Difference between revisions of "A13EM4H4G18"

From Technical Support Wiki
Jump to: navigation, search
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
A13CH4H4G18 is the 13 SEER 18,000 Btu mini split in the ''[[Bronze Series]]'' line. [[File:Bronze-evaporator.png|right|thumb|''Bronze Series'' evaporator (18k)]]
 
A13CH4H4G18 is the 13 SEER 18,000 Btu mini split in the ''[[Bronze Series]]'' line. [[File:Bronze-evaporator.png|right|thumb|''Bronze Series'' evaporator (18k)]]
 
== Remote Control ==  
 
== Remote Control ==  
 +
[[File:Bronze-Remote.jpg|left|thumb|200px|Remote Control]]
 +
{| class="wikitable"
 +
! Button Name
 +
! Description
 +
|-
 +
| OPERATION MODE Indicator
 +
| Indicates selected operation mode.
 +
|-
 +
| FAN SPEED Indicator
 +
| Indicates the selected Air Rate.
 +
|-
 +
| TIME Indicator
 +
| During TIMER operation indicates the timer. During normal operation, it indicates the time.
 +
|-
 +
| SET TEMPERATURE 
 +
| This button sets the room temperature.
 +
|-
 +
| SLEEP
 +
| This button changes to SLEEP operation.
 +
|-
 +
| AUTOSTART
 +
| This button is used for timing the AUTOSTART function.
 +
|-
 +
| AUTOSTOP
 +
| This button is used for timing the AUTOSTOP function
 +
|-
 +
| TEMPERATURE Indicator
 +
| Indicates the set temperature.
 +
|-
 +
| AIR FLOW Indicator
 +
| Indicates the selected flap mode.
 +
|-
 +
| ON/OFF
 +
| Controls the powered state of the mini split.
 +
|-
 +
| VANE CONTROL
 +
| This button changes the flap mode.
 +
|-
 +
|  MODE
 +
| This button, whenever pressed, changes the operation mode in the following order: Auto->Cool->Dry->Heat->Fan.
 +
|-
 +
| FAN SPEED
 +
| This button sets the air rate.
 +
|-
 +
| SWING
 +
| This button adjusts the air swinging direction.
 +
|-
 +
| TIME SET
 +
| These two buttons are used for setting the time as well as autostart and stop times.
 +
|}
 +
== Exploded View and Parts List ==
 +
[[File:Bronze-18k-24k-IDU-EV.jpg|thumb|500px|A13EM4H4G18 Exploded View]]
 +
{| class="wikitable"
 +
! Number
 +
! Part Name
 +
|-
 +
| 1
 +
| Wall-Mounting Frame
 +
|-
 +
| 2
 +
| Base
 +
|-
 +
| 3
 +
| Cross Flow Fan
 +
|-
 +
| 4
 +
| Cross Flow Fan Bearing
 +
|-
 +
| 5
 +
| Ring of Cross Flow Fan Bearing
 +
|-
 +
| 6
 +
| Room Temp Sonde Frame
 +
|-
 +
| 7
 +
| Evaporator Assembly
 +
|-
 +
| 8
 +
| Evaporator Fixed Plate
 +
|-
 +
| 9
 +
| Electric Heater
 +
|-
 +
| 10
 +
| Outlet Part
 +
|-
 +
| 11
 +
| Louver A
 +
|-
 +
| 12
 +
| Louver B
 +
|-
 +
| 14
 +
| Bearing D
 +
|-
 +
| 16
 +
| Swing Louver (Little)
 +
|-
 +
| 19
 +
| Louvers
 +
|-
 +
| 20
 +
| Supply Grill
 +
|-
 +
| 21
 +
| Middle Frame
 +
|-
 +
| 22
 +
| Screw Cover
 +
|-
 +
| 23
 +
| Cold Catalyst
 +
|-
 +
| 24
 +
| Left Air Filter
 +
|-
 +
| 25
 +
| Right Air Filter
 +
|-
 +
| 26
 +
| Front Panel
 +
|-
 +
| 27
 +
| Line and Drain Cover
 +
|-
 +
| 28
 +
| Blower Motor Cover
 +
|-
 +
| 29
 +
| Motor
 +
|-
 +
| 30
 +
| Motor Clamp
 +
|-
 +
| 31
 +
| Electric Box
 +
|-
 +
| 32
 +
| Electric Box Bottom Cover
 +
|-
 +
| 33
 +
| Electric Box Front Cover
 +
|-
 +
| 35
 +
| Board Base
 +
|-
 +
| 36
 +
| Display Lamp Frame
 +
|-
 +
| 37
 +
| Room Temp Sensor
 +
|-
 +
| 38
 +
| Tube Temp Sensor
 +
|-
 +
| 39
 +
| Sensor Cover
 +
|-
 +
| 40
 +
| Power Wire
 +
|-
 +
| 41
 +
| Terminal Board
 +
|-
 +
| 42
 +
| Connecting Cable
 +
|-
 +
| 43
 +
| Thermal Insulation Pipe
 +
|-
 +
| 52
 +
| Step Motor
 +
|-
 +
| 53
 +
| Bearing A
 +
|-
 +
| 54
 +
| Bearing B
 +
|-
 +
| 55
 +
| Wire Clip
 +
|-
 +
| 56
 +
| Water-Resistant Board
 +
|-
 +
| 58
 +
| Bearing C
 +
|-
 +
| 59
 +
| Step Motor
 +
|-
 +
| 61
 +
| Display Box
 +
|-
 +
| 62
 +
| Display Lamp Panel
 +
|-
 +
| 63
 +
| Remote Controller
 +
|}
 
== Board ==
 
== Board ==

Latest revision as of 20:34, 17 December 2013

A13CH4H4G18 is the 13 SEER 18,000 Btu mini split in the Bronze Series line.

Bronze Series evaporator (18k)

Remote Control

Remote Control
Button Name Description
OPERATION MODE Indicator Indicates selected operation mode.
FAN SPEED Indicator Indicates the selected Air Rate.
TIME Indicator During TIMER operation indicates the timer. During normal operation, it indicates the time.
SET TEMPERATURE This button sets the room temperature.
SLEEP This button changes to SLEEP operation.
AUTOSTART This button is used for timing the AUTOSTART function.
AUTOSTOP This button is used for timing the AUTOSTOP function
TEMPERATURE Indicator Indicates the set temperature.
AIR FLOW Indicator Indicates the selected flap mode.
ON/OFF Controls the powered state of the mini split.
VANE CONTROL This button changes the flap mode.
MODE This button, whenever pressed, changes the operation mode in the following order: Auto->Cool->Dry->Heat->Fan.
FAN SPEED This button sets the air rate.
SWING This button adjusts the air swinging direction.
TIME SET These two buttons are used for setting the time as well as autostart and stop times.

Exploded View and Parts List

A13EM4H4G18 Exploded View
Number Part Name
1 Wall-Mounting Frame
2 Base
3 Cross Flow Fan
4 Cross Flow Fan Bearing
5 Ring of Cross Flow Fan Bearing
6 Room Temp Sonde Frame
7 Evaporator Assembly
8 Evaporator Fixed Plate
9 Electric Heater
10 Outlet Part
11 Louver A
12 Louver B
14 Bearing D
16 Swing Louver (Little)
19 Louvers
20 Supply Grill
21 Middle Frame
22 Screw Cover
23 Cold Catalyst
24 Left Air Filter
25 Right Air Filter
26 Front Panel
27 Line and Drain Cover
28 Blower Motor Cover
29 Motor
30 Motor Clamp
31 Electric Box
32 Electric Box Bottom Cover
33 Electric Box Front Cover
35 Board Base
36 Display Lamp Frame
37 Room Temp Sensor
38 Tube Temp Sensor
39 Sensor Cover
40 Power Wire
41 Terminal Board
42 Connecting Cable
43 Thermal Insulation Pipe
52 Step Motor
53 Bearing A
54 Bearing B
55 Wire Clip
56 Water-Resistant Board
58 Bearing C
59 Step Motor
61 Display Box
62 Display Lamp Panel
63 Remote Controller

Board