split Series Floor & Ceiling evaporator (18k)

Remote Control

Remote Control
# Name Description
1 Signal Transmitter Signal Transmitter
2 ON/OFF Button Press this button and the unit will be turned on; press it once more and the unit will be turned off. When turning off the unit, the Sleep function will be canceled, but the presetting time is still remained.
3 MODE Button By pressing this button, Auto, Cool, Dry, Fan, Heat mode can be selected circularly. Auto mode is default after power on. Under the Auto mode, the setting temperature will not be displayed; Under the Heat mode, the initial value is 28°C (82°F); under other modes, the initial value is 25°C (77°F).
4 + (Raise) Button Preset temperature can be increased by pressing this button. Pressing and holding this button for more than 2 seconds can make the temperature changed quickly until release this button and then transmit this order. The temperature adjustment is unavailable under the Auto mode, but the order can be sent by pressing this button. Centigrade setting range: 16~30; Fahrenheit scale setting range 61~86.
4 - (Lower) Button Preset temperature can be decreased by pressing this button. Pressing and holding this button for more than 2 seconds can make the temperature changed quickly until release this button and then transmit this order. The temperature adjustment is unavailable under the Auto mode, but the order can be sent by pressing this button. Centigrade setting range: 16~30; Fahrenheit scale setting range 61~86.
5 FAN Button By pressing this button, Auto, Low, Middle, High speed can be circularly selected. After power on, Auto fan speed is default.
6 SWING UP/DOWN Button Press this button to set up the swing angle.
7 CLOCK Button By pressing this button, the clock is allowed to be set, with the clock symbol blinking, and then press the +/- button to adjust the clock within 5 seconds. If the +/-button is pressed down constantly for more than 2 seconds, the clock setting will be increased or decreased 10 minutes every 0.5 seconds. After that, another press on the CLOCK button accepts the setting. 12:00 is the default, when the wireless remote controller is energized.
8 TIMER ON Button When TIMER ON is activated, ON will blink while the clock symbol will disappear. Within 5 seconds it is allowed to set the ON time by pressing the +/- button. Each press will make the time increase or decrease one minute. Besides, the time can also be set by pressing the +/- button constantly. That is, in the early 2.5 seconds, the time will increase/decrease quickly per single minute, and in the late 2.5, the time will increase/decrease per ten minutes. After the desired time value is set, press TIENE ON again to conform the setting within five seconds. After that, another press on TIMER ON will cancel the setting. Prior to this setting, the clock shall be set to the actual time.
9 X-FAN Button Pressing this button can activate or deactivate the X-FAN function. In Cool or Dry mode, by pressing this button, if the fan symbol is displayed, it indicates the X-FAN function is activated. By repressing this button, if the fan symbol disappears, it indicates the X-FAN function is deactivated. After energizing, X-FAN OFF is defaulted. If the unit is turned off, X-FAN can be deactivated but can't be activated.
10 TEMP Button By pressing this button you can display the indoor setting temperature or the indoor ambient temperature.
11 TIMER OFF Button This turns the TIMER function off.
12 TURBO Button In Cool or Heat mode, pressing this button can activate or deactivate the TURBO function. When the TURBO function is activated, its symbol (a whirling fan) will be displayed; when the running mode or the fan speed is changed, this function will be canceled automatically.
13 SLEEP Button By pressing this button, Sleep On and Sleep Off can be selected. When Sleep is set to On, the crescent moon symbol will display. Under the Fan and Auto modes, this function is not available.
14 LIGHT Button Pressing this button will illuminate the buttons on the remote control, enabling usage during darkness. The lightbulb symbol will appear on the the remote's display.

Wiring Diagram

ASKEL4H4R18 Wiring Diagram

Exploded View and Parts List

ASKEL4H4R18 Exploded View
Number Part Name
1 Temperature Sensor
2 Room Sensor
3 Connection Board
4 Right Cover Plate
5 Plate Board of Water Releasing Flume
6 Installation Supporting Frame
7 Axile Bush
8 Right Side Plate Sub-Assy
9 Water Releasing Flume
10 Connected Board (Evaporator)
11 Air Louver
12 Guide Louver Supporter Sub-Assy
13 Rotating Shaft
14 Front Connection Board
15 Guide Louver
16 Supporter
17 Fixed Mount
18 Display Board
19 Evaporator Assy
20 Rear Side Plate Assy
21 Rotating Shaft
22 Connecting Rod
23 Rotating Shaft
24 Stepping Motor
25 Installation Supporting Frame
26 Left Side Plate Sub-Assy
27 Electric Box Assy
28 Main Board
29 Left Cover Plate
30 Terminal Board
31 Terminal Board
32 Remote Controller
33 Mid-Clapboard Sub-Assy
34 Support of Motor Bearing
35 O-Gasket of Bearing
36 Rotary Axis Sub-Assy
37 Centrifugal Fan
38 Joint Stack
39 Supporter
40 Bar Clasp Sub-Assy
41 Fan Motor
42 Supporter
43 Rear Connection Board
44 Front Volute Casing
45 Rear Volute Casing
46 Water Tray Assy
47 Top Cover Board Sub-Assy
48 Front Grill Sub-Assy