Difference between revisions of "A16CM4H4R18"
From Technical Support Wiki
(8 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
A16CM4H4R18 is the 16 SEER, 18,000 Btu dual zone multi split unit. | A16CM4H4R18 is the 16 SEER, 18,000 Btu dual zone multi split unit. | ||
+ | [[File:Multi-cond.png|thumb|right|Multi Split Condenser]] | ||
+ | == Wiring Diagram== | ||
+ | [[File:Multi-18K-ODU-WD.jpg|none|thumb|500px|A16CM4H4R18 Wiring Diagram]] | ||
+ | == Exploded View and Parts List == | ||
+ | [[File:Multi-18K-ODU-EV.jpg|thumb|500px|A16CM4H4R18 Exploded View]] | ||
+ | {| class="wikitable" | ||
+ | ! Number | ||
+ | ! Part Name | ||
+ | |- | ||
+ | | 1 | ||
+ | | Front Grill | ||
+ | |- | ||
+ | | 2 | ||
+ | | Cabinet | ||
+ | |- | ||
+ | | 3 | ||
+ | | Chassis Sub-Assy | ||
+ | |- | ||
+ | | 4 | ||
+ | | Drainage Joint | ||
+ | |- | ||
+ | | 5 | ||
+ | | Compressor Gasket | ||
+ | |- | ||
+ | | 6 | ||
+ | | Compressor and Fittings | ||
+ | |- | ||
+ | | 7 | ||
+ | | Magnet Coil | ||
+ | |- | ||
+ | | 8 | ||
+ | | 4-Way Valve Assy | ||
+ | |- | ||
+ | | 9 | ||
+ | | Temperature Sensor | ||
+ | |- | ||
+ | | 10 | ||
+ | | Temperature Sensor | ||
+ | |- | ||
+ | | 11 | ||
+ | | Cut-Off Valve | ||
+ | |- | ||
+ | | 12 | ||
+ | | Cut-Off Valve | ||
+ | |- | ||
+ | | 13 | ||
+ | | Block | ||
+ | |- | ||
+ | | 14 | ||
+ | | Handle Assy | ||
+ | |- | ||
+ | | 15 | ||
+ | | Electric Expand Valve Fitting | ||
+ | |- | ||
+ | | 16 | ||
+ | | Electric Expand Valve Fitting | ||
+ | |- | ||
+ | | 17 | ||
+ | | PFC Inductance | ||
+ | |- | ||
+ | | 18 | ||
+ | | Clapboard Sub-Assy | ||
+ | |- | ||
+ | | 19 | ||
+ | | Temperature Sensor | ||
+ | |- | ||
+ | | 20 | ||
+ | | Rear Grill | ||
+ | |- | ||
+ | | 21 | ||
+ | | Condenser Assy | ||
+ | |- | ||
+ | | 22 | ||
+ | | Top Cover | ||
+ | |- | ||
+ | | 23 | ||
+ | | Motor Support Sub-Assy | ||
+ | |- | ||
+ | | 24 | ||
+ | | Left Side Plate | ||
+ | |- | ||
+ | | 25 | ||
+ | | Electric Box Assy | ||
+ | |- | ||
+ | | 26 | ||
+ | | Fan Motor | ||
+ | |- | ||
+ | | 27 | ||
+ | | Axial Flow Fan | ||
+ | |} | ||
+ | == Piping Sizes == | ||
+ | {| class="wikitable" | ||
+ | ! Liquid Side | ||
+ | ! Gas Side | ||
+ | ! Evaporators | ||
+ | |- | ||
+ | | 1/4" | ||
+ | | 3/8" | ||
+ | | A16EM4H4R09 <br />A16EM4H4R12 | ||
+ | |- | ||
+ | | 1/4" | ||
+ | | 1/2" | ||
+ | | A16EM4H4R18 | ||
+ | |} | ||
== Malfunction Indicator == | == Malfunction Indicator == | ||
Note: When several malfunctions occur at the same time, they will be displayed in circulation and every malfunction is displayed for 5 seconds. | Note: When several malfunctions occur at the same time, they will be displayed in circulation and every malfunction is displayed for 5 seconds. | ||
Line 431: | Line 535: | ||
* [[Communication Malfunction (Multi ODU)|Communication Malfunction]] | * [[Communication Malfunction (Multi ODU)|Communication Malfunction]] | ||
* [[Compressor Overload/Discharge Protection Malfunction (Multi ODU)|Compressor Overload/Discharge Protection Malfunction]] | * [[Compressor Overload/Discharge Protection Malfunction (Multi ODU)|Compressor Overload/Discharge Protection Malfunction]] | ||
+ | == Accessories == | ||
+ | *[[Wall Bracket (QBR-19.5)]] | ||
+ | *[[Universal Remote (QTH-4000)]] |
Latest revision as of 14:37, 6 May 2014
A16CM4H4R18 is the 16 SEER, 18,000 Btu dual zone multi split unit.
Wiring Diagram
Exploded View and Parts List
Number | Part Name |
---|---|
1 | Front Grill |
2 | Cabinet |
3 | Chassis Sub-Assy |
4 | Drainage Joint |
5 | Compressor Gasket |
6 | Compressor and Fittings |
7 | Magnet Coil |
8 | 4-Way Valve Assy |
9 | Temperature Sensor |
10 | Temperature Sensor |
11 | Cut-Off Valve |
12 | Cut-Off Valve |
13 | Block |
14 | Handle Assy |
15 | Electric Expand Valve Fitting |
16 | Electric Expand Valve Fitting |
17 | PFC Inductance |
18 | Clapboard Sub-Assy |
19 | Temperature Sensor |
20 | Rear Grill |
21 | Condenser Assy |
22 | Top Cover |
23 | Motor Support Sub-Assy |
24 | Left Side Plate |
25 | Electric Box Assy |
26 | Fan Motor |
27 | Axial Flow Fan |
Piping Sizes
Liquid Side | Gas Side | Evaporators |
---|---|---|
1/4" | 3/8" | A16EM4H4R09 A16EM4H4R12 |
1/4" | 1/2" | A16EM4H4R18 |
Malfunction Indicator
Note: When several malfunctions occur at the same time, they will be displayed in circulation and every malfunction is displayed for 5 seconds.
NO. | Malfunction description | LED1 | LED2 | LED3 | LED4 |
0 | Normal stop | off | off | off | off |
1 | Compressor run | on | off | off | off |
2 | Compressor overload protection | blinking | off | off | off |
3 | Discharge protection | off | on | off | off |
4 | Outdoor unit overload protection | on | on | off | off |
5 | High pressure protection | blinking | on | off | off |
6 | Over current protection | off | blinking | off | off |
7 | IMP protection | on | blinking | off | off |
8 | IMP overheating protection | blinking | blinking | off | off |
9 | PFC protection (including PFC overheating protection) | off | off | on | off |
10 | Phase current protection | on | off | on | off |
11 | Over voltage protection | blinking | off | on | off |
12 | Insufficient voltage protection | off | on | on | off |
13 | Start failure | on | on | on | off |
14 | Compressor desynchronizing | blinking | on | on | off |
15 | Compressor phase-lacking protection | off | blinking | on | off |
16 | Compressor phase current detection malfunction | on | blinking | on | off |
17 | Memory chip mistake | blinking | blinking | on | off |
18 | DC power supply short-circuit | off | off | blinking | off |
19 | Defrosting | on | off | blinking | off |
20 | Oil return | blinking | off | blinking | off |
21 | Complete unit frequency restriction protection | off | on | blinking | off |
22 | Complete unit frequency dropping protection | on | on | blinking | off |
23 | Unit A frequency restriction or frequency dropping protection | blinking | on | blinking | off |
24 | Unit B frequency restriction or frequency dropping protection | off | blinking | blinking | off |
25 | Unit C frequency restriction or frequency dropping protection | on | blinking | blinking | off |
26 | Unit D frequency restriction or frequency dropping protection | blinking | blinking | blinking | off |
27 | Outdoor ambient temperature sensor protection | off | off | off | on |
28 | Outdoor tube temperature sensor protection | on | off | off | on |
29 | Discharge temperature sensor protection | blinking | off | off | on |
30 | IPM thermal resistance malfunction | off | on | off | on |
31 | Unit A liquid pipe temperature sensor malfunction | on | on | off | on |
32 | Unit A gas pipe temperature sensor malfunction | blinking | on | off | on |
33 | Unit B liquid pipe temperature sensor malfunction | off | blinking | off | on |
34 | Unit B gas pipe temperature sensor malfunction | on | blinking | off | on |
35 | Unit C liquid pipe temperature sensor malfunction | blinking | blinking | off | on |
36 | Unit C gas pipe temperature sensor malfunction | off | off | on | on |
37 | Unit D liquid pipe temperature sensor malfunction | on | off | on | on |
38 | Unit D gas pipe temperature sensor malfunction | blinking | off | on | on |
39 | Unit A mode conflict | off | on | on | on |
40 | Unit B mode conflict | on | on | on | on |
41 | Unit C mode conflict | blinking | on | on | on |
42 | Unit D mode conflict | off | blinking | on | on |
43 | Communication failure with Unit A | on | blinking | on | on |
44 | Communication failure with Unit B | blinking | blinking | on | on |
45 | Communication failure with Unit C | off | off | blinking | on |
46 | Communication failure with Unit D | on | off | blinking | on |
47 | Unit A freeze protection | blinking | off | blinking | on |
48 | Unit B freeze protection | off | on | blinking | on |
49 | Unit C freeze protection | on | on | blinking | on |
50 | Unit D freeze protection | blinking | on | blinking | on |
51 | Unit A overheating prevention protection | off | blinking | blinking | on |
52 | Unit B overheating prevention protection | on | blinking | blinking | on |
53 | Unit C overheating prevention protection | blinking | blinking | blinking | on |
54 | Unit D overheating prevention protection | off | off | off | blinking |
55 | Unit A communication wire misconnection or expansion valve malfunction | on | off | off | blinking |
56 | Unit B communication wire misconnection or expansion valve malfunction | blinking | off | off | blinking |
57 | Unit C communication wire misconnection or expansion valve malfunction | off | on | off | blinking |
58 | Unit D communication wire misconnection or expansion valve malfunction | on | on | off | blinking |
Common Troubleshooting
The following outline solutions for malfunctions that are either not indicated by the LEDs or cover more than one malfunction number in the above table.
- Capacity Charging Malfunction
- Anti-High Temperature and Overload Malfunction
- Temperature Sensor Malfunction
- Start Failure Malfunction
- Communication Malfunction
- Compressor Overload/Discharge Protection Malfunction