Difference between revisions of "ABXCI4H4S12"

From Technical Support Wiki
Jump to: navigation, search
(Created page with "ABXCI4H4S12 is the 21 SEER 12,000 Btu outdoor unit of ''Blue Series 3''. right|thumb|''Blue Series 3'' condenser (12k) == Wiring Diagram == File...")
 
 
(One intermediate revision by the same user not shown)
Line 13: Line 13:
 
|-
 
|-
 
| 2  
 
| 2  
| Terminal of Reactor
+
| Terminal of Reactor (optional)
 
|-
 
|-
 
| 3  
 
| 3  
| Terminal of Reactor
+
| Terminal of Neutral Wire, connect to the terminal panel 1(N)
 
|-
 
|-
 
| 4  
 
| 4  
| Terminal of Signal Wire to Terminal Block
+
| Terminal of Live Wire, connect to the terminal panel 2(L)
 
|-
 
|-
 
| 5  
 
| 5  
| Terminal of Neutral Wire to Terminal Block
+
| Terminal of Signal Wire, connect to the terminal panel 3(SI)
 
|-
 
|-
 
| 6
 
| 6
| Terminal of Neutral Wire to Terminal Block
+
| Terminal of AC Fan
 
|-
 
|-
 
| 7  
 
| 7  
Line 31: Line 31:
 
|-
 
|-
 
| 8  
 
| 8  
| Terminal of AC Fan
+
| Heater Terminal
 
|-
 
|-
 
| 9
 
| 9
Line 37: Line 37:
 
|-
 
|-
 
| 10  
 
| 10  
 +
| Terminal of DC Fan
 +
|-
 +
| 11
 
| Terminal of Electronic Expansion Valve
 
| Terminal of Electronic Expansion Valve
 
|-
 
|-
| 11
+
| 12
 
|  Outdoor Ambient Temperature Sensor
 
|  Outdoor Ambient Temperature Sensor
 
|-
 
|-
| 12
+
| 13
 
| Outdoor Pipe Temperature Sensor
 
| Outdoor Pipe Temperature Sensor
 
|-
 
|-
| 13
+
| 14
 
| Compressor Discharge Temperature Sensor
 
| Compressor Discharge Temperature Sensor
 
|-
 
|-
| 14
+
| 15
 
| Terminal of Compressor Overload Protector
 
| Terminal of Compressor Overload Protector
 
|-
 
|-
| 15
+
| 16
 
| Over Pressure Sensor
 
| Over Pressure Sensor
 
|-
 
|-
| 16
+
| 17
| Terminal of DC Fan
+
| DRED Function
 
|}
 
|}
 
<br />
 
<br />
Line 62: Line 65:
  
 
== Exploded View and Parts List ==
 
== Exploded View and Parts List ==
[[File:Blue2-12k-ODU-EV.png|left|thumb|500px|ABSCI4H4S12 Exploded View]]
+
[[File:Blue3-12k-ODU-EV.png|left|thumb|500px|ABXCI4H4S12 Exploded View]]
 
{| class="wikitable"
 
{| class="wikitable"
 
! Number
 
! Number
Line 101: Line 104:
 
|-
 
|-
 
| 12
 
| 12
| Pipe Assy
+
| 4-Way Valve Assembly
 
|-
 
|-
 
| 13
 
| 13
| Compressor
+
| 4-Way Valve Coil
 
|-
 
|-
 
| 14
 
| 14
| Compressor Connect Wire
+
| 4-Way Valve
 
|-
 
|-
 
| 15  
 
| 15  
| Capillary Assembly
+
| Compressor
 
|-
 
|-
 
| 16
 
| 16
| 2-way Valve
+
| Compressor Connect Wire
 
|-
 
|-
 
| 17  
 
| 17  
| 3-Way Valve
+
| Capillary Assembly
 
|-
 
|-
 
| 18
 
| 18
| Right Side Board
+
| 1/4" 2-Way Valve
 
|-
 
|-
 
| 19  
 
| 19  
| Wiring Distribution Cover Assy
+
| 3/8" 3-Way Valve
 
|-
 
|-
 
| 20  
 
| 20  
| Connecting Board
+
| Right Side Board
 
|-
 
|-
 
| 21
 
| 21
| Wire Terminal Board
+
| Wiring Distribution Cover Assy
 
|-
 
|-
 
| 22
 
| 22
| Electric Box
+
| Fixed Board
 
|-
 
|-
 
| 23
 
| 23
| Outdoor Main Control Board Component<sup>1</sup>
+
| Connecting Board
 
|-
 
|-
 
| 24
 
| 24
 +
| Wire Terminal Board
 +
|-
 +
| 25
 +
| Electric Box
 +
|-
 +
| 26
 +
| Outdoor Main Control Board Component
 +
|-
 +
| 27
 
| Electric Box Cover
 
| Electric Box Cover
 
|-
 
|-
| 25
+
| 28
 
| Temperature Sensor
 
| Temperature Sensor
 
|-
 
|-
| 26
+
| 29
 
| Temperature Sensor
 
| Temperature Sensor
 
|-
 
|-
| 27
+
| 30
 
| Temperature Sensor
 
| Temperature Sensor
 
|-
 
|-
| 28
+
| 31
 
| Sensor Mounting Plate
 
| Sensor Mounting Plate
 
|}
 
|}
<sup>1</sup>''ODU control board had a revision in March 2018.''
+
 
  
 
== Piping Sizes ==
 
== Piping Sizes ==

Latest revision as of 13:06, 15 July 2019

ABXCI4H4S12 is the 21 SEER 12,000 Btu outdoor unit of Blue Series 3.

Blue Series 3 condenser (12k)

Wiring Diagram

ABXCI4H4S12 Wiring Diagram

PCB Printed Diagram

ABSXI4H4S12 PCB Diagram
Number Description
1 Terminal of Compressor U/V/W Phase
2 Terminal of Reactor (optional)
3 Terminal of Neutral Wire, connect to the terminal panel 1(N)
4 Terminal of Live Wire, connect to the terminal panel 2(L)
5 Terminal of Signal Wire, connect to the terminal panel 3(SI)
6 Terminal of AC Fan
7 Cool Valve Terminal
8 Heater Terminal
9 4-way Valve Terminal
10 Terminal of DC Fan
11 Terminal of Electronic Expansion Valve
12 Outdoor Ambient Temperature Sensor
13 Outdoor Pipe Temperature Sensor
14 Compressor Discharge Temperature Sensor
15 Terminal of Compressor Overload Protector
16 Over Pressure Sensor
17 DRED Function




Exploded View and Parts List

ABXCI4H4S12 Exploded View
Number Part Name
1 Panel Parts
2 Propeller Fan Blade
3 Fan Motor
4 Motor Supporter Assy
5 Mounting Plate
6 Upper Board
7 Back Guard
8 Condenser Assembly
9 Base Holder Part
10 Clapboard
11 PFC Inductance
12 4-Way Valve Assembly
13 4-Way Valve Coil
14 4-Way Valve
15 Compressor
16 Compressor Connect Wire
17 Capillary Assembly
18 1/4" 2-Way Valve
19 3/8" 3-Way Valve
20 Right Side Board
21 Wiring Distribution Cover Assy
22 Fixed Board
23 Connecting Board
24 Wire Terminal Board
25 Electric Box
26 Outdoor Main Control Board Component
27 Electric Box Cover
28 Temperature Sensor
29 Temperature Sensor
30 Temperature Sensor
31 Sensor Mounting Plate


Piping Sizes

Liquid Side Gas Side
1/4" 3/8"

Accessories