Difference between revisions of "ASREM4H4S12"
From Technical Support Wiki
| (2 intermediate revisions by the same user not shown) | |||
| Line 106: | Line 106: | ||
== Exploded View and Parts List == | == Exploded View and Parts List == | ||
| + | [[File:Serene-12k-IDU-EV.png|left|thumb|500px|ASREM4H4S12 Exploded View]] | ||
| + | {| class="wikitable" | ||
| + | ! Number | ||
| + | ! Part Name | ||
| + | |- | ||
| + | | 1 | ||
| + | | Installation Plate Assy | ||
| + | |- | ||
| + | | 2 | ||
| + | | Baffle | ||
| + | |- | ||
| + | | 3 | ||
| + | | Base Holder Part | ||
| + | |- | ||
| + | | 4 | ||
| + | | Vertical Level Vane | ||
| + | |- | ||
| + | | 5 | ||
| + | | Level Lane | ||
| + | |- | ||
| + | | 6 | ||
| + | | Cross Flow Fan Blade | ||
| + | |- | ||
| + | | 7 | ||
| + | | Bearing | ||
| + | |- | ||
| + | | 8 | ||
| + | | Baffle | ||
| + | |- | ||
| + | | 9 | ||
| + | | Refrigeration System | ||
| + | |- | ||
| + | | 10 | ||
| + | | Motor Guard | ||
| + | |- | ||
| + | | 11 | ||
| + | | Fan Motor | ||
| + | |- | ||
| + | | 12 | ||
| + | | Motor Cover | ||
| + | |- | ||
| + | | 13 | ||
| + | | Remote Controller | ||
| + | |- | ||
| + | | 14 | ||
| + | | Electric Box Cover | ||
| + | |- | ||
| + | | 15 | ||
| + | | Temperature Sensor | ||
| + | |- | ||
| + | | 16 | ||
| + | | Temperature Sensor | ||
| + | |- | ||
| + | | 17 | ||
| + | | Over Clamp | ||
| + | |- | ||
| + | | 18 | ||
| + | | Wire Terminal Board | ||
| + | |- | ||
| + | | 19 | ||
| + | | Electric Box Cover | ||
| + | |- | ||
| + | | 20 | ||
| + | | Electric Joint Box Plate | ||
| + | |- | ||
| + | | 21 | ||
| + | | Indoor Main Control Board Component | ||
| + | |- | ||
| + | | 22 | ||
| + | | Electric Box | ||
| + | |- | ||
| + | | 23 | ||
| + | | Electric Joint Box Plate | ||
| + | |- | ||
| + | | 24 | ||
| + | | Water Pipe Parts | ||
| + | |- | ||
| + | | 25 | ||
| + | | Axis Sheath | ||
| + | |- | ||
| + | | 26 | ||
| + | | Step Motor | ||
| + | |- | ||
| + | | 27 | ||
| + | | Shell | ||
| + | |- | ||
| + | | 28 | ||
| + | | Display Component | ||
| + | |- | ||
| + | | 29 | ||
| + | | Ornamental Part | ||
| + | |- | ||
| + | | 30 | ||
| + | | Panel | ||
| + | |} | ||
Latest revision as of 17:17, 10 November 2017
ASREM4H4S12 is the 17 SEER 12,000 Btu indoor unit of Serene Series.
Remote Control
| # | Name | Description |
| 1 | ON/OFF | Press to start or stop operation. |
| 2 | MODE | Press to select operation mode (Auto/Cool/Dry/Fan/Heat). |
| 3 | FAN | Used to select the fan speed in sequence: auto, high, medium, or low. |
| 4 | ROOM TEMPERATURE SETTING | Press to raise the temperature setting. Can also be used to adjust the timer and adjust the current time. |
| 5 | ROOM TEMPERATURE SETTING | Press to lower the temperature setting. Can also be used to adjust the timer and adjust the current time. |
| 6 | SMART | Adjust smart settings. |
| 7 | SWING | Used to stop or start vertical adjustment louver swinging and set the desired up/down airflow direction. |
| 8 | SLEEP | Used to set or cancel Sleep Mode operation. |
| 9 | IFEEL | Used to set IFEEL operation. |
| 10 | CLOCK | Used to set the current time. |
| 11 | TIMER ON | Used to turn the timer function on. |
| 12 | TIMER OFF | Used to turn the timer function off. |
| 13 | SUPER | Used to start/stop the super cool/heat function. (Super cooling operates at high fan speed with a default 64 F temperature setting. Super heating operates at high fan speed with a default 89 F temperature setting.) |
| 14 | DIMMER | Pressing this button will dim the display on the indoor unit. Pressing any button will reverse the dimmer. |
Wiring Diagram
PCB Printed Diagram
| Number | Description |
|---|---|
| 1 | PG Motor Interface |
| 2 | Room temperature sensor |
| 3 | Pipe temperature sensor |
| 4 | Switch buton |
| 5 | Feedback from PG Motor |
| 6 | Up & down swing |
| 7 | Left & right swing |
| 8 | Wiring control or Wifi interface |
| 9 | Display interface |
| 10 | Protective tube |
Exploded View and Parts List
| Number | Part Name |
|---|---|
| 1 | Installation Plate Assy |
| 2 | Baffle |
| 3 | Base Holder Part |
| 4 | Vertical Level Vane |
| 5 | Level Lane |
| 6 | Cross Flow Fan Blade |
| 7 | Bearing |
| 8 | Baffle |
| 9 | Refrigeration System |
| 10 | Motor Guard |
| 11 | Fan Motor |
| 12 | Motor Cover |
| 13 | Remote Controller |
| 14 | Electric Box Cover |
| 15 | Temperature Sensor |
| 16 | Temperature Sensor |
| 17 | Over Clamp |
| 18 | Wire Terminal Board |
| 19 | Electric Box Cover |
| 20 | Electric Joint Box Plate |
| 21 | Indoor Main Control Board Component |
| 22 | Electric Box |
| 23 | Electric Joint Box Plate |
| 24 | Water Pipe Parts |
| 25 | Axis Sheath |
| 26 | Step Motor |
| 27 | Shell |
| 28 | Display Component |
| 29 | Ornamental Part |
| 30 | Panel |