Difference between revisions of "AMXEC4H4S12"
From Technical Support Wiki
(Created page with "AMXEC4H4S12 is the 12,000 Btu cassette type indoor unit of ''Multi Plus Series''. right|thumb|''Multi Plus'' evaporator (12k) == Remot...") |
|||
(One intermediate revision by the same user not shown) | |||
Line 64: | Line 64: | ||
|} | |} | ||
== Wiring Diagram == | == Wiring Diagram == | ||
− | [[File:MP-Cassette-Type-IDU-WD.png|none|thumb|500px| | + | [[File:MP-Cassette-Type-IDU-WD.png|none|thumb|500px|AMXEC4H4S12 Wiring Diagram]] |
− | + | == Exploded View and Parts List == | |
+ | [[File:MP-CT-12K-EV.png|left|thumb|500px|AMXEC4H4S12 Exploded View]] | ||
+ | {| class="wikitable" | ||
+ | ! Number | ||
+ | ! Part Description | ||
+ | |- | ||
+ | | 1 | ||
+ | | Air Guiding Plate | ||
+ | |- | ||
+ | | 2 | ||
+ | | Water Drain Plate | ||
+ | |- | ||
+ | | 3 | ||
+ | | Centrifugal Fan Blade | ||
+ | |- | ||
+ | | 4 | ||
+ | | DC Motor | ||
+ | |- | ||
+ | | 5 | ||
+ | | Fixed Board | ||
+ | |- | ||
+ | | 6 | ||
+ | | Evaporator Assy | ||
+ | |- | ||
+ | | 7 | ||
+ | | Special Tapping Screws | ||
+ | |- | ||
+ | | 8 | ||
+ | | Fan Volute Assy | ||
+ | |- | ||
+ | | 9 | ||
+ | | Fixed Board | ||
+ | |- | ||
+ | | 10 | ||
+ | | Shell Parts | ||
+ | |- | ||
+ | | 11 | ||
+ | | Electric Box Assy | ||
+ | |- | ||
+ | | 12 | ||
+ | | Clamp | ||
+ | |- | ||
+ | | 13 | ||
+ | | Clamp | ||
+ | |- | ||
+ | | 14 | ||
+ | | Clamp | ||
+ | |- | ||
+ | | 15 | ||
+ | | Insulative Spacer Block | ||
+ | |- | ||
+ | | 16 | ||
+ | | Supporting Leg | ||
+ | |- | ||
+ | | 17 | ||
+ | | Indoor Main Control Board | ||
+ | |- | ||
+ | | 18 | ||
+ | | Wire Terminal Board | ||
+ | |- | ||
+ | | 19 | ||
+ | | Electric Box Cover | ||
+ | |- | ||
+ | | 20 | ||
+ | | Rubber Ring | ||
+ | |- | ||
+ | | 21 | ||
+ | | Over Clamp | ||
+ | |- | ||
+ | | 22 | ||
+ | | Water Pipe | ||
+ | |- | ||
+ | | 23 | ||
+ | | Fixed Board | ||
+ | |- | ||
+ | | 24 | ||
+ | | Rubber Cushion | ||
+ | |- | ||
+ | | 25 | ||
+ | | Water Position Switch | ||
+ | |- | ||
+ | | 26 | ||
+ | | Rubber Cushion | ||
+ | |- | ||
+ | | 27 | ||
+ | | Mounting Plate | ||
+ | |- | ||
+ | | 28 | ||
+ | | Pump Motor | ||
+ | |- | ||
+ | | 29 | ||
+ | | Hexagon Nuts | ||
+ | |- | ||
+ | | 30 | ||
+ | | Temperature Sensor | ||
+ | |- | ||
+ | | 31 | ||
+ | | Temperature Sensor | ||
+ | |- | ||
+ | |} | ||
== PCB Printed Diagram == | == PCB Printed Diagram == | ||
− | [[File:MP-Cassette-Type-IDU-PCB.png|right|thumb|500px| | + | [[File:MP-Cassette-Type-IDU-PCB.png|right|thumb|500px|AMXEC4H4S12 PCB Printed Diagram]] |
Latest revision as of 15:43, 30 September 2019
AMXEC4H4S12 is the 12,000 Btu cassette type indoor unit of Multi Plus Series.
Remote Control
# | Name | Description |
1 | ON/OFF | Press to start or stop operation. |
2 | MODE | Press to select operation mode (Auto/Cool/Dry/Fan/Heat). |
3 | FAN | Used to select the fan speed in sequence: auto, high, medium, or low. |
4 | ROOM TEMPERATURE SETTING | Press to raise the temperature setting. Can also be used to adjust the timer and adjust the current time. |
5 | ROOM TEMPERATURE SETTING | Press to lower the temperature setting. Can also be used to adjust the timer and adjust the current time. |
6 | SMART | Adjust smart settings. |
7 | SWING | Used to stop or start vertical adjustment louver swinging and set the desired up/down airflow direction. |
8 | SLEEP | Used to set or cancel Sleep Mode operation. |
9 | IFEEL | Used to set IFEEL operation. |
10 | CLOCK | Used to set the current time. |
11 | TIMER ON | Used to turn the timer function on. |
12 | TIMER OFF | Used to turn the timer function off. |
13 | SUPER | Used to start/stop the super cool/heat function. (Super cooling operates at high fan speed with a default 64 F temperature setting. Super heating operates at high fan speed with a default 89 F temperature setting.) |
14 | DIMMER | Pressing this button will dim the display on the indoor unit. Pressing any button will reverse the dimmer. |
Wiring Diagram
Exploded View and Parts List
Number | Part Description |
---|---|
1 | Air Guiding Plate |
2 | Water Drain Plate |
3 | Centrifugal Fan Blade |
4 | DC Motor |
5 | Fixed Board |
6 | Evaporator Assy |
7 | Special Tapping Screws |
8 | Fan Volute Assy |
9 | Fixed Board |
10 | Shell Parts |
11 | Electric Box Assy |
12 | Clamp |
13 | Clamp |
14 | Clamp |
15 | Insulative Spacer Block |
16 | Supporting Leg |
17 | Indoor Main Control Board |
18 | Wire Terminal Board |
19 | Electric Box Cover |
20 | Rubber Ring |
21 | Over Clamp |
22 | Water Pipe |
23 | Fixed Board |
24 | Rubber Cushion |
25 | Water Position Switch |
26 | Rubber Cushion |
27 | Mounting Plate |
28 | Pump Motor |
29 | Hexagon Nuts |
30 | Temperature Sensor |
31 | Temperature Sensor |