Latest revision as of 16:33, 10 November 2017
ASREM4H4S09 is the 16 SEER 9,000 Btu indoor unit of Serene Series.
Remote Control
| # | Name | Description |
| 1 | ON/OFF | Press to start or stop operation. |
| 2 | MODE | Press to select operation mode (Auto/Cool/Dry/Fan/Heat). |
| 3 | FAN | Used to select the fan speed in sequence: auto, high, medium, or low. |
| 4 | ROOM TEMPERATURE SETTING | Press to raise the temperature setting. Can also be used to adjust the timer and adjust the current time. |
| 5 | ROOM TEMPERATURE SETTING | Press to lower the temperature setting. Can also be used to adjust the timer and adjust the current time. |
| 6 | SMART | Adjust smart settings. |
| 7 | SWING | Used to stop or start vertical adjustment louver swinging and set the desired up/down airflow direction. |
| 8 | SLEEP | Used to set or cancel Sleep Mode operation. |
| 9 | IFEEL | Used to set IFEEL operation. |
| 10 | CLOCK | Used to set the current time. |
| 11 | TIMER ON | Used to turn the timer function on. |
| 12 | TIMER OFF | Used to turn the timer function off. |
| 13 | SUPER | Used to start/stop the super cool/heat function. (Super cooling operates at high fan speed with a default 64 F temperature setting. Super heating operates at high fan speed with a default 89 F temperature setting.) |
| 14 | DIMMER | Pressing this button will dim the display on the indoor unit. Pressing any button will reverse the dimmer. |
Wiring Diagram
PCB Printed Diagram
| Number | Description |
|---|---|
| 1 | PG Motor Interface |
| 2 | Room temperature sensor |
| 3 | Pipe temperature sensor |
| 4 | Switch buton |
| 5 | Feedback from PG Motor |
| 6 | Up & down swing |
| 7 | Left & right swing |
| 8 | Wiring control or Wifi interface |
| 9 | Display interface |
| 10 | Protective tube |