Difference between revisions of "ATUEM4H1S12"
From Technical Support Wiki
(Created page with "ATUEM4H1S12 is the 18 SEER 12,000 Btu indoor unit of ''Titanium Series''. right|thumb|''Titanium Series'' evaporator (12k) == Remote Control == F...") |
|||
(One intermediate revision by the same user not shown) | |||
Line 106: | Line 106: | ||
== Exploded View and Parts List == | == Exploded View and Parts List == | ||
− | [[File: | + | [[File:Titanium-12k-IDU-EV.png|left|thumb|500px|ATUEM4H1S12 Exploded View]] |
{| class="wikitable" | {| class="wikitable" | ||
! Number | ! Number | ||
Line 121: | Line 121: | ||
|- | |- | ||
| 4 | | 4 | ||
− | | Vertical Level Vane | + | | Vertical Level Vane |
|- | |- | ||
| 5 | | 5 | ||
Line 130: | Line 130: | ||
|- | |- | ||
| 7 | | 7 | ||
− | | Bearing | + | | Bearing |
|- | |- | ||
| 8 | | 8 | ||
Line 142: | Line 142: | ||
|- | |- | ||
| 11 | | 11 | ||
− | | Fan Motor | + | | Fan Motor |
|- | |- | ||
| 12 | | 12 | ||
Line 148: | Line 148: | ||
|- | |- | ||
| 13 | | 13 | ||
− | | Remote Controller | + | | Remote Controller |
|- | |- | ||
| 14 | | 14 | ||
Line 154: | Line 154: | ||
|- | |- | ||
| 15 | | 15 | ||
− | | Temperature Sensor | + | | Temperature Sensor |
|- | |- | ||
| 16 | | 16 | ||
− | | Temperature Sensor | + | | Temperature Sensor |
|- | |- | ||
| 17 | | 17 | ||
− | | Over Clamp | + | | Over Clamp |
|- | |- | ||
| 18 | | 18 | ||
− | | Wire | + | | AC Power Wire |
|- | |- | ||
| 19 | | 19 | ||
− | | | + | | Wire Terminal Board |
|- | |- | ||
| 20 | | 20 | ||
− | | Electric | + | | Electric Box Cover |
|- | |- | ||
| 21 | | 21 | ||
− | | | + | | Electric Joint Box Plate |
|- | |- | ||
| 22 | | 22 | ||
− | | | + | | Indoor Main Control Board Component |
|- | |- | ||
| 23 | | 23 | ||
− | | Electric | + | | Electric Box |
|- | |- | ||
| 24 | | 24 | ||
− | | | + | | Electric Joint Box Plate |
|- | |- | ||
| 25 | | 25 | ||
− | | | + | | Water Pipe Parts |
|- | |- | ||
| 26 | | 26 | ||
− | | | + | | Axis Sheath |
|- | |- | ||
| 27 | | 27 | ||
− | | | + | | Step Motor |
|- | |- | ||
| 28 | | 28 | ||
− | | | + | | Shell |
|- | |- | ||
| 29 | | 29 | ||
Line 199: | Line 199: | ||
|- | |- | ||
| 30 | | 30 | ||
− | | | + | | Ornamental Part |
|- | |- | ||
| 31 | | 31 | ||
− | | | + | | Display Component |
|- | |- | ||
| 32 | | 32 | ||
+ | | Oramental Part | ||
+ | |- | ||
+ | | 33 | ||
| Panel | | Panel | ||
|- | |- | ||
− | | | + | | 34 |
| Display Film | | Display Film | ||
|} | |} |
Latest revision as of 15:06, 10 November 2017
ATUEM4H1S12 is the 18 SEER 12,000 Btu indoor unit of Titanium Series.
Remote Control
# | Name | Description |
1 | ON/OFF | Press to start or stop operation. |
2 | MODE | Press to select operation mode (Auto/Cool/Dry/Fan/Heat). |
3 | FAN | Used to select the fan speed in sequence: auto, high, medium, or low. |
4 | ROOM TEMPERATURE SETTING | Press to raise the temperature setting. Can also be used to adjust the timer and adjust the current time. |
5 | ROOM TEMPERATURE SETTING | Press to lower the temperature setting. Can also be used to adjust the timer and adjust the current time. |
6 | SMART | Adjust smart settings. |
7 | SWING | Used to stop or start vertical adjustment louver swinging and set the desired up/down airflow direction. |
8 | SLEEP | Used to set or cancel Sleep Mode operation. |
9 | IFEEL | Used to set IFEEL operation. |
10 | CLOCK | Used to set the current time. |
11 | TIMER ON | Used to turn the timer function on. |
12 | TIMER OFF | Used to turn the timer function off. |
13 | SUPER | Used to start/stop the super cool/heat function. (Super cooling operates at high fan speed with a default 64 F temperature setting. Super heating operates at high fan speed with a default 89 F temperature setting.) |
14 | DIMMER | Pressing this button will dim the display on the indoor unit. Pressing any button will reverse the dimmer. |
Wiring Diagram
PCB Printed Diagram
Number | Description |
---|---|
1 | PG Motor Interface |
2 | Room temperature sensor |
3 | Pipe temperature sensor |
4 | Switch buton |
5 | Feedback from PG Motor |
6 | Up & down swing |
7 | Left & right swing |
8 | Wiring control or Wifi interface |
9 | Display interface |
10 | Protective tube |
Exploded View and Parts List
Number | Part Name |
---|---|
1 | Installation Plate Assy |
2 | Baffle |
3 | Base Holder Part |
4 | Vertical Level Vane |
5 | Level Vane |
6 | Cross Flow Fan Blade |
7 | Bearing |
8 | Baffle |
9 | Refrigeration System |
10 | Motor Guard |
11 | Fan Motor |
12 | Motor Cover |
13 | Remote Controller |
14 | Electric Box Cover |
15 | Temperature Sensor |
16 | Temperature Sensor |
17 | Over Clamp |
18 | AC Power Wire |
19 | Wire Terminal Board |
20 | Electric Box Cover |
21 | Electric Joint Box Plate |
22 | Indoor Main Control Board Component |
23 | Electric Box |
24 | Electric Joint Box Plate |
25 | Water Pipe Parts |
26 | Axis Sheath |
27 | Step Motor |
28 | Shell |
29 | Ornamental Part |
30 | Ornamental Part |
31 | Display Component |
32 | Oramental Part |
33 | Panel |
34 | Display Film |