== Model Numbers ==
 +
* FDUM22KXE6F
 +
* FDUM28KXE6F
 +
* FDUM36KXE6F
 +
* FDUM45KXE6F
 +
* FDUM56KXE6F
 +
* FDUM71KXE6F
 +
* FDUM90KXE6F
 +
* FDUM112KXE6F
 +
* FDUM140KXE6F
 +
* FDUM160KXE6F
 +
 +
== Specifications ==
 +
{| class="wikitable"
 +
!scope="col" colspan="2" | Item
 +
!scope="col" | Unit
 +
| FDUM22KXE6F
 +
| FDUM28KXE6F
 +
| FDUM36KXE6F
 +
| FDUM45KXE6F
 +
| FDUM56KXE6F
 +
| FDUM71KXE6F
 +
| FDUM90KXE6F
 +
| FDUM112KXE6F
 +
| FDUM140KXE6F
 +
| FDUM160KXE6F
 +
|-
 +
| colspan="2" | Nominal Cooling Capacity
 +
| kW
 +
| 2.2
 +
| 2.8
 +
| 3.6
 +
| 4.5
 +
| 5.6
 +
| 7.1
 +
| 9.0
 +
| 11.2
 +
| 14.0
 +
| 16.0
 +
|-
 +
| colspan="2" | Nominal Heating Capacity
 +
| kW
 +
| 2.5
 +
| 3.2
 +
| 4.0
 +
| 5.0
 +
| 6.3
 +
| 8.0
 +
| 10.0
 +
| 12.5
 +
| 16.0
 +
| 18.0
 +
|-
 +
| colspan="2" | Power Source
 +
|
 +
| colspan="10" style="text-align: center;" | 1 Phase 220V, 60Hz
 +
|-
 +
| rowspan="2" | Power Consumption
 +
| Cooling
 +
| rowspan="2" | kW
 +
| colspan="5" style="text-align: center;" | 0.10
 +
| colspan="2" style="text-align: center;" | 0.20
 +
| 0.29
 +
| 0.33
 +
| 0.45
 +
|-
 +
| Heating
 +
| colspan="5" style="text-align: center;" | 0.10
 +
| colspan="2" style="text-align: center;" | 0.20
 +
| 0.29
 +
| 0.33
 +
| 0.45
 +
|-
 +
| colspan="2" | Sound Power Level
 +
| dB(A)
 +
| colspan="5" style="text-align: center;" | 60
 +
| colspan="2" style="text-align: center;" | 65
 +
| colspan="3" style="text-align: center;" | ---
 +
|-
 +
| colspan="2" | Sound Pressure Level
 +
| dB(A)
 +
| colspan="5" style="text-align: center;" | Hi: 32 Me: 29 Lo: 26
 +
| colspan="2" style="text-align: center;" | Hi: 33 Me: 29 Lo: 25
 +
| Hi: 38 Me: 36 Lo: 30
 +
| Hi: 40 Me: 34 Lo: 29
 +
| Hi: 40 Me: 35 Lo: 30
 +
|-
 +
| colspan="2" | Exterior Dimensions H x W x D
 +
| mm
 +
| colspan="5" style="text-align: center;" | 280x750x635
 +
| colspan="2" style="text-align: center;" | 280x950x635
 +
| colspan="3" style="text-align: center;" | 280x1370x740
 +
|-
 +
| colspan="2" | Net Weight
 +
| kg
 +
| colspan="5" style="text-align: center;" | 29
 +
| colspan="2" style="text-align: center;" | 34
 +
| colspan="3" style="text-align: center;" | 54
 +
|-
 +
| colspan="2" | Air Flow
 +
| m<sup>3</sup>/min
 +
| colspan="5" style="text-align: center;" | Hi: 10 Me: 9 Lo: 8
 +
| colspan="2" style="text-align: center;" | Hi: 19 Me: 15 Lo: 10
 +
| Hi: 28 Me: 25 Lo: 19
 +
| Hi: 32 Me: 26 Lo: 20
 +
| Hi: 35 Me: 28 Lo: 22
 +
|-
 +
| colspan="2" | Maximum External Static Pressure
 +
| Pa
 +
| colspan="10" style="text-align: center;" | 100
 +
|-
 +
| colspan="2" | Outside Air Intake
 +
|
 +
| colspan="10" style="text-align: center;" | Possible
 +
|-
 +
| colspan="2" | Air Filter
 +
|
 +
| colspan="10" style="text-align: center;" | Filter kit: UM-FL1EF/UM-FL2EF/UM-FL3EF (option)
 +
|-
 +
| colspan="2" | Remote Control (option)
 +
|
 +
| colspan="10" style="text-align: center;" | wired: RC-EX3, RC-E5, RCH-E3 wireless: RCN-KIT4-E2
 +
|-
 +
| colspan="2" | Refrigerant Piping Size
 +
| mm (in)
 +
| colspan="2" style="text-align: center;" | Liquid Line: ⌀6.35 (1/4") Gas Line: ⌀9.52 (3/8")
 +
| colspan="3" style="text-align: center;" | Liquid Line: ⌀6.35 (1/4") Gas Line: ⌀12.7 (1/2")
 +
| colspan="5" style="text-align: center;" | Liquid Line: ⌀9.52 (3/8") Gas Line: ⌀15.88 (5/8")
 +
|-
 +
|}

Latest revision as of 14:30, 5 November 2018

This is the support page for the Duct Connected Low/Middle Static Pressure indoor unit (FDUM) for MHI VRF air conditioners.

Mitsubishi Heavy Industries VRF
Duct Connected Low/Middle Static Pressure (FDUM)
MHI-FDUM-IDU.png
Voltage 220V
Capacities (kW) 2.2-16.0
Heat Pump? Yes

Model Numbers

  • FDUM22KXE6F
  • FDUM28KXE6F
  • FDUM36KXE6F
  • FDUM45KXE6F
  • FDUM56KXE6F
  • FDUM71KXE6F
  • FDUM90KXE6F
  • FDUM112KXE6F
  • FDUM140KXE6F
  • FDUM160KXE6F

Specifications

Item Unit FDUM22KXE6F FDUM28KXE6F FDUM36KXE6F FDUM45KXE6F FDUM56KXE6F FDUM71KXE6F FDUM90KXE6F FDUM112KXE6F FDUM140KXE6F FDUM160KXE6F
Nominal Cooling Capacity kW 2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0 16.0
Nominal Heating Capacity kW 2.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0 18.0
Power Source 1 Phase 220V, 60Hz
Power Consumption Cooling kW 0.10 0.20 0.29 0.33 0.45
Heating 0.10 0.20 0.29 0.33 0.45
Sound Power Level dB(A) 60 65 ---
Sound Pressure Level dB(A) Hi: 32 Me: 29 Lo: 26 Hi: 33 Me: 29 Lo: 25 Hi: 38 Me: 36 Lo: 30 Hi: 40 Me: 34 Lo: 29 Hi: 40 Me: 35 Lo: 30
Exterior Dimensions H x W x D mm 280x750x635 280x950x635 280x1370x740
Net Weight kg 29 34 54
Air Flow m3/min Hi: 10 Me: 9 Lo: 8 Hi: 19 Me: 15 Lo: 10 Hi: 28 Me: 25 Lo: 19 Hi: 32 Me: 26 Lo: 20 Hi: 35 Me: 28 Lo: 22
Maximum External Static Pressure Pa 100
Outside Air Intake Possible
Air Filter Filter kit: UM-FL1EF/UM-FL2EF/UM-FL3EF (option)
Remote Control (option) wired: RC-EX3, RC-E5, RCH-E3 wireless: RCN-KIT4-E2
Refrigerant Piping Size mm (in) Liquid Line: ⌀6.35 (1/4") Gas Line: ⌀9.52 (3/8") Liquid Line: ⌀6.35 (1/4") Gas Line: ⌀12.7 (1/2") Liquid Line: ⌀9.52 (3/8") Gas Line: ⌀15.88 (5/8")