Difference between revisions of "ACZCH4H4R18"
From Technical Support Wiki
(Created page with "ACZCI4H4R12 is the 15 SEER 12,000 Btu outdoor unit of the ''Blue Series''. right|thumb|''Blue Series'' condenser (18k) == Wiring Diagram == File...") |
|||
| (4 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
| − | + | ACZCI4H4R18 is the 15 SEER 18,000 Btu outdoor unit of the ''[[Blue Series]]''. [[File:Plat-cond-2.png|right|thumb|''Blue Series'' condenser (18k)]] | |
== Wiring Diagram == | == Wiring Diagram == | ||
[[File:Blue-18k-ODU-WD.png|none|thumb|500px|ACZCI4H4R18 Wiring Diagram]] | [[File:Blue-18k-ODU-WD.png|none|thumb|500px|ACZCI4H4R18 Wiring Diagram]] | ||
== PCB Printed Diagram == | == PCB Printed Diagram == | ||
| − | [[File:Blue-18-24K-ODU-PCB.png|right|thumb|500px| | + | [[File:Blue-18-24K-ODU-PCB.png|right|thumb|500px|ACZCI4H4R18 PCB Diagram]] |
{| class="wikitable" | {| class="wikitable" | ||
! Number | ! Number | ||
| Line 47: | Line 47: | ||
| PFC inductance wire | | PFC inductance wire | ||
|} | |} | ||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
<br /> | <br /> | ||
<br /> | <br /> | ||
| Line 60: | Line 53: | ||
<br /> | <br /> | ||
== Exploded View and Parts List == | == Exploded View and Parts List == | ||
| − | [[File:Blue- | + | [[File:Blue-18k-ODU-EV.png|left|thumb|500px|ACZCI4H4R18 Exploded View]] |
{| class="wikitable" | {| class="wikitable" | ||
! Number | ! Number | ||
| Line 72: | Line 65: | ||
|- | |- | ||
| 3 | | 3 | ||
| − | | Axial Flow Fan | + | | Axial Flow Fan |
|- | |- | ||
| 4 | | 4 | ||
| Line 78: | Line 71: | ||
|- | |- | ||
| 5 | | 5 | ||
| − | | | + | | Chassis Sub-Assy |
|- | |- | ||
| 6 | | 6 | ||
| − | | | + | | Drainage hole Cap |
|- | |- | ||
| 7 | | 7 | ||
| − | | Clapboard | + | | Clapboard Assy |
|- | |- | ||
| 8 | | 8 | ||
| − | | | + | | Gas-liquid Separator |
|- | |- | ||
| 9 | | 9 | ||
| − | | | + | | 4-Way Valve Assy |
|- | |- | ||
| 10 | | 10 | ||
| − | | | + | | Compressor and Fittings |
|- | |- | ||
| 11 | | 11 | ||
| − | | | + | | Valve Support Assy |
|- | |- | ||
| 12 | | 12 | ||
| − | | | + | | Cut off Valve Assy 1/2 |
|- | |- | ||
| 13 | | 13 | ||
| − | | | + | | Cut off Valve Sub-Assy |
|- | |- | ||
| 14 | | 14 | ||
| − | | | + | | Right Side Plate |
|- | |- | ||
| 15 | | 15 | ||
| − | | | + | | Valve Cover |
|- | |- | ||
| 16 | | 16 | ||
| − | | | + | | Retaining Plate |
|- | |- | ||
| 17 | | 17 | ||
| − | | | + | | Handle Assy |
|- | |- | ||
| 18 | | 18 | ||
| − | | | + | | Wiring Clamp |
|- | |- | ||
| 19 | | 19 | ||
| − | | | + | | Temperature Sensor |
|- | |- | ||
| 20 | | 20 | ||
| − | | | + | | Rear Grill |
|- | |- | ||
| 21 | | 21 | ||
| − | | | + | | Condenser Assy |
|- | |- | ||
| 22 | | 22 | ||
| − | | | + | | Reactor |
|- | |- | ||
| 23 | | 23 | ||
| − | | | + | | Coping |
|- | |- | ||
| 24 | | 24 | ||
| + | | Motor Support Sub-Assy | ||
| + | |- | ||
| + | | 25 | ||
| + | | Condenser Support Plate | ||
| + | |- | ||
| + | | 26 | ||
| + | | Left Side Plate | ||
| + | |- | ||
| + | | 27 | ||
| + | | Left Handle | ||
| + | |- | ||
| + | | 28 | ||
| Electric Box Assy | | Electric Box Assy | ||
| + | |- | ||
| + | | 29 | ||
| + | | Terminal Board | ||
| + | |- | ||
| + | | 30 | ||
| + | | Electric Box | ||
| + | |- | ||
| + | | 31 | ||
| + | | Main Board | ||
| + | |- | ||
| + | | 32 | ||
| + | | Radiator | ||
|} | |} | ||
== Piping Sizes == | == Piping Sizes == | ||
| Line 143: | Line 160: | ||
|- | |- | ||
| 1/4" | | 1/4" | ||
| − | | | + | | 1/2" |
|} | |} | ||
== Accessories == | == Accessories == | ||
*[[Wall Bracket (QBR-19.5)]] | *[[Wall Bracket (QBR-19.5)]] | ||
*[[Universal Remote (QTH-4000)]] | *[[Universal Remote (QTH-4000)]] | ||
Latest revision as of 18:07, 29 April 2014
ACZCI4H4R18 is the 15 SEER 18,000 Btu outdoor unit of the Blue Series.
Wiring Diagram
File:Blue-18k-ODU-WD.png
ACZCI4H4R18 Wiring Diagram
PCB Printed Diagram
| Number | Description |
|---|---|
| 1 | Compressor wiring connection terminal |
| 2 | ODU heat exchanger middle copper pipe temp sensor terminal |
| 3 | Compressor overload protection terminal |
| 4 | ODU temp sensor terminal |
| 5 | EXV terminal |
| 6 | Outdoor fan terminal |
| 7 | Four-way valve terminal |
| 8 | Chasis electric heating wiring terminal |
| 9 | Communication cable with IDU |
| 10 | Power supply live wire |
| 11 | Ground wire |
| 12 | Power supply neutral wire |
| 13 | PFC inductance wire |
Exploded View and Parts List
| Number | Part Name |
|---|---|
| 1 | Front Grill |
| 2 | Cabinet |
| 3 | Axial Flow Fan |
| 4 | Fan Motor |
| 5 | Chassis Sub-Assy |
| 6 | Drainage hole Cap |
| 7 | Clapboard Assy |
| 8 | Gas-liquid Separator |
| 9 | 4-Way Valve Assy |
| 10 | Compressor and Fittings |
| 11 | Valve Support Assy |
| 12 | Cut off Valve Assy 1/2 |
| 13 | Cut off Valve Sub-Assy |
| 14 | Right Side Plate |
| 15 | Valve Cover |
| 16 | Retaining Plate |
| 17 | Handle Assy |
| 18 | Wiring Clamp |
| 19 | Temperature Sensor |
| 20 | Rear Grill |
| 21 | Condenser Assy |
| 22 | Reactor |
| 23 | Coping |
| 24 | Motor Support Sub-Assy |
| 25 | Condenser Support Plate |
| 26 | Left Side Plate |
| 27 | Left Handle |
| 28 | Electric Box Assy |
| 29 | Terminal Board |
| 30 | Electric Box |
| 31 | Main Board |
| 32 | Radiator |
Piping Sizes
| Liquid Side | Gas Side |
|---|---|
| 1/4" | 1/2" |