Difference between revisions of "AMSCI4H4S24"
From Technical Support Wiki
| (2 intermediate revisions by the same user not shown) | |||
| Line 3: | Line 3: | ||
== Wiring Diagram == | == Wiring Diagram == | ||
[[File:MP-ODU-24K-WD.png|none|thumb|500px|AMSCI4H4S24 Wiring Diagram]] | [[File:MP-ODU-24K-WD.png|none|thumb|500px|AMSCI4H4S24 Wiring Diagram]] | ||
| − | |||
| − | |||
| − | |||
== Exploded View and Parts List == | == Exploded View and Parts List == | ||
| Line 12: | Line 9: | ||
! Number | ! Number | ||
! Part Description | ! Part Description | ||
| + | |- | ||
| + | | 1 | ||
| + | | Fan Guard | ||
| + | |- | ||
| + | | 2 | ||
| + | | Front Panel | ||
| + | |- | ||
| + | | 3 | ||
| + | | Left Guard Filter | ||
| + | |- | ||
| + | | 4 | ||
| + | | Mounting Plate | ||
| + | |- | ||
| + | | 5 | ||
| + | | Welding Hex Nuts | ||
| + | |- | ||
| + | | 6 | ||
| + | | Propeller Fan | ||
| + | |- | ||
| + | | 7 | ||
| + | | Fan Motor | ||
| + | |- | ||
| + | | 8 | ||
| + | | Motor Bracket | ||
| + | |- | ||
| + | | 9 | ||
| + | | Upper Cover | ||
| + | |- | ||
| + | | 10 | ||
| + | | Back Guard Filter | ||
| + | |- | ||
| + | | 11 | ||
| + | | Side Panel Parts | ||
| + | |- | ||
| + | | 12 | ||
| + | | PFC Inductance | ||
| + | |- | ||
| + | | 13 | ||
| + | | Separate Plate Assy | ||
| + | |- | ||
| + | | 14 | ||
| + | | Valve Cover | ||
| + | |- | ||
| + | | 15 | ||
| + | | Sensor Mounting Plate | ||
| + | |- | ||
| + | | 16 | ||
| + | | Handle | ||
| + | |- | ||
| + | | 17 | ||
| + | | Baffle | ||
| + | |- | ||
| + | | 18 | ||
| + | | Fixed Board | ||
| + | |- | ||
| + | | 19 | ||
| + | | Tube Electric Heater | ||
| + | |- | ||
| + | | 20 | ||
| + | | Condenser Assy | ||
| + | |- | ||
| + | | 21 | ||
| + | | Pipe Assy | ||
| + | |- | ||
| + | | 22 | ||
| + | | Outlet Tube Assy | ||
| + | |- | ||
| + | | 23 | ||
| + | | Electric Expansion Valve Assy | ||
| + | |- | ||
| + | | 24 | ||
| + | | Electromagnetic Coil A | ||
| + | |- | ||
| + | | 25 | ||
| + | | Electromagnetic Coil B | ||
| + | |- | ||
| + | | 26 | ||
| + | | Electromagnetic Coil C | ||
| + | |- | ||
| + | | 27 | ||
| + | | 1/4 Stop Valve Assy | ||
| + | |- | ||
| + | | 28 | ||
| + | | 3/8 Stop Valve Assy | ||
| + | |- | ||
| + | | 29 | ||
| + | | Base Parts | ||
| + | |- | ||
| + | | 30 | ||
| + | | Mounting Plate | ||
| + | |- | ||
| + | | 31 | ||
| + | | Compressor | ||
| + | |- | ||
| + | | 32 | ||
| + | | Noise Insulation Cotton | ||
| + | |- | ||
| + | | 33 | ||
| + | | Noise Insulation Cotton | ||
| + | |- | ||
| + | | 34 | ||
| + | | Electric Heating Belt | ||
| + | |- | ||
| + | | 35 | ||
| + | | Noise Insulation Cotton | ||
| + | |- | ||
| + | | 36 | ||
| + | | Noise Insulation Cotton | ||
| + | |- | ||
| + | | 37 | ||
| + | | Suction Tube Assy | ||
| + | |- | ||
| + | | 38 | ||
| + | | Discharge Tube Assy | ||
| + | |- | ||
| + | | 39 | ||
| + | | 4-Way Valve Assy | ||
| + | |- | ||
| + | | 40 | ||
| + | | Mounting Plate | ||
| + | |- | ||
| + | | 41 | ||
| + | | Driver Board | ||
| + | |- | ||
| + | | 42 | ||
| + | | Outdoor Main Control Board | ||
| + | |- | ||
| + | | 43 | ||
| + | | Filter Board | ||
| + | |- | ||
| + | | 44 | ||
| + | | Electric Joint Box Assy | ||
| + | |- | ||
| + | | 45 | ||
| + | | Capacitor | ||
| + | |- | ||
| + | | 46 | ||
| + | | Radiator | ||
| + | |- | ||
| + | | 47 | ||
| + | | Connect Terminal Panel | ||
| + | |- | ||
| + | | 48 | ||
| + | | Power Terminal Panel | ||
| + | |- | ||
| + | | 49 | ||
| + | | Clamp | ||
| + | |- | ||
| + | | 50 | ||
| + | | Clamp | ||
| + | |- | ||
| + | | 51 | ||
| + | | Temperature Sensor | ||
| + | |- | ||
| + | | 52 | ||
| + | | Temperature Sensor | ||
| + | |- | ||
| + | | 53 | ||
| + | | Temperature Sensor | ||
| + | |- | ||
| + | | 54 | ||
| + | | 4-Way Valve | ||
|- | |- | ||
|} | |} | ||
| + | == PCB Printed Diagram == | ||
| + | [[File:MP-ODU-24K-PCB.jpg|right|thumb|500px|AMSCI4H424 PCB Printed Diagram]] | ||
Latest revision as of 14:44, 30 September 2019
AMSCI4H4S24 is the 24,000 Btu outdoor unit of Multi Plus Series.
Wiring Diagram
Exploded View and Parts List
| Number | Part Description |
|---|---|
| 1 | Fan Guard |
| 2 | Front Panel |
| 3 | Left Guard Filter |
| 4 | Mounting Plate |
| 5 | Welding Hex Nuts |
| 6 | Propeller Fan |
| 7 | Fan Motor |
| 8 | Motor Bracket |
| 9 | Upper Cover |
| 10 | Back Guard Filter |
| 11 | Side Panel Parts |
| 12 | PFC Inductance |
| 13 | Separate Plate Assy |
| 14 | Valve Cover |
| 15 | Sensor Mounting Plate |
| 16 | Handle |
| 17 | Baffle |
| 18 | Fixed Board |
| 19 | Tube Electric Heater |
| 20 | Condenser Assy |
| 21 | Pipe Assy |
| 22 | Outlet Tube Assy |
| 23 | Electric Expansion Valve Assy |
| 24 | Electromagnetic Coil A |
| 25 | Electromagnetic Coil B |
| 26 | Electromagnetic Coil C |
| 27 | 1/4 Stop Valve Assy |
| 28 | 3/8 Stop Valve Assy |
| 29 | Base Parts |
| 30 | Mounting Plate |
| 31 | Compressor |
| 32 | Noise Insulation Cotton |
| 33 | Noise Insulation Cotton |
| 34 | Electric Heating Belt |
| 35 | Noise Insulation Cotton |
| 36 | Noise Insulation Cotton |
| 37 | Suction Tube Assy |
| 38 | Discharge Tube Assy |
| 39 | 4-Way Valve Assy |
| 40 | Mounting Plate |
| 41 | Driver Board |
| 42 | Outdoor Main Control Board |
| 43 | Filter Board |
| 44 | Electric Joint Box Assy |
| 45 | Capacitor |
| 46 | Radiator |
| 47 | Connect Terminal Panel |
| 48 | Power Terminal Panel |
| 49 | Clamp |
| 50 | Clamp |
| 51 | Temperature Sensor |
| 52 | Temperature Sensor |
| 53 | Temperature Sensor |
| 54 | 4-Way Valve |